# Wavin Sentio Connect

An event-driven Python client for the **Wavin Sentio** floor heating controller over Modbus TCP,
built on [modbus_event_connect](https://github.com/HairingX/modbus_event_connect).

The register map is complete for the location, all 16 rooms and all 64 peripheral slots,
modelled from the official Sentio Modbus manual. Connecting finds out which rooms and
peripherals your installation actually has; you subscribe to the values you care about and are
told when one changes - with its quality, so "offline", "no reading" and a real value never look
alike.

## Installation

```bash
pip install wavin-sentio-connect
```

## Enabling Modbus on the controller

Modbus is **disabled by default**. Enable it from a Sentio Display:

`System | Installer settings | Modbus configuration | Modbus TCP`

The controller restarts afterwards. It uses DHCP; its hostname is
`Wavin Sentio CCU#[last four digits of the serial number]`.

## Usage

```python
import asyncio
from wavin_sentio_connect import RoomPointKey, create_client, room_key, rooms

def on_change(key, old, new):
    print(f"{key}: {new.value} ({new.quality.name})")

async def main():
    client = create_client("<device-ip>")
    await client.connect()              # finds the installed rooms and peripherals

    for room in rooms(client):
        print(room.number, room.name, "dummy" if room.is_dummy else "")
        client.subscribe(room_key(room.number, RoomPointKey.TEMP_AIR_CURRENT), on_change)

    while True:                         # you own the clock; the library owns the plan
        await client.poll()      # reads only what is due - free when nothing is
        await asyncio.sleep(1)

asyncio.run(main())
```

When `connect()` returns, `client.points` holds exactly what this installation has - a room that
was never set up is not there, so nothing is built for it. Nor is what the controller says a
room lacks: a dummy room ("no thermostat or sensor installed") has no temperature, humidity or
dew point, and a room not associated with radiators, underfloor heating, drying, thermal
integration or ventilation has no state or blocking source for it. `rooms(client)` and
`peripherals(client)` describe the installation from values already read, with no extra
requests.

Every value is a `DataValue`: `value`, `quality` and `timestamp` (UTC).

| Quality | Meaning |
|---|---|
| `GOOD` | the controller answered with a valid value |
| `NO_DATA` | it answered "no reading" - a missing sensor, an unconfigured limit, a wired peripheral's signal strength |
| `OFFLINE` | the register exists but what is behind it is not answering |
| `STALE` | the last read failed; the value is the last good one |

## How often values are read

Every point has a poll rate, and the library reads it when it is due:

| Poll rate | Default | Sentio uses it for |
|---|---|---|
| `FAST` | 10 s | room states and blocking sources |
| `MEDIUM` | 30 s | temperatures, humidity, dew point |
| `SLOW` | 60 s | settings |
| `RARE` | 15 min | peripheral signal strength |
| `STATIC` | at connect | versions, serial numbers, names, room types |

Override any of them, or a single key:

```python
from modbus_event_connect import PollRate
client.set_poll_interval(PollRate.FAST, 5)
client.set_poll_interval("room_4_temp_air_current", 2)
await client.refresh(PollRate.STATIC)        # re-read the static values now
```

Only what something wants is read: a subscriber, or `client.set_polling(key)`.

## Writing

```python
await client.write(room_key(1, RoomPointKey.TEMP_AIR_TARGET), 21.5)
await client.write(room_key(1, RoomPointKey.LOCK), RoomLock.HOTEL)   # LOCKED / HOTEL / UNLOCKED
```

- A value of the wrong type is a type error before the program runs: the lock takes a
  `RoomLock`, a temperature a `float`.
- A value is also checked before anything is sent: its range, its states, and the controller's
  "no reading" sentinel, which could never be read back.
- Writes are sent in order. Tapping + five times sends the first value and the last, not all
  five.
- The written point is read back, so subscribers see what the controller holds rather than what
  was asked for. A write that changes the rooms' regulated targets - vacation, standby, a room's
  setpoint, mode or preset - reads those targets again too.
- The controller answers `SERVER_DEVICE_BUSY` (`0x06`) while it stores a change; the manual says
  such a request "shall be repeated again", and the library does, with backoff.
- `client.status(Status.WRITE_PENDING)` - which `client.subscribe_status` follows - is true from
  the moment a write is asked for until the last one has finished.

For monitoring only, create the client read-only; every write is then refused before it reaches
the controller:

```python
client = create_client("<device-ip>", read_only=True)
```

## Alarms

Every alarm and warning the manual documents for the location, the rooms and the peripherals is
a key: `system_warning`, `system_error`, and per room and peripheral `..._warning`,
`..._error`, `..._low_battery` and `room_{n}_peripheral_lost` / `peripheral_{n}_lost`.

The manual describes the location's two bits as covering the whole system ("A problem is
pending in whole system"). Those two are always read at the `FAST` rate; when either changes,
every alarm someone subscribes to is read at once. Each alarm is also read by itself at the
`RARE` rate, in case a controller does not reflect it in the system's bits.

## Sharing a connection

To put the controller on a connection the host already owns - a gateway shared with other
devices - use `create_client_on`:

```python
from modbus_event_connect.modbus import ModbusTcpConnection
from wavin_sentio_connect import create_client_on

connection = ModbusTcpConnection("<device-ip>")
client = create_client_on(connection, unit_id=1)
```

The client is asynchronous end to end - no threads, nothing that blocks the event loop - and
owns no timer: the application calls `poll()` from its own loop.

## Keys and addressing

Every point has its key in `LocationPointKey`, `RoomPointKey` or `PeripheralPointKey`, with the
type of its value. A location point's is its whole key; a room's or a peripheral's becomes one
with the instance:

```python
from wavin_sentio_connect import ROOM, LocationPointKey, RoomPointKey, room_key

client.value(LocationPointKey.VACATION_ENABLE)               # key "vacation_enable"
for n in client.instances(ROOM):                             # the rooms this installation has
    client.value(room_key(n, RoomPointKey.TEMP_AIR_CURRENT))  # key "room_4_temp_air_current"
    client.value(room_key(n, RoomPointKey.STATE))             # a RoomState, such as HEATING
```

A room point's key is the same in every room, so code that handles
`RoomPointKey.TEMP_AIR_CURRENT` once handles it in all of them; `RoomPointKey.all()` lists them.
`UNITS` is every unit a Sentio point has. Key strings never change; new points only add keys.

A state reads as its member of the enum the manual's values give: `RoomState`, `BlockingSource`,
`RoomType`, `RoomMode`, `RoomModeOverride`, `TemperaturePreset`, `RoomLock`, `HeatingCoolingMode`,
`HeatingCoolingModeOverride`, `DeviceType`, `ModbusMode`, `UpdateMode` or `PeripheralType`, and is
written as one. A number the manual does not name reads as `NO_DATA`, and the value's `.raw` holds
the number the controller sent. Standby, vacation and daylight saving, which the manual gives as
0 and 1, are `bool`; their "no value", 255, reads as `NO_DATA` too.

The model is in [`_model.py`](src/wavin_sentio_connect/_model.py); every key is declared there
with its address and encoding.

The manual's "Modbus Address" column holds the addresses themselves, so its numbers are used unchanged:

| Object | Base | Instances |
|---|---|---|
| Location | `0` | one |
| Room *N* | `N * 100` | 1–16 |
| Peripheral *N* | `51100 + N * 100` | 1–64 |

Peripheral slots are **not stable identities** - the controller reorders them when peripherals
are learned or unlearned. Use `peripheral_{n}_serial_number` to recognise a device, and
`peripheral_{n}_owner` (`0` = location, `1`–`16` = room) to find the room it belongs to.

Two room values are easy to confuse: `room_{n}_temp_air_target` is the user's setting, and
`room_{n}_temp_air_target_active` is the target the controller is regulating to right now -
different under standby, vacation or a schedule.

## Documentation

- [`docs/sentio-modbus-reference.md`](docs/sentio-modbus-reference.md) - the protocol: register
  tables, data types, error handling, enumerations.
- [`docs/sentio-registers.csv`](docs/sentio-registers.csv) - all 344 documented registers, one
  row each.

## Known gaps

- Only the location, room and peripheral objects are modelled. Outdoor, DHW, ITC, HCC, buffer
  tank, ventilation and dehumidifier objects are documented in the CSV but not yet wired.

## Disclaimer

Wavin Sentio Connect is provided "as is", without warranty of any kind. The authors and
contributors are not responsible for any damage or data loss that may occur from using this
library. Users are solely responsible for ensuring the proper and safe operation of their
Modbus devices.