UVEX Response File Configuration

Configuration Type: Public v1.0 configuration. Identical to response_files_v0.8.1.json except that THROUGHPUT_SCALE_FACTOR is 0.8 rather than 1.0, de-rating the FUV, NUV and LSS bandpasses by 20% for public release.

UVEX Overview

EntryDescriptionTypeSourceValue
EPDEntrance Pupil Diameter (cm)By designOptical Model75
N_PIXELSNumber of pixels along each edge of the 4k x 4k detectorsBy DesignCMOS Description4096
PIXEL_UMUVEX physical pixel size (microns)By DesignCMOS Description10
PLATE_SCALEUVEX Imager Plate Scale (arcsec / pixel)By DesignOptical Design1.03
SPEC_PLATE_SCALEUVEX LSS Plate Scale (arcsec / pixel)By DesignOptical Design0.8
NPIX_IMGNumber of effective pixels in the imager photometric aperture for a 2-arcsec FWHM PSF. Sets how many pixels of dark current and read noise enter the imaging SNR.modeluvex_mission_v0.8.110.15
NPIX_LSSNumber of effective vertical pixels in the LSS spectral extraction for a 2-arcsec FWHM PSF. Sets how many pixels of dark current and read noise enter the spectroscopic SNR, before scaling by the slit width and spectral resolution.modeluvex_mission_v0.8.13
LSS_SLIT_THROUGHPUTFraction of a point source's flux that passes through the LSS slit, applied as a scalar multiplier on the LSS throughput. Value for a Gaussian PSF centered on the 2-arcsec slit, using the v0.8.1 ETC's 2.25-arcsec LSS PSF HPD.modeluvex_mission_v0.8.10.6944
THROUGHPUT_SCALE_FACTORScalar multiplier applied to the FUV, NUV and LSS bandpasses (including the LSS Lyman-alpha response) after every wavelength-dependent component has been combined. 1.0 leaves the modelled throughput as-is; a value below 1.0 de-rates the whole response to cover end-to-end losses that the individual component curves do not capture.processing choiceuvex_response0.8
vignetting_methodHow the 2D vignetting map is reduced to a single scalar throughput factor applied to the bandpass. 'min' takes the minimum throughput over the field of viewprocessing choiceuvex_responsemin
nuv_filter_toggleWhether to apply the standalone nuv_filter transmission on top of the NUV detector QE in the NUV bandpassprocessing choiceuvex_responseTrue

UVEX Performance Estimates

EntryDescriptionTypeSourceValue
geometry_slit_lengthUVEX LSS slit length (arcsec)By DesignInstrument Design3600
geometry_slit_widthUVEX LSS slit width (arcsec)By DesignInstrument Design2
geometry_slit_xyUVEX LSS slit position relative to boresight (x,y in arcsec)By DesignInstrument Design12600,0
geometry_im_gap_xGap between imager detectors in the X direction (mm)By DesignInstrument Design4.05
geometry_im_gap_yGap between imager detectors in the Y direction (mm)By DesignInstrument Design2.55
geometry_lss_gap_xGap between LSS detectors in the X direction (mm)By DesignInstrument Design0.616
geometry_lss_xy1Position of the LSS-short detector in the LSS plane (x,y in mm)By DesignInstrument Design-5.874,0.0
opticsJPL 24 nm MgF2 / Al mirror coating reflectivity modelmodeljpl_24nm_mgf2_aloptics/response_files/optics_jpl_24nmMgF2Al_model.dat
fuv_detectorJPL 7-layer coating with a band center at 150 nm, dated 2025-05-22modeljpl_150nmcenter_detector_20250522fuv_detector/response_files/fuv_detector_150nmcenter_detector_20250522.dat
nuv_detectorJPL single-layer HfO2 anti-reflection coatingmodeljpl_single_layer_HfO2nuv_detector/response_files/nuv_detector_jpl_single_layer_HfO2.dat
nuv_filterStandalone Materion NUV bandpass filter transmission, ported from v0.8.1 of uvex-mission for benchmarking; applied on top of the NUV detector QEmodelmaterionnuv_filter/response_files/nuv_filter_materion.dat
dichroicActon 180-nm split dichroic model with 10 mm fused silica substrate, AOI-weighted average over 20-40 degree angles of incidencemodelacton_180_dichroic_model_aoi_averagereflection: dichroic/response_files/dichroic_A180_model_reflection.dat
transmission: dichroic/response_files/dichroic_A180_model_transmission.dat
lss_blazeLSS grating blaze / first-order diffraction efficiency, ported from v0.8.1 uvex-mission (zeiss spectrometer setup)modelzeisslss_blaze/response_files/lss_blaze_zeiss.dat
lss_detectorLSS spectrometer detector response (graded-overcoat tapered QE, detector coating and QE combined), ported from v0.8.1 uvex-mission; 'response' is the nominal curve and 'lyman' the Lyman-alpha-specific responsemodelgraded_overcoat_00nmresponse: lss_detector/response_files/lss_detector_graded_overcoat.dat
lyman: lss_detector/response_files/lss_detector_graded_overcoat_lyman.dat
lss_dispersionLSS wavelength dispersion / resolution mapping (WAVE, YPOS, DISPERSION nm/pix, SLIT WIDTH, RESOLUTION), stored as a verbatim pass-through of the v0.8.1 uvex-mission file for downstream wavelength-solution use; not a multiplicative bandpass componentmodelUVEXS_Spectral_Resolution_R2000 (zeiss / R2000 setup)lss_dispersion/response_files/lss_dispersion_R2000.txt
contamination_fuvContamination transmission losses along the FUV optical path (OTA mirrors, dichroic, detector surface) at end of life, ported from the v0.8.1 uvex-mission model: exp(-absorption_coeff * effective_thickness)modeluvex_mission_v0.8.1contamination/response_files/contamination_v0.8.1_fuv_eol.dat
contamination_nuvContamination transmission losses along the NUV optical path (OTA mirrors, dichroic, detector surface) at end of life, ported from the v0.8.1 uvex-mission model: exp(-absorption_coeff * effective_thickness)modeluvex_mission_v0.8.1contamination/response_files/contamination_v0.8.1_nuv_eol.dat
contamination_lssContamination transmission losses along the LSS optical path (OTA + relay mirrors, grating, detector surface) at end of life, ported from the v0.8.1 uvex-mission model: exp(-absorption_coeff * effective_thickness)modeluvex_mission_v0.8.1contamination/response_files/contamination_v0.8.1_lss_eol.dat
vignetting_fuvFucik 2026-03-16 ray-trace vignetting map for the FUV detector, masked to the detector footprintmodelfucik2026vignetting/response_files/vignetting_fucik2026_fuv_masked.fits
vignetting_nuvFucik 2026-03-16 ray-trace vignetting map for the NUV detector, masked to the detector footprintmodelfucik2026vignetting/response_files/vignetting_fucik2026_nuv_masked.fits
dark_current_fuvDark current in units of electrons per second per pixel for the FUV detectorsmodelCurrent Estimates0.001
dark_current_nuvDark current in units of electrons per second per pixel for the NUV detectorsmodelCurrent Estimates0.001
dark_current_lssDark current in units of electrons per second per pixel for the LSS detectorsmodelCurrent Estimates0.001
read_noise_fuvRead noise in units of electrons rms per pixel for the FUV detectorsmodelCurrent Estimates2
read_noise_nuvRead noise in units of electrons rms per pixel for the NUV detectorsmodelCurrent Estimates2