Metadata-Version: 2.5
Name: sungrow-modbus
Version: 0.1.0a45
Summary: Talk to Sungrow inverters, batteries and wallboxes over Modbus.
Project-URL: Homepage, https://github.com/mkaiser/Sungrow-SHx-Inverter-Modbus-Home-Assistant
Author: Martin Kaiser
License-Expression: MIT
License-File: LICENSE
Keywords: inverter,modbus,solar,sungrow
Requires-Python: >=3.13
Requires-Dist: modbus-connection>=4.10.0
Provides-Extra: discovery
Requires-Dist: zeroconf>=0.39.0; extra == 'discovery'
Description-Content-Type: text/markdown

<p align="center">
  <picture>
    <source media="(prefers-color-scheme: dark)" srcset="custom_components/sungrow_modbus/brand/dark_logo.png">
    <img src="custom_components/sungrow_modbus/brand/logo.png" alt="A PV array, an inverter, a battery and a car" width="480">
  </picture>
</p>

# Sungrow Modbus — Home Assistant integration

[![Discord Chat](https://img.shields.io/discord/1127341524770898062.svg)](https://discord.gg/ZvYBejFkm2)

> ## ⚠️ Preview. Do not use this branch on a system you care about.
>
> This is the `proper-ha-integration` branch: a rewrite of this project as a
> real Home Assistant integration, released only as previews (`0.1.0aN`).
> Registers can move, entity IDs can change, and nothing here promises
> backwards compatibility yet.
>
> **If you are a normal user, you want [`main`](../../tree/main)** — the YAML
> package, evolved over five years, in use by thousands of people, and the only thing
> that is finished.

## Trying it

It needs Home Assistant 2026.11 or later. Install it through **Settings →
Marketplace → Add from link** from the preview channel,
`Sungrow-SHx-Inverter-Modbus-Home-Assistant-preview`: the Marketplace reads a
repository's default branch, and this one's is the YAML package.
[doc/installing_a_preview.md](doc/installing_a_preview.md) has the steps;
[doc/integration_options.md](doc/integration_options.md) lists every option
under *Configure*, and [doc/integration_help.md](doc/integration_help.md) the
actions, the known limitations and what to try when something fails.

**The preview sets up diagnostics only**: it identifies the inverter and runs
the diagnosis, and creates no sensors for the readings. Everything below is
built and tested, and switched on in a later release.

## What this is

A Home Assistant integration on the Modbus architecture Home Assistant
introduced in 2026.9 (it needs 2026.11 or later), meant to **replace** the
YAML package. The hard requirement is that existing users keep their recorder history, long-term statistics and
dashboards when they switch ([doc/integration_migration.md](doc/integration_migration.md)).

**What it does:**

- All 135 read entities of the YAML package, held to it by tests, with the
  unit and state class of every entry they replace; created **only where the
  hardware has them**.
- **Writes**, each read back at once: the state-of-charge limits, charge and
  discharge maxima, the export power limit, three mode flags, three
  selects, and the forced-charging schedule (two windows as times, with a
  target SoC each). Start and stop are **actions**, with who may call them yours to
  choose (administrators by default).
- **The SBR battery** and **the wallbox** (AC011E-01 / AC22E-01, read-only)
  as devices of their own, behind a WiNet-S or, for the wallbox, at its own
  address over TLS.
- **One shared connection per inverter**, so no external Modbus proxy.
- **Discovered by Home Assistant** behind a WiNet-S, and a wallbox at its
  own address; otherwise set up by **searching the network**. Model, unit id
  and a cluster slave's role come from what the devices answer.
- **Configurable poll intervals**, per group, from 5 seconds to never.
- **A generator the Sungrow cannot see**: a non-Sungrow inverter behind the
  same meter, added back into the house load.
- **English and German**: names, dialogs and messages follow Home
  Assistant's language; entity ids stay English on every system, so one id
  means the same entity everywhere.
- **Diagnostics** to attach to a bug report, serial and host removed.
- **The diagnosis**, which reads what your installation answers, and the
  **capability test**, which writes each control, checks the inverter acted on
  it and puts everything back
  ([device-diagnosis/README.md](device-diagnosis/README.md)).

An **iHomeManager** found by the network search gets an entry of its own,
read only: the site's flows, its grid meter and its settings as set.

**Not yet:** the Sungrow Logger (never measured; see
[devices-wanted.md](device-diagnosis/devices-wanted.md)), SBH batteries, the
SBR's per-module entities, and writing to the wallbox.

[doc/energy_dashboard.md](doc/energy_dashboard.md) says which sensors to pick
for Home Assistant's Energy dashboard,
[doc/architecture.md](doc/architecture.md) is how it is built and why,
[Todo.md](Todo.md) what is open, and
[doc/compatibility.md](doc/compatibility.md) which setups have been diagnosed.

## Developing

Nothing here needs an inverter — there is a simulator.

```bash
scripts/dev/setup.sh       # devcontainer does this for you
scripts/dev/simulate.sh &  # a fake SH10RT on :5020
scripts/dev/develop.sh     # Home Assistant on :8123
```

Or `make setup`, `make sim-bg`, `make dev`. `make` on its own lists every
shortcut, and `make check` runs everything CI gates on.

Then *Settings → Devices & Services → Add integration → Sungrow Modbus*, and
point it at `127.0.0.1:5020`, unit id `1`.

[doc/development.yaml](doc/development.yaml) is the copy-paste runbook:
commands, the dev login, talking to real hardware, and getting the web UI onto
your LAN. [doc/development.md](doc/development.md) explains why things are the
way they are.

## The YAML package

It lives in [legacy/](legacy/) on this branch, and at the repository root on
`main`, which is where users should get it.

- [Installation / Configuration](legacy/doc/installation.md)
- [Migration from versions before 2026](legacy/doc/migration_guide.md)
- [Usage](legacy/doc/usage.md) · [FAQ](legacy/doc/faq.md) ·
  [Help / Troubleshooting](legacy/doc/help.md)
- [Changelog](legacy/doc/changelog.md)

## Register documentation

The mapping follows Sungrow's *Communication Protocol of Residential and Small
Industrial Hybrid Inverter*, **V1.1.16**, available from Sungrow support. If you
have a newer version, say so in the [discussions](../../discussions).

## Help and contributions

- [GitHub discussions](../../discussions) for questions, or
  [Discord](https://discord.gg/ZvYBejFkm2).
- [GitHub issues](../../issues) for bugs; attach a **diagnostics download**,
  which carries no serial and no address.
- **A diagnosis of your installation** is the most useful contribution, one that
  says everything works included: send it to
  [the diagnosis issue](https://github.com/mkaiser/Sungrow-SHx-Inverter-Modbus-Home-Assistant/issues/786).

## Related work

- **[HA Modbus Manager](https://github.com/TCzerny/ha-modbus-manager)**
- **[Sungrow Wallbox](https://github.com/Louisbertelsmann/Sungrow-Wallbox-Modbus-HomeAssistant)**
- **[Sungrow Logger 1000a](https://github.com/RafAustralia/Sungrow-Logger1000a-Modbus)**
- **[Chint DTSU666 Modbus](https://github.com/RafAustralia/Chint-DTSU666-20-modbus/)**
- **[EVCC](https://github.com/Hoellenwesen/home-assistant-configurations)**
- Sungrow document collections
  [by bohdan-s](https://github.com/bohdan-s/Sungrow-Inverter) and
  [by Gnarfoz](https://github.com/Gnarfoz/Sungrow-Inverter)

## Reuse and attribution

MIT: use this, change it, ship it commercially. Beyond the licence, one
request — **name where it came from** when code, a register map, a wiki page
or a measurement from here reaches your project or your answer to somebody's
question. The addresses were measured on real installations, and attribution
is the thread back to the firmware each finding holds on.
[doc/attribution.md](doc/attribution.md) says it in full, agents included.

## Acknowledgements

Five years of this project is the work of many people — everyone who filed a
register correction, tested a firmware, or answered a question in the
discussions. The YAML package's history is theirs.

The wallbox registers are nobody's official document, and two projects worked
theirs out by measurement:

- **[Louisbertelsmann/Sungrow-Wallbox-Modbus-HomeAssistant](https://github.com/Louisbertelsmann/Sungrow-Wallbox-Modbus-HomeAssistant)**,
  used here with its author's permission. Its charging-status enum is the one
  thing a single session cannot yield: watching a car finish charging shows
  the status settle on `6`, and only that table says `6` is *Completed*
  rather than idle.
- **[KevinD987/sungrow-ac011e](https://github.com/KevinD987/sungrow-ac011e)**
  (MIT), which publishes its register map with confidence marks and says
  plainly that nothing in it is manufacturer-confirmed. Its VERIFIED entry
  for the control-pilot voltage turned a hypothesis here into a second,
  independent measurement — on a different model.

[`doc/wallbox_registers.md`](doc/wallbox_registers.md) compares all three,
register by register, and says which of them holds each line.