Metadata-Version: 2.5
Name: simtest-funnel-mcp
Version: 1.0.0-beta.14
Summary: Local MCP server for funnel (tolerance-tube) comparison of signals in CSV files
Project-URL: Repository, https://github.com/Symoptia/simtest-funnel
Author: Symoptia contributors
License: MIT
Requires-Python: >=3.12
Requires-Dist: matplotlib>=3.8
Requires-Dist: mcp<3,>=2.3
Requires-Dist: numpy>=1.26
Requires-Dist: pandas>=2
Requires-Dist: simtest-funnel==1.0.0-beta.14
Description-Content-Type: text/markdown

# simtest-funnel-mcp

A local [MCP](https://modelcontextprotocol.io) server that lets AI agents
(Claude Code, Claude Desktop, any MCP client) compare signals stored in
local CSV files with the funnel (tolerance-tube) algorithm of
[simtest-funnel](https://github.com/Symoptia/simtest-funnel), a port of
[LBNL Funnel](https://github.com/lbl-srg/funnel).

The server reads the files itself, so raw samples never enter the model's
context. It is stateless: every call names the files it reads, and no
network connection is opened. `describe_signals` and `compare_signals` are
read-only; `plot_signals` writes exactly the plot file it is given (and
nothing at all without `output_path`), and only inside a workspace root
declared by the client or an output directory configured at start-up (see
[Where plot files may be written](#where-plot-files-may-be-written)).
Transport: stdio.

> **Platform note:** `simtest-funnel` is currently published to PyPI only
> as a Linux x86-64 / CPython 3.12 wheel, so `uvx simtest-funnel-mcp`
> works only there until cross-platform wheels are published. From a
> checkout of this repository it works wherever the Rust extension builds.

## Tools

### `describe_signals(path, columns=None, max_columns=100)`

Time column (and how it was chosen), row count, time start/end/span,
sampling (uniform or not; min/median/max step), per-column min/max/range
and data problems (non-numeric or empty cells, time not non-decreasing).
Use it to choose columns and tolerances. At most `max_columns` columns and
as many problems are listed; `columns_total`, `columns_selected`,
`columns_omitted` and `problems_omitted` state the rest. `columns` filters
by exact name or glob pattern (`*`, `?`, `[...]`), e.g.
`["*.port.signal"]`.

### `compare_signals(reference_path, test_path, ...)`

| Argument | Default | Meaning |
| --- | --- | --- |
| `columns` | all common columns | Signal columns to compare: exact names or glob patterns (`*`, `?`, `[...]`, matched against the columns of both files) |
| `tolerances` | one set, library default | List of sets: optional unique `label` plus any of the six coefficients |
| `column_tolerances` | none | `{column: coefficients}` overrides, applied per axis |
| `x_range` | unbounded | `{"lo": .., "hi": ..}` time window; finite bounds, omit one for unbounded |
| `max_intervals` | 5 | Violation intervals listed per failing row (largest deviation first) |
| `max_rows` | 100 | Rows returned (errors, then failures, then passes); totals always cover all rows |
| `include_snippet` | false | Add a pytest file reproducing the returned rows (for CI), in the structured field `snippet` |

The result has one row per (column, tolerance set) with verdict
(`pass` / `fail` / `error`), the library status code, points outside the
tube, fractions of points and span outside, the worst deviation and, for
failures only, the violation intervals. Missing columns, bad data and
other per-column problems are reported in their rows instead of failing
the call. Both structured content and a short text rendering are returned.
Time values are never rounded in the structured content; the text prints
them with enough digits to tell adjacent samples apart.

A column passes when every test point inside the compared time range
(`x_range` intersected with the reference time span) lies inside the tube
and, within `x_range`, both files cover the same time span. If one file
covers more time than the other within `x_range`, the row has verdict
`error` with status `MISSING_REFERENCE` (test extends beyond the
reference) or `MISSING_TEST` (the reverse), still reports
`points_compared` / `points_outside`, and its `problem` text names both
time spans and the exact `x_range` that compares the overlap.

### `plot_signals(reference_path, test_path, column, ...)`

Draws ONE comparison - one signal column, one tolerance set - and returns a
PNG preview (800 x 450 px) inline as MCP image content, so the model can
look at it. SVG is never returned inline (it would reach the model as text).

| Argument | Default | Meaning |
| --- | --- | --- |
| `column` | required | The one signal column to plot (exact name, no glob patterns) |
| `tolerance` | library default | One tolerance set: optional `label` plus any of the six coefficients (one entry of `compare_signals` `tolerances`) |
| `x_range` | unbounded | As in `compare_signals`; also the time window shown (zoom) |
| `output_path` | none | Write the plot here: `.svg` (document) or `.png` (1600 x 900 px), inside a workspace root or a configured output directory. Omit for the preview only |
| `overwrite` | false | Replace `output_path` if it exists (refused otherwise) |
| `max_intervals` | 5 | Violation intervals listed in the result row (all are drawn) |

The plot shows the reference (dark grey, dashed), the test (blue, solid),
the tolerance tube (grey band between thin lower and upper bound lines) and
every region where the test leaves the tube (red shading, with `x` markers
on the violating test points). The title states the column, the verdict,
the points outside and the non-zero resolved tolerances; the axes are
labelled with the time column and the signal column; a legend sits below the
axes. The background is white, so plots stay readable on light and dark
pages (on a dark page they appear as a light card).

The comparison runs on the full data with exactly the semantics of
`compare_signals`; the result carries the same summary row (plus the file
written, the preview size and how many points were drawn), never sample
values. For drawing, reference, test and both tube bounds are reduced to
the min/max of 1000 time buckets (the test keeping the worst point of every
violation interval), so the SVG stays fully vector and small (a few hundred
kB at most for 200 000 samples). Where needed, the exact bound value at a
drawn test point is added to the drawn bound, so a plot never contradicts
the verdict: every drawn test point lies inside or outside the drawn tube
exactly as the comparison judged it (violating points at least as far
outside as their deviation), every violation interval is shaded (at least
~3 px wide, even for a single sample) and contains a marked test point, and
in a passing plot no drawn test point lies outside the drawn tube. A column
that cannot be compared (missing, bad data, differing time spans,
non-monotonic time) is an error and nothing is written.

Output files: the file must lie inside a workspace root or a configured
output directory (below); a relative `output_path` is taken relative to the
first workspace root, else the first output directory; the directory must
already exist (none is created); a symbolic link must point to a file with
the same extension; an existing file is refused unless `overwrite=true`.
These checks run before any CSV file is read. The file is written only after rendering succeeded, so a
failed call writes nothing. Output is deterministic: the same input gives
byte-identical SVG and PNG files (with the same matplotlib version), so
plots can be kept in a repository and diffed. SVG text is embedded as
paths (bundled DejaVu Sans), so files look the same everywhere.

Plots are rendered with [matplotlib](https://matplotlib.org) (headless,
imported only on the first `plot_signals` call, so server start-up is not
slowed). It adds about 24 MB of wheels (~77 MB installed). matplotlib
keeps a font cache in its cache directory (`~/.cache/matplotlib`, or
`$MPLCONFIGDIR`), created on first use in an environment; that is the only
other file touched.

### Pytest snippet

With `include_snippet=true` the result carries a self-contained pytest
module (structured field `snippet`, sent once; the text rendering only
points to it) that asserts the observed status of every returned row; rows
omitted by `max_rows` are listed as a comment, and the snippet is capped
at 64 kB. It embeds the server's CSV reader verbatim. Data paths under the
first workspace root (else the server's working directory) are written
relative to it and resolved at run time against
`$SIMTEST_FUNNEL_DATA_ROOT`, defaulting to the current directory, so run
pytest from the same place in a CI checkout. Files outside that base keep
their absolute path, with a comment that they will not resolve elsewhere.

## CSV dialect

Comma-separated, one header row (UTF-8, optional BOM). Lines whose first
non-blank character is `#` and blank lines are ignored; a `#` anywhere
else is data (e.g. a column `a#1`). A data row with more fields than the
header is an error naming the row and line; a trailing delimiter on every
line, header included, is accepted (the empty last column is dropped).
Short rows count as empty cells. The time column is the first column named
`time` (case-insensitive), otherwise the first column; the choice is
echoed back. Other columns whose name differs from `time` only by case are
ordinary signal columns.

## Tolerances

Six coefficients, x = time axis, y = signal value. At each reference sample
the tube half-widths are

```text
half_x = max(atolx, rtolx * time_span_ref, ltolx * |t|)
half_y = max(atoly, rtoly * value_range_ref, ltoly * |y_ref|)
```

- `atol*`: absolute (time units / signal units)
- `rtol*`: fraction of the reference time span / value range
- `ltol*`: fraction of the local `|t|` / `|y_ref|`

If a half-width comes out effectively zero (`< 1e-10`), e.g. `rtoly` alone
on a constant reference (value range 0), it falls back to
`rtol * max|reference value|` on that axis (when `rtol > 0`), and finally
to `1e-10`. For constant or near-constant signals give `atoly` explicitly.

Omitted coefficients are resolved by the library, per axis: an axis with no
coefficient given gets `rtol = 0.002`; an axis with any coefficient given
uses `0` for its others; an explicit `0` counts as given. The six resolved
values are always echoed back.

**Tolerance in x** widens the tube along time, so a test signal shifted or
delayed by up to `half_x` still passes; steep edges and small timing
offsets then do not cause false failures.

"1 % in y, 0.5 s in x" is `{"rtoly": 0.01, "atolx": 0.5}` (or `ltoly` for
1 % of the local value).

## Registering the server

### Claude Code

Once published to PyPI:

```bash
claude mcp add simtest-funnel -- uvx simtest-funnel-mcp
```

From a checkout of this repository (use `--scope user` to make it available
in every project):

```bash
claude mcp add simtest-funnel -- uv run --directory /path/to/simtest-funnel --quiet simtest-funnel-mcp
```

Inside this repository nothing needs to be registered: the checked-in
[`.mcp.json`](../../.mcp.json) starts the server with `uv run` from the
workspace (Claude Code asks for approval the first time).

### Claude Desktop

Add to `claude_desktop_config.json` (Settings → Developer → Edit Config):

```json
{
  "mcpServers": {
    "simtest-funnel": {
      "command": "uvx",
      "args": ["simtest-funnel-mcp"]
    }
  }
}
```

or, from a checkout:

```json
{
  "mcpServers": {
    "simtest-funnel": {
      "command": "uv",
      "args": ["run", "--directory", "/path/to/simtest-funnel", "--quiet", "simtest-funnel-mcp"]
    }
  }
}
```

Use absolute paths in tool calls. When the client declares workspace roots,
the server refuses paths outside them and resolves relative paths against
the first root. Only local `file://` roots (empty host or `localhost`)
are used; other roots are ignored with a note in the result.

### Where plot files may be written

`plot_signals` writes a file only

1. inside a workspace root declared by the client (Claude Code declares the
   project directory), or
2. inside an output directory configured when the server is started:
   `--output-dir DIR` (repeatable) and/or the environment variable
   `SIMTEST_FUNNEL_MCP_OUTPUT_DIR` (several directories separated by `:`,
   `;` on Windows).

When both exist, a path inside either is allowed. With neither (e.g. a
client that declares no roots and no configured directory), every
`output_path` is refused with an error saying how to enable writing;
`plot_signals` without `output_path` still returns the inline preview. The
server's working directory is never used as a fallback. Each configured
directory must already exist (use an absolute path; `~` is expanded); the
server refuses to start otherwise, with a message naming the entry.

Claude Code needs nothing for plots inside the project. To also allow a
directory outside it, add the option to the command:

```bash
claude mcp add simtest-funnel -- uvx simtest-funnel-mcp --output-dir /home/me/plots
```

or, in a project's `.mcp.json`:

```json
{
  "mcpServers": {
    "simtest-funnel": {
      "type": "stdio",
      "command": "uvx",
      "args": ["simtest-funnel-mcp", "--output-dir", "/home/me/plots"]
    }
  }
}
```

Clients that declare no workspace roots (Claude Desktop, at the time of
writing) need an output directory to save plots
(`claude_desktop_config.json`):

```json
{
  "mcpServers": {
    "simtest-funnel": {
      "command": "uvx",
      "args": ["simtest-funnel-mcp", "--output-dir", "/Users/me/Documents/plots"]
    }
  }
}
```

or with the environment variable:

```json
{
  "mcpServers": {
    "simtest-funnel": {
      "command": "uvx",
      "args": ["simtest-funnel-mcp"],
      "env": { "SIMTEST_FUNNEL_MCP_OUTPUT_DIR": "/Users/me/Documents/plots" }
    }
  }
}
```

From a checkout, append the option after the command in the same way:
`"args": ["run", "--directory", "/path/to/simtest-funnel", "--quiet",
"simtest-funnel-mcp", "--output-dir", "/Users/me/Documents/plots"]`.

## Development

```bash
make build          # builds the native simtest-funnel module
make test-python    # includes python/simtest-funnel-mcp/tests (incl. stdio end-to-end)
make lint-python    # mypy --strict
uv run simtest-funnel-mcp   # start the server on stdio (--help for options)
```
