Name: bridge-mcp-server
Version: 0.4.0
Summary: Cross-platform intelligence bridge — correlate Ignition SCADA tags with Studio 5000 PLC logic
Project-URL: Homepage, https://github.com/Nodeblue-AI/bridge-mcp-server
Project-URL: Repository, https://github.com/Nodeblue-AI/bridge-mcp-server
Project-URL: Issues, https://github.com/Nodeblue-AI/bridge-mcp-server/issues
Project-URL: Changelog, https://github.com/Nodeblue-AI/bridge-mcp-server/blob/main/CHANGELOG.md
Author-email: Nodeblue <contact@nodeblue.ai>
License-Expression: MIT
License-File: LICENSE
Keywords: cross-reference,ignition,industrial-automation,mcp,plc,rockwell,scada,studio5000
Classifier: Development Status :: 3 - Alpha
Classifier: Intended Audience :: Developers
Classifier: License :: OSI Approved :: MIT License
Classifier: Programming Language :: Python :: 3
Classifier: Topic :: Scientific/Engineering
Requires-Python: >=3.10
Requires-Dist: fastmcp==3.2.3
Requires-Dist: ignition-mcp-server
Requires-Dist: studio5000-mcp-server
Description-Content-Type: text/markdown

# bridge-mcp-server

> Cross-platform intelligence bridge — correlate Ignition SCADA tags with Studio 5000 PLC logic end-to-end.

[![License: MIT](https://img.shields.io/badge/license-MIT-blue.svg)](LICENSE)
[![Python 3.10+](https://img.shields.io/badge/python-3.10+-blue.svg)](https://www.python.org/downloads/)
[![MCP](https://img.shields.io/badge/protocol-MCP-green.svg)](https://modelcontextprotocol.io/)

> [!NOTE]
> **This connector is early community tooling from [Nodeblue](https://www.nodeblue.ai).** The complete system is [**Nexus**](https://www.nodeblue.ai/nexus), our industrial intelligence platform — these repos are just its connector layers.
>
> Nexus reads and reasons over your entire operation: PLC logic, SCADA systems, live controller data, documentation, fault history, and MES/ERP records. It works across vendors — Rockwell, Siemens, Ignition, the CODESYS family, and 500+ more brands through PLCopen. It diagnoses faults on the running line, holds a persistent memory of the operation, and answers in plain English, cited to the source.

### The Nodeblue open-source connectors

| Connector | What it does |
|---|---|
| [studio5000-mcp-server](https://github.com/Nodeblue-AI/studio5000-mcp-server) | Rockwell/Allen-Bradley Studio 5000 — parse L5X exports: tags, UDTs, routines, AOIs, cross-references |
| [ignition-mcp-server](https://github.com/Nodeblue-AI/ignition-mcp-server) | Ignition SCADA — views, scripts, tags, UDTs, alarms, live gateway read/write |
| **bridge-mcp-server** (this repo) | Correlates Ignition SCADA tags with Studio 5000 PLC logic end-to-end |

---

## What This Does

`bridge-mcp-server` connects [ignition-mcp-server](https://github.com/Nodeblue-AI/ignition-mcp-server) and [studio5000-mcp-server](https://github.com/Nodeblue-AI/studio5000-mcp-server) via the [Model Context Protocol](https://modelcontextprotocol.io/). It gives AI agents the ability to:

- **Correlate** — build a full tag-by-tag map between an Ignition SCADA project and a Studio 5000 L5X PLC export
- **Trace** — follow a single tag end-to-end from Ignition config → OPC item path → L5X tag → every rung of PLC logic that references it
- **Find gaps** — identify commissioning mismatches: Ignition OPC tags with no PLC counterpart, and L5X tags with no Ignition reference

It maps Ignition OPC tag paths to L5X tag names using convention-based normalization (with optional explicit mapping file override), then leverages the Studio 5000 cross-reference engine to find every line of PLC logic that references the matched tag.

## Why This Exists

Ignition and Studio 5000 are the two most common platforms in North American industrial automation, and they almost always exist together — yet there's no tooling that connects them. Commissioning engineers manually cross-reference tag databases in spreadsheets. This server automates that.

Built and maintained by [Nodeblue](https://www.nodeblue.ai). These connectors are early community tooling from our work on [Nexus](https://www.nodeblue.ai/nexus), where this capability ships production-grade — alongside cross-vendor correlation, live fault diagnosis, and a persistent memory of the operation.

---

## Installation

Install from source:

```bash
git clone https://github.com/Nodeblue-AI/bridge-mcp-server.git
cd bridge-mcp-server
pip install -e .
```

This also installs `ignition-mcp-server` and `studio5000-mcp-server` as dependencies.

Requires Python 3.10+.

> **Note:** `pip install bridge-mcp-server` from PyPI is coming soon. For now, install from source as shown above.

---

## Quick Start

### stdio (local — kiro-cli, Claude Desktop, Claude Code)

```bash
bridge-mcp-server
```

### SSE (remote — server on one machine, agent on another)

```bash
bridge-mcp-server --transport sse --port 8082
```

---

## Configuration

### kiro-cli

Add to your `~/.kiro/settings.json`:

```json
{
  "mcpServers": {
    "bridge": {
      "command": "bridge-mcp-server",
      "args": []
    }
  }
}
```

### Claude Desktop

Add to your Claude Desktop MCP config:

```json
{
  "mcpServers": {
    "bridge": {
      "command": "bridge-mcp-server",
      "args": []
    }
  }
}
```

### SSE (remote)

Start the server on your engineering workstation:

```bash
bridge-mcp-server --transport sse --host 0.0.0.0 --port 8082
```

Connect from any MCP client using the SSE URL: `http://<host>:8082/sse`

---

## Available Tools

### `ping`
Health check. Returns `"pong"`.

### `correlate_projects(ignition_path, l5x_path, mapping_file?)`
Build a full correlation map between an Ignition project and an L5X PLC project.

```
correlate_projects("/path/to/ignition-project", "/path/to/plc.l5x")
```

Returns:
```json
{
  "matched": [
    {
      "ignitionPath": "Conveyors/Line1/Running",
      "opcItemPath": "ns=1;s=[PLC]Motor_1.Running",
      "l5xTag": "Motor_1",
      "l5xMember": "Motor_1.Running",
      "l5xDataType": "Motor_UDT",
      "l5xScope": "controller"
    }
  ],
  "ignitionOnly": [],
  "l5xOnly": [
    {"name": "EmergencyStop", "dataType": "BOOL", "scope": "controller"}
  ],
  "stats": {"matched": 3, "ignitionOnly": 0, "l5xOnly": 5, "totalIgnitionOpc": 3, "totalL5x": 8}
}
```

### `trace_tag(ignition_path, l5x_path, tag_name, mapping_file?)`
Deep end-to-end trace of a single tag from SCADA to PLC logic.

```
trace_tag("/path/to/ignition-project", "/path/to/plc.l5x", "Running")
```

Returns the complete signal chain: Ignition tag config → OPC item path → L5X tag details → every rung/line of PLC logic that references it.

### `find_unmapped_tags(ignition_path, l5x_path, mapping_file?)`
Identify commissioning gaps — tags that exist on one side but not the other.

```
find_unmapped_tags("/path/to/ignition-project", "/path/to/plc.l5x")
```

---

## OPC Path Mapping

The bridge uses convention-based mapping by default:

| Ignition OPC Item Path | L5X Tag Name |
|---|---|
| `ns=1;s=[PLC]Motor_1.Running` | `Motor_1.Running` |
| `[PLC]Motor_1.Running` | `Motor_1.Running` |
| `[PLC]Program:MainProgram.StartPB` | `Program:MainProgram.StartPB` |
| `Motor_1.Running` | `Motor_1.Running` (passthrough) |

For complex setups (aliased tags, scaled values), provide a JSON mapping file:

```json
{
  "ns=1;s=[PLC]Custom_Alias": "Motor_1.Running",
  "ns=1;s=[PLC]Scaled_Speed": "LineSpeed"
}
```

Pass it via `mapping_file` parameter on any tool.

---

## Use Cases

### Pre-commissioning validation
> "Show me every Ignition OPC tag and its matching PLC tag — I need to verify the full correlation before we go live."

```
Agent calls: correlate_projects("/projects/MyPlant", "/plc/MainPLC.l5x")
```

### Alarm root-cause analysis
> "The Conveyors/Line1/Running tag is triggering an alarm in Ignition. What PLC logic drives it?"

```
Agent calls: trace_tag("/projects/MyPlant", "/plc/MainPLC.l5x", "Running")

Agent: The Ignition tag Conveyors/Line1/Running maps to PLC tag Motor_1.Running
via OPC path ns=1;s=[SampleController]Motor_1.Running.

Motor_1 is a Motor_UDT instance. Motor_1.Running is referenced in:
- MainProgram/MainRoutine rung 1: Motor_Control AOI call
- MainProgram/MainRoutine rung 2: Fault detection branch
- MainProgram/FaultHandler line 1: IF Motor_1.Faulted THEN...

The Motor_Control AOI sets Running from MotorFeedback (rung 4).
```

### Commissioning gap analysis
> "Which PLC tags exist in the L5X but aren't wired up in Ignition yet? We need to close gaps before FAT."

```
Agent calls: find_unmapped_tags("/projects/MyPlant", "/plc/MainPLC.l5x")
```

---

## Roadmap

### v0.4 — Cross-Platform Correlation ✅
- [x] `correlate_projects` — full tag-by-tag map between Ignition and L5X
- [x] `trace_tag` — end-to-end signal chain from SCADA to PLC logic
- [x] `find_unmapped_tags` — commissioning gap detection
- [x] Convention-based OPC path → L5X tag name normalization
- [x] Optional JSON mapping file for explicit overrides
- [x] Correlation index caching per project pair
- [x] stdio and SSE transport support

### Maintenance
- [ ] Mapping file auto-generation from correlation results (contributions welcome)
- [ ] PyPI publication (`pip install bridge-mcp-server`)
- [ ] Bug fixes and OPC path-convention edge cases from real projects — [issues welcome](https://github.com/Nodeblue-AI/bridge-mcp-server/issues)

This connector is feature-complete for its scope: **one Ignition project against one L5X export**. Development beyond that scope happens in Nexus.

---

## This Connector vs. Nexus

The connector is the access layer. [Nexus](https://www.nodeblue.ai/nexus) is the intelligence that sits on top of it — and of every other connector — as one system.

| Capability | This connector | Nexus |
|---|:---:|:---:|
| Correlate one Ignition project with one L5X export | ✅ | ✅ |
| Trace a single tag from SCADA to PLC logic | ✅ | ✅ |
| Commissioning gap detection | ✅ | ✅ |
| Multi-PLC / whole-plant correlation | — | ✅ |
| Alarm pipeline → PLC trigger-logic tracing | — | ✅ |
| Cross-vendor: Siemens, CODESYS family (500+ brands), OPC UA | — | ✅ |
| Live fault diagnosis on the running line (root-cause, cited) | — | ✅ |
| Knowledge layer: your manuals, SFS/DOO docs, fault history — searchable, linked to logic | — | ✅ |
| Persistent memory of the operation across sessions | — | ✅ |
| Fleet scale: auto-discovery, whole-plant inventory, monitoring, alarming | — | ✅ |
| Local LLM / air-gapped deployment | — | ✅ |

If you're evaluating this connector for more than one PLC, [talk to us about Nexus](https://www.nodeblue.ai/nexus).

---

## Development

```bash
git clone https://github.com/Nodeblue-AI/bridge-mcp-server.git
cd bridge-mcp-server
pip install -e .
pip install pytest
pytest tests/ -v
```

### Project Structure

```
src/bridge_mcp_server/
├── __init__.py       # v0.4.0
├── __main__.py       # CLI entry point (stdio/SSE)
├── server.py         # FastMCP with 4 tools (ping + 3 correlation tools)
└── correlator.py     # OPC path normalizer + correlation engine

tests/
└── test_correlator.py
```

---

## License

MIT — see [LICENSE](LICENSE).

---