Survey Reference Gradient Correction — SRGC

Removes the part of your background that the real sky does not explain. SRGC fetches an image of your exact field from a published survey — or uses a frame from your own second scope — models both backgrounds on the same sample points, and subtracts only the residual. Real nebulosity survives because it is present in the reference too. Requires a plate solution; the survey path also needs a network connection. Non-destructive: nothing changes until Apply.

1. Why this exists

ADBE models your background and removes it. The problem it cannot solve is attribution. Your background is

B_t(x,y) = s\,S(x,y) + G(x,y) + c

where \(S\) is real diffuse sky structure — nebulosity, IFN, galactic cirrus — and \(G\) is your gradient: light pollution, airglow, a vignetting residual, moonlight. A self-contained model sees one surface and has no way to tell those apart, so it removes some of each. That is why large faint structure quietly flattens out, and it is the reason PixInsight funded an entire survey (MARS) to attack the same problem.

SRGC breaks the degeneracy with outside information. It fetches a reference image of the same patch of sky, models its background the same way, and fits

B_t \approx a + b\,B_r

robustly across the frame. Whatever is left over,

G = B_t - (a + b\,B_r)

is the part of your background the real sky does not account for. That is your gradient, and that is what gets subtracted. Nebulosity is in the reference too, so it is absorbed by the \(b\,B_r\) term and comes through untouched.

When to use which. ADBE is offline, unconditional, and right for ordinary vignetting and smooth light pollution on a sparse field. Reach for SRGC when the field has real large-scale structure you are afraid of losing — IFN, cirrus, a big nebula filling the frame, or anything where ADBE's result looked suspiciously flat.

2. Using the tool

2.1 Before you start

Linear data is the home ground, but a stretched image is not a write-off. SRGC models your gradient as something added to the sky and subtracts it, which is exactly true while the data is linear. It stays a good approximation after an ordinary stretch, because a stretch does almost nothing curved down where the background lives: the background occupies a sliver at the bottom of the histogram, and over a sliver any smooth curve is its own tangent — which is precisely what an additive model is. See §3.7 for the measurements. What does break it is anything spatially varying — masked stretching, local contrast, HDR compression — because that is no longer one transfer function, so there is no single tangent to stand in for it.

The image must be plate-solved: the reference is fetched and aligned by sky coordinates, so without a WCS there is nothing to look up. If the image has no solution SRGC offers to run the plate solver for you. With no pointing in the header that falls back to a blind solve, which searches the quad index and can take a few minutes — so it always asks first and never starts one on its own.

2.2 Choosing a reference

Reference source selects between a published survey and your own image.

Survey

Pick the survey whose content matches your data, not simply the deepest one. A narrowband frame should be matched against a narrowband reference: fitting an Hα image against a broadband continuum plane regresses your gradient against structure that is not in your channel.

SurveyUse it forCoverage
NSNS visual continuum — monoGeneral broadband work in the north. Linear intensity in Rayleighs, star-subtracted. The default.dec ≥ −16°
NSNS SHO (Hα / [OIII] / [SII])SHO-mapped narrowband — each channel is matched to the line it was imaged in.dec ≥ −16°
NSNS HOO / SOOOne-shot colour behind a dual narrowband filter. The Bayer matrix already sorted the passbands, so your frame is an HOO composite and the reference is built to be one too.dec ≥ −16°
NSNS Hα / [OIII] / [SII] — monoSingle-line mono data.dec ≥ −16°
NSNS OHS ([OIII] / Hα / [SII])Data mapped in the OHS palette, which the SHO entry cannot match — it pairs the channels the other way round. One download instead of three, at the cost of an 8-bit tonal curve.dec ≥ −16°
NSNS HBR (Hα / blue cont / red cont)Colour data where Hα dominates one channel. The only NSNS tree that separates the blue and red continuum — vc combines them.dec ≥ −16°
NSNS RGB continuum — colourBroadband colour in the north with a real three-colour reference — neither a photographic plate nor 36% of sky. 8-bit tonal curve and partial star subtraction.dec ≥ −16°
SHASSA Hα — monoNarrowband in the south. The Southern Hα Sky Survey Atlas, continuum subtracted, linear FITS at 0.8′ — a real survey, seven times finer than the Finkbeiner composite.dec ≤ +15°
VTSS Hα — monoNorthern Hα at 1.6′, linear FITS in Rayleighs. Ten times coarser than NSNS, so reach for it when the non-commercial clause is a problem, or as a second opinion.northern
DSS2 red + NSNS continuum — colourColour data in the north. Two genuinely different planes, so each of your channels gets its own reference.dec ≥ −16°
DSS2 colour from 8-bit tiles — colourColour data anywhere, including the south. Real red/green/blue bands out of one download.all sky
Finkbeiner Hα composite — monoNarrowband in the south. WHAM + VTSS + SHASSA combined into one full-sky Hα map (Finkbeiner 2003), linear FITS in Rayleighs. Every other narrowband option stops at dec −16°. Native resolution is ~6′, so it constrains a gradient across a wide field and has little to say across half a degree — check the survey/yours split.all sky
DSS2 red — monoThe dependable fallback. Photographic plates, all sky, always there.all sky
HI4PI neutral hydrogen — monoNot an optical survey. 21 cm HI column density as a cirrus template: the HI traces the galactic structure a gradient fit must not mistake for a gradient, and light pollution is not in it, so what the fit leaves behind is the gradient. The HI-to-optical ratio varies across the sky — read it as a prior, not a measurement.all sky
Southern narrowband, in order. SHASSA first, below dec +15° and inside its footprint. The Finkbeiner composite above that, or wherever SHASSA has nothing — it is all-sky but coarse. Every NSNS entry stops at dec −16°.

The note under the dropdown describes the selected survey and leads with a ⚠ warning when it cannot currently fetch. Availability is not decoration: survey hosting moves, and mirrors go down. SRGC re-checks the unavailable entries in the background each time you open the dialog, and tells you if one has come back.

Every NSNS entry is CC‑BY‑NC‑SA. The NSNS layers — the linear ones and the colour composites alike — are published by Stefan Ziegenbalg under a licence with a non-commercial clause. The DSS2, SDSS, SHASSA, VTSS, Finkbeiner and HI4PI options carry no such restriction. For commercial output on narrowband data use SHASSA in the south, VTSS or the Finkbeiner composite in the north.

Your own image — the dual-scope case

If you run two scopes on one mount, the wide one is very likely a better reference than any survey: it saw the same sky, on the same night, through the same light pollution and the same airglow. A survey tells you where real nebulosity is. A simultaneous wide frame tells you that and what the sky was doing at the time.

Choose it from the list of open images, or load a file directly. Two requirements:

The one real trap. Your reference must not carry the same gradient. If both frames tilt the same way, \(b\) absorbs the tilt and the residual is empty — SRGC will report that it removed almost nothing. That is not a wrong answer, it is an honest one, and the reference share figure (§3.9) tells you when it has happened.

2.3 The controls

ControlWhat it does
Work resolutionLong side of the grid the reference is fetched on and both backgrounds are modelled at. A gradient is low-frequency by definition, and NSNS resolves ~10″ anyway, so larger is slower without being better. 1024 is right.
Background degree (0–4)Polynomial order for both background models. Keep it low. A high-degree model on the target absorbs real structure before the reference ever gets a chance to explain it, which defeats the whole method. 1–2.
Sample pointsHow many background samples are placed. One set is generated and used for both models — see §3.3.
Patch size (px)Window whose statistic is taken at each sample point. Larger is more robust to stars, but blurs the line between sky and faint extended signal.
Exclude brightestPercentage of the survey's brightest pixels that are off-limits to sampling. Raise it on a field dominated by a big object; lower it on sparse fields.
Protect k (MAD)Signal protection on the reference, in MAD-sigma units — the same median + k·MAD threshold ADBE's multiscale stage uses. Lower protects more. Drop to 1.5–2 on a field with a large bright object.
RBF refinementRadial-basis refinement on both background models, after the polynomial.
Strength (0–150%)How much of the modelled gradient to subtract. 100% is the fit. Above it deliberately over-corrects — useful for telling a real gradient residual from something the reference never explained.

Remove dust motes / reflections (optional)

Everything above is additive — sky added on top of your signal. Dust motes, internal reflections and vignetting are multiplicative: they scale what was already there, and no additive fit can take them out. Ticking this runs ADBE’s multiscale stage afterwards, as a second pass, dividing out a band of wavelet scales. The core is ADBE’s verbatim; what SRGC adds is the protection — see the last row.

ControlWhat it does
Scales (1–12)The wavelet band the defect is estimated from. 6–8 is where dust motes and reflections live: coarse enough to miss stars and noise, fine enough to keep their edges. Lower catches smaller, sharper defects; higher drifts toward the smooth gradient the additive stage has already dealt with.
Include coarsest residualFolds everything coarser than that band into the correction as well. Leave it off unless a broad multiplicative falloff survives the additive stage — vignetting the flat missed, typically. Be more careful with it here than in ADBE: the smooth background has already been removed additively, and removed against a reference that says which large-scale structure is real sky. The coarsest residual is exactly where that structure lives, so folding it in can divide out nebulosity the survey just finished vouching for — on top of correcting the gradient twice. It also costs time: the full pyramid has to be built rather than stopping at the top of the band.
Refine strengthHow much of the multiplicative correction to apply. 1.00 applies it fully; ease it down if the correction flattens real large-scale structure.
Protect k (MAD)As above, but for this stage: what counts as signal that must not be divided out. Lower protects more.
Remove stars first (DarkStar)Estimates the defect band on a starless copy while the protection mask is still built on the star-inclusive image. That pairing is what makes the band clean; leave it on unless DarkStar is unavailable.
Protect real structure using the surveyThe one thing SRGC knows that ADBE cannot. ADBE builds its protection from the image itself, so a bright extended blob looks the same whether it is a nebula or an internal reflection; here the survey says which. Real structure is kept from the untouched source, and anything sharp sitting on sky the survey says is empty is treated as a defect. Hand-drawn exclusion zones protect unconditionally, whether or not this is ticked.

2.4 Running it, and reading the views

Fetch & Model does the work; Apply commits it. The six view tabs are where the tool earns your trust:

ViewWhat to look for
CorrectedThe result. Tick Before to flick back to the image as it was when the model was built — it stays a true "before" even after you Apply.
Gradient removedWhat is being subtracted. It should look like a gradient: smooth, large-scale, no nebula in it. If you can see your target in here, the model is eating signal — lower the degree or the protect k. Carries the same scale control as the two background views, and under linear it gains a reading the others do not have: the gradient is already median-subtracted, so mid-grey is literally zero. Grey means nothing was removed at that pixel, brighter means subtracted, darker means added back. Under min/max that reading is lost, because the darkest pixel becomes black whatever its value.
ReferenceThe fetched cutout. Confirm it is the right piece of sky and the right way up. If it reports MONO, every channel resolved to the same plane — a colour survey degraded because only one of its channels could be fetched.
Reference / Target backgroundThe two modelled surfaces. These and Gradient removed each carry the same scale control at the top of the tab — one setting shared by all three, since all three draw a surface rather than a picture:
  • Scale: min/max — the default. The surface’s own range is stretched to fill 0–1 and then tone-mapped, so a field varying by 0.1% fills the screen. This is the only way to see the shape of the gradient, and it makes a nearly-flat background look violent. Trust the number in the status bar, not the picture.
  • Scale: linear — \( 0.5 + (B - \mathrm{med}\,B) / 2 \), per channel, with no tone map. The median sits on mid-grey and the gradient keeps its true amplitude, so a 0.002 background is a barely-visible grey wash — which is what it is. The status bar reports what fraction of the tonal range it fills. Full black to full white here would mean the background spans 1.0, i.e. something has gone wrong. Per channel because an OSC background carries a different offset in each, and a single global median would push R and B off grey and read as a colour cast that is not in the gradient.

    On the Survey background tab this mode shows \( b\,B_r \) rather than \( B_r \) itself. The reference is in the survey’s own units — a DSS2 plate arrives as 1130–20528 counts — so a true-scale mapping of those numbers against a 0–1 frame is meaningless and rails every pixel (a 2409-count span was reported as filling 120480% of the tonal range). \( b\,B_r \) is the term the fit actually subtracts, and it is in your units by construction, so the two background tabs land on the same mapping and can be read against each other: what the survey contributes, beside what you started with. \( b \) keeps its sign, so an anti-correlated reference shows inverted — which is how it is being subtracted. The status bar still reports the raw span in survey counts as well.

Use min/max to judge the shape, linear to judge whether the shape is worth correcting at all.
Sample pointsGreen dots are the points used; red tint is vetoed by the survey. A point sitting on anything bright in this view is sampling structure. Your own gradient is deliberately invisible here — see §3.4.

Run diagnostics probes every route for the selected survey with a tiny cutout and reports what each one returned. Use it when a fetch fails: it separates a dead host from a rejected request from a genuine footprint miss, which all look identical from the main error message.

2.5 Pushing a view out as its own document

Current view → new document, in the button column beside Run diagnostics, hands whatever you are looking at to the main window as a new image document — the way ADBE can write its background out separately. It acts on the tab you are on, and the tooltip changes with the tab to say exactly what you will get. It changes nothing here: the correction is still only committed by Apply.

Each view is a different kind of thing, so each one is handed over in the form that is actually usable, and the status bar says which:

TabWhat you get
Target image_SRGC_Corrected — the corrected image at the current strength, full resolution, the same pixels Apply would commit — except that this document is new, so the original is left alone. With Before ticked you get _SRGC_Before instead, the uncorrected snapshot the model was built from, so you can keep both and blink them.
Survey reference_SRGC_Reference — the fetched cutout, at work resolution rather than yours, because that is the grid it was reprojected onto and upscaling it would invent detail it never had. If its values fall outside 0–1 — a DSS2 plate arrives as 1130–20528 counts — it is rescaled by its own range and the range is recorded in the metadata, so it behaves like every other document in SASpro. Nothing the correction used is lost: the fit absorbs any linear scale (§3.6).
Gradient removed_SRGC_Gradient — the surface being subtracted, full resolution, in your image’s units, with your median added back. The gradient is median-subtracted, so half of it sits below zero; shifted up to your sky level it is positive, autostretch shows it, and nothing that clips at zero can eat half of it. The amplitude is untouched — only a constant differs — so subtract this document and restore the median and you have redone the correction by hand.
Target background_SRGC_Background — your modelled background, full resolution, exactly as the model made it. The one surface that needs no adjusting: it is already in your units and at your own sky level. This is the direct equivalent of ADBE’s background document.
Survey background_SRGC_RefBackground — \( b\,B_r \), the term the fit subtracts, full resolution. Not the raw survey background, for the same reason the linear view does not show it: that is in survey counts and means nothing beside a 0–1 frame. Its median is moved to yours, so it blinks against _SRGC_Background — what the survey contributes, beside what you started with.
Sample points_SRGC_Points — the point map as drawn, at work resolution. This one is a picture, not data: the green dots and the red veto tint are painted into the display render, so what you get is that render promoted to float. Good as a record of what was sampled; not something to measure.

The four full-resolution pushes sit on your pixel grid, so they inherit your image’s header and its WCS and can be combined with it directly. The two work-grid pushes deliberately do not — a header whose NAXIS disagrees with the array it describes is a trap for whatever saves the file later. Every pushed document records which view it came from, the survey, the strength, the coverage and the fitted coefficients in its metadata.

The quickest sanity check in the tool. Push Gradient removed and Target background, then look at them beside each other at the same stretch. The background is the whole sky surface; the gradient is only the part the survey could not explain. If those two look alike, the reference contributed nothing and you are doing ADBE with extra steps — which §3.9 measures for you as the reference share.

3. Technical details

What follows is the method rather than the interface. None of it is needed to use the tool.

3.1 Scale

The reference is fetched and both backgrounds are modelled at reduced resolution, 1024 px on the long side by default. This is not a shortcut. A gradient is by definition a low-spatial-frequency field, and the degeneracy this tool exists to break lives only at large scales. Working small also keeps the fit well conditioned and the download small. The modelled gradient is upscaled back to full resolution before it is subtracted.

3.2 Getting the reference

Every survey here is published as a HiPS (IVOA Hierarchical Progressive Survey) — the sky tiled into HEALPix cells at a pyramid of resolutions. SRGC reads the static tile trees directly: it maps each output pixel to a HEALPix index, fetches the tiles that cover the field in parallel, and samples them onto your WCS. It does not depend on a reprojection service.

Each survey carries several mirror URLs, tried in order, leading with a non-CDS host wherever one exists. A failed route is treated by kind: an HTTP 404 retires that one path, because a mirror may carry one band and not another; a connection timeout retires the whole host, because every further route on it would time out too. A TCP pre-flight settles an unreachable host in a couple of seconds rather than waiting out the operating system's connect timeout.

A fetched reference is cached for the session, keyed on the survey, the work resolution and your image's pointing and scale. Changing degree, samples, patch size, exclusion, protect k or strength and re-running therefore costs no download at all — those are exactly the knobs worth re-running.

3.3 One set of sample points, for both models

This is the difference between a reference-based correction that works and one that quietly eats nebulosity.

Modelling the two backgrounds independently lets each chase structure in its own way — different noise, different resolution, different star content. Since the fit downstream is \(B_t \approx a + b\,B_r\), any structure one model follows and the other does not lands in the residual and is subtracted as "gradient". Sampling both at the same sky positions makes those errors common-mode, and common-mode error is precisely what the \(b\,B_r\) term exists to absorb.

3.4 The survey decides where background is

Sample points are chosen on

M = \max\left(\,\mathrm{norm}(B_r)\,,\ \mathrm{norm}(\mathrm{highpass}^{+}(I_t))\,\right)

The reference supplies the diffuse-structure veto, and your frame contributes only its high-pass: stars, trails, sharp artefacts.

Your own brightness deliberately gets no vote on whether a location is background. The target is the frame with the gradient in it — that is the entire premise — so treating a bright patch of light pollution as "not background" would starve the fit on the bright side of the gradient and bias the model toward the dim corner. It is also self-defeating: the gradient is the quantity being measured, so declining to sample where it is strong is declining to measure it. A high-pass is blind to a smooth gradient by construction, so a point sitting in the brightest corner of your light pollution is a perfectly good background sample, while a point on a star is not.

On top of that, two hard vetoes are applied to the reference: the brightest exclude% of covered sky, and a median + k·MAD signal mask, dilated and blurred. Both are smoothed at the patch scale first and have their interior holes filled — a dust lane inside a galaxy is dimmer than the sky outside it, so on a raw map it passes a brightness test and acts as a local minimum that the sampler walks straight into. Filling holes is what stops a point landing between M31's dust lanes. If structure dominates the frame the thresholds are relaxed until enough sky is samplable, and the relaxation is reported rather than hidden.

3.5 The fit

Per channel, sigma-clipped least squares for \(B_t \approx a + b\,B_r\), iterated with a MAD-based scale:

\sigma = 1.4826\,\mathrm{MAD}(r)\,,\qquad \mathrm{keep}: |r - \mathrm{med}(r)| < 2.5\,\sigma

Clipping matters more than usual here. Anything your frame has that the reference does not — a satellite trail, a reflection, a processing artefact, a galaxy the survey is too shallow to show — would otherwise tilt the fit, and a tilted fit becomes a gradient that gets subtracted. Clipping removes those before they can.

The fit runs over the whole covered frame, including the vetoed region. Restricting it to sample-constrained pixels looks more principled and measures worse: on a controlled test \(b\) fell from 0.122 to 0.081 against a known truth of 0.129, and recovery correlation dropped from 0.983 to 0.936. Two reasons. The vetoed region is not invented data — both backgrounds there are smooth predictions from the same points through the same kernel, so their extrapolation errors are correlated and cancel in a linear fit. And excluding it throws away the high-\(B_r\) end of the range, which is the leverage that determines \(b\) at all.

Colour data is fitted per channel. Light pollution is strongly colour-selective, so a red sky and a blue sky need to be explained by red and blue structure rather than by one grey average. Against a mono reference each channel still solves its own \((a, b)\) — the structure is assumed to have the same shape in every channel and a different amplitude, which is an approximation, but a far better one than no reference at all.

3.6 Units, and why nothing needs rescaling

A survey cutout and your frame are in completely unrelated units — a DSS2 plate arrives as roughly 1100–20000 counts against your 0–1 floats — which raises the obvious worry that the two sides of the fit are not comparable. They are, and the fit form is the reason. Because it solves \( B_t \approx a + b\,B_r \), any linear rescaling of either side is absorbed exactly:

The sigma clipping does not break this either, because its threshold is MAD-based and so scales with the data. Measured: a target or reference rescaled by \( 10^4 \) changes the recovered gradient by about \( 10^{-8} \), which is float32 round-off and not a difference. So matching the two images' scales before the fit, and undoing it afterwards, is provably a no-op — and it is worse than neutral if done carelessly: rescaling a small signal onto a large pedestal cost 0.18% of the gradient span to float32 cancellation in the same test.

What the fit cannot absorb is curvature — a reference that encodes brightness non-linearly, as a log-stretched 8-bit composite does. In practice this costs very little, for a structural reason: the fit runs on background models, not raw pixels, and a background spans a narrow range by construction. Any smooth monotone curve is close to its own tangent over a narrow range, and a tangent is exactly what \( a + b\,B_r \) fits. On a real DSS2 fetch the reference background spanned 2.2% of its own sky level, which puts the second-order term of a log at about 1.1% of the reference term — and that term explained 31% of the gradient, so roughly 0.35% of the correction. Swapping a linear reference for a log, asinh, gamma or 8-bit-quantised one changed recovery by 0.01 percentage points in a controlled test.

The tool therefore does not rescale anything. It reports instead: the Survey reference tab names the format it fetched, how that tree encodes brightness (linear, log, or high-passed) and whether it can resolve a gradient at all — see §3.8.

3.7 Does it still work on stretched data?

§3.6 is about a curved reference. This is the other half of the same question: a curved target. The answer is better than the additive model has any right to expect, and the reason is where the background sits.

A statistical stretch lifts the background enormously — measured local gain 30× at a 0.25 target median, 39× at 0.40 — but it lifts it almost uniformly. On a synthetic frame whose background occupied 0.0215–0.0259, the stretch departed from a straight line across that whole range by only 4.2% (6.9% at a 0.40 median) of what it did to the range. The knee is a feature of the curve somewhere else entirely; the background rides a nearly straight piece of it. That straight piece is a gain, and a gain is exactly what \( a + b\,B_r \) already solves for.

End to end, with the gradient recovered and scored against the truth in stretched space:

TargetRecovery errorvs linear
linear (baseline)12.5%—
statistical stretch, 0.25 median16.9% +4.4 pts
statistical stretch, 0.40 median20.4% +7.9 pts
statistical stretch applied twice16.9% +4.4 pts
gamma 0.3314.0%+1.5 pts
log10 (deliberately unfair)14.8% +2.3 pts

A few points per cent, against a 12.5% floor that is inherent to the method rather than to the stretch. And the cost falls as the gradient grows: at a gradient equal to the sky level the stretched cases scored 5.2% against the linear baseline's 12.7%, because a bigger signal swamps the degeneracy between your gradient and real sky structure. Subtracting a sky-fitted surface does not damage the bright end either — error on the stars came out lower than error on the sky.

These are simulations. They establish that the shape of the problem is benign, not that any particular real image will come out well. Two caveats are real: a stretch that clipped the black point has destroyed part of the background outright, and nothing recovers that; and a spatially varying edit is not one transfer function, so the tangent argument above does not apply to it at all.

3.8 Can the reference resolve your gradient?

Separate question from §3.9, and not covered by it. A reference quantised so coarsely that the sky sits on one or two levels can still produce a perfectly healthy \( b \) — fitted to a staircase. FITS tiles are preferred wherever a tree publishes them, but some trees are 8-bit only, so the resolution is measured directly from the data: the quantisation step is found from the gaps between distinct values, and the modelled background is reported in units of that step.

Noise decides how much that costs. If the per-pixel scatter is wider than one step, sky pixels straddle several levels and averaging a sample patch recovers structure far finer than the step — the quantisation is dithered. If the scatter is narrower, every sky pixel reads the same integer and the structure is simply gone. Four verdicts follow:

VerdictMeans
ample32+ steps, or 8+ steps with dithering. Nothing to think about.
coarse8 or more steps but undithered. The gradient's shape is described; its amplitude is described in that many discrete steps. Prefer a FITS tree if one covers the field.
coarse-ditheredFewer than 8 steps, but noise wider than a step. Patch averaging recovers sub-step structure — shape usable, amplitude soft.
pinnedFewer than 8 steps and undithered. The reference cannot resolve your gradient. Flagged with a warning on the run summary.

Measured on M81 with a 256 px work grid: the DSS2 red FITS tree gave a background spanning 91 quantisation steps with noise 48× the step (ample), while CDS's 8-bit DSS2 colour composite gave 8.5 steps with noise 0.88× the step (coarse) on the same field. Both are usable; only one of them is comfortable.

This is measured from the pixels rather than inferred from the tile format, so it also covers a reference you supply yourself — which is the case where nobody knows what the data has been through.

3.9 Is the reference actually doing anything?

The run summary splits the background structure between the two components that describe it. Write \( E \) for the amplitude the reference accounted for and \( R \) for what was left over — your gradient:

E = |b| \cdot \mathrm{span}(B_r)\,,\qquad R = \mathrm{span}(G)\,,\qquad \mathrm{share} = \frac{E}{E + R}

So the survey's share and yours sum to 100%, and neither can exceed it.

Earlier versions divided \( E \) by \( R \) alone, which could report a reference explaining 164% of the gradient. That was not a display bug but a real one, and the reason is worth knowing: spans do not add. \( \mathrm{span}(X + Y) \) equals \( \mathrm{span}(X) + \mathrm{span}(Y) \) only when \( X \) and \( Y \) are perfectly correlated, and a fitted component and its residual generally are not — so \( E \) can exceed \( R \) with both being correct measurements of their own component. The ratio of one to the other is then not a fraction of anything. For a least-squares fit the exact orthogonal decomposition is in quadrature, \( E^2/(E^2 + R^2) \); the linear form is used here because these spans are robust percentile measures rather than variances (so exact additivity is unavailable either way), and because in the small-\( E \) regime where the warning fires \( E/(E+R) \) tends to \( E/R \), which keeps the 5% trip point calibrated where it already was. Quadrature would have moved it by about a factor of four.

This is the honest self-check, and it is worth reading every time. With a strict veto the reference background can come out nearly flat, \(b\,B_r\) collapses toward a constant, and the method quietly degenerates into ADBE with a survey-derived exclusion mask. That is still a useful tool — but it is not reference-based correction, and the difference should be visible rather than assumed. A survey share near zero means one of:

3.10 Subtraction

The correction is additive, always. The premise is that what the reference fails to explain is additive sky, so dividing it out would be the wrong operator. The gradient is median-centred, scaled by Strength, subtracted, and the original median restored; the result is then rescaled if needed so nothing clips at either end.

3.11 Coverage, and what the failures mean

Pixels outside the survey footprint come back non-finite and are carried through honestly. A pixel is usable only where every reference channel has data, so one channel's footprint edge cannot silently fit against a hole in another. Below 25% coverage the run stops, and the message distinguishes the cases, because they have very different fixes:

3.12 Notes