Recognised text of docs/sources/User Manual V1.0 MTDx61 Dry Contact Series Human Presence Sensor.pdf

User Manual for MTDx61 Dry
contact Series Human
Occupancy Detection Sensor

2
User's manualV1.1
Copyright Description
The hardware, software, and materials referenced in this document are the exclusive property of the
company, and all rights are reserved. The company retains the right to modify this document, the
products described herein, and all associated copyrights. The intellectual property is fully protected
by national law, and any unauthorized use or copying by other companies, organizations, or
individualsisstrictlyprohibitedwithoutthecompany’sexpressauthorization.
Statement
Please read this statement carefully before using the products described in this document. Once
used,itisdeemedarecognitionandacceptanceofthecontentsofthisstatement.
When the user has a sensing sensor, according to the product characteristics, performance and
functions described in this document, they must retest based on their own application to meet the
user's application needs. In case of damage or damage caused by improper use, it shall not bear the
correspondinglossandcompensationliability.
Due to continuous update and iteration, the document may be changed without notice. Please
confirm the update and errata information through appropriate channels during the application. We
havetheultimatepowerofinterpretation.
Please carefully review this statement before using the products described in this document. By
using the products, you acknowledge and accept the contents of this statement.
When using a sensing sensor, users must conduct their own testing based on their specific
application needs, taking into account the product characteristics, performance, and functions
described in this document. The company shall not be held liable for any losses or damages
resulting from improper use or damage caused by the user.
Please note that this document may be updated or revised without prior notice due to continuous
updates and iterations. Please check for updates and errata information through appropriate
channels during use. The company reserves the right to interpret this statement.

3
User's manualV1.1
Safety Precautions
Safety Signs
The following safety marks are used in this manual.
Safety Signs Instruction
When used improperly, it will cause dangerous conditions, which is very likely to lead to
personal injury or death.
When used improperly, it will cause dangerous conditions, may lead to personal injury or
death and equipment damage.
Read carefully and follow the instructions for equipment operation
Before starting the operation, please carefully read the operation instructions and precautions to
reduce the occurrence of accidents. The "care, attention, warning, danger" items in the product and user
manual do not represent all safety matters observed and serve only as a supplement to various
operational safety precautions. Therefore, the product installation, operation personnel must be through
strict training, master the correct operation methods of the system and various safety precautions, before
the operation of the equipment.
In the operation of the company's products and equipment, we must comply with the safety
specifications of the relevant industry, and strictly observe the relevant equipment precautions and special
safety instructions.
Electrical Safety
This manual covers the installation and use of the MTDx61 Dry contact series of human presence
sensors.
Please strictly observe all the warning signs and operation instructions in this manual and do not
operate the equipment without reading all the safety instructions and operation instructions.
warning
1.MTDx61 Dry contact series human presence sensor must be installed and debugged by the manufacturer or its
authorized agent, otherwise it may endanger personal safety and lead to sensor failure of MTDx61 Dry contact series.
The resulting MTDx61 Dry contact series human body sensor damage, is not covered by warranty.
2. This product adopts internal non-isolated power supply, and it is strictly prohibited to install or remove the equipment.
3. It is strictly prohibited to put the MTDx61 Dry contact series human body sensor in the fire to avoid explosion and
endanger personal safety.
4. It is strictly forbidden to dismantle and repair without permission.

4
User's manualV1.1
Precautions for Use
Please read and understand carefully before you use it
It is forbidden to use MTDx61 Dry contact series human body sensors in elevator, metal plate room (less than 6m 6m)
and metal sealed toilet; it is not recommended to use the plane area of metal decorative material in the area exceeding
20%. The above scenario and sensor features can lead to abnormal usage.
It is forbidden to install MTDx61 Dry contact series human body sensors and routers or other high-power WIFI
equipment close to them. For installation spacing requirements, refer to 5.4 Installation principles.
When deploying intensively in large space, please deploy in strict accordance with the spacing requirements. refer to 5.4
Installation principles for details.
MTDx61 Dry contact series human body sensor is ceiling embedded installation, horizontal installation is not
recommended, affecting the detection effect.
Caution
1. The standard model MTDx61 Dry contact series human body has sensors connected with external AC electric
power. Before this operation, it must be operated under power failure, which must be operated by professionals, and
private operation is prohibited.
2. Use environment and preservation methods have a certain impact on the service life and reliability of MTDx61 Dry
contact series human body sensors, and avoid the long-term use of MTDx61 Dry contact series human body
sensors in the following working environment:
The high temperature, low temperature or damp places beyond the specified technical index of the product
Places with conductive dust, corrosive gas, salt spray, or combustible gas
Vibrating, vulnerable places
Close to the heat source or in places with strong electromagnetic field interference
3. Liquid or other foreign objects are not allowed to enter the MTDx61 Dry contact series human body sensor.
4. If a fire occurs around the equipment or equipment, first cut off the power supply; a dry powder fire extinguisher
must be used to extinguish the fire, and the liquid fire extinguisher will risk electric shock.
5. If not used for a long time, the MTDx61 Dry contact series human presence sensor must be stored in a dry
environment. Storage temperature and humidity range of the standard model MTDx61 Dry contact series human
body presence sensor: -20℃ ~ + 65℃, 40 ~ 60% RH.

5
User's manualV1.1
Cataloge
CopyrightDescription..........................................................................................................................2
Statement.............................................................................................................................................2
SafetyPrecautions................................................................................................................................3
1. ProductParameter..........................................................................................................................6
2. InterfaceSizeInterfacesizeInterfacesiz........................................................................................9
3. Install............................................................................................................................................10
4. productuse....................................................................................................................................12
5. CommonProblemsandSolutions................................................................................................17
6. SpecialInstructionsfortheSensor...............................................................................................19
7. RemoteControlSettingParameters.............................................................................................21

6
User's manualV1.1
1. Product Parameter
1． Main Parameter
product model
5.8GHz 24GHz
MTD061-RC MTD261-RC
Parameter item Description
Physica
l
paramet
ers
productsize The maximum diameter oftheouter edge ofthedrycontact is 50mm, theheight is37mm, and a circularholewithadiameterof40-42mmisopened
colour Ceramic white
weight ≤30g
Inducti
on
paramet
ers
BeamAngle 120×120°,theangle ofthesignal energy at 3dB(0.5times) 115×115°,the angle of the signal energy at 3 dB(0.5times)
Topmount:
detectionradius
Respiratorydetectionradius:2.5～3m
Micromotiondetectionradius:3~4m
Movementdetectionradius:4~5.5m
Respiratorydetectionradius:2～3m
Micromotiondetectionradius:3~4m
Movementdetectionradius:4~4.5m
Topmount:
mountingheight
Typicalheight:2.7m～3.5m
sensitivity
1~9;Minimumsensitivity1,highestsensitivity9;default7
explanatorynote:
0Turnoffthesensordetection,thelargerthevalue,themoresensitive,thesensitivitywithin6
canonlyachievemotiondetection,7-9canachievebreathdetection,thereliabilityofthe
existenceisrelatedto"unmanneddelay"(seetherecommendedparameterconfigurationin
differentscenariosforcorrespondingSettings).
detectionrange
1.5-10m;thedefaultmaximumdetection
distanceis6m 1.5~10m;thedefaultprobedistanceis7m
explanatorynote:
1.Detectiondistancereferstothelongestdistanceofthesensorfromthestraightlinethatcan
detectthemovement,micromovementandbreathingtarget,andthemaximumdiameterorradius
notmappingtotheground.
2.Thedistanceisnon-absolutedistance,thesensordetectionhasadistanceresolution,the
resolutionisabout1m.If3misset,itisnormaltotriggerinthe ± 1mintervalatthe3m
position.
3.Thedistancevalueismainlyusedasfilterglasspartition,gypsumboardandwoodpartition,
andisnotstrictlyusedasthedetectionarea.If3misset,theremaybemissingreportandfalse
touchat3mposition ± 1m.
delaytime
5s~25min;itisrecommendednottobelessthan15seconds,toosmallandeasytomissthe
report
explanatorynote:
Thisdelayindicates:1.Thesensortriggersthetimetoleave;2.Thesensortriggerswithinthe
delaytimeandcontinuestoextend.3.Intheobservationwindowofthesensor,thelongerthe
delay,thesmallertheprobabilityofsensoromission,andtherespiratorydetectiondelayisnot
lessthan60s.
Test:Itisrecommendedtosetthedelayof5s&10stoavoidthelongwaitingtime.
lightsense
0～250Lux
explanatorynote:
Thedetectionvalueisnottheabsolutevalueofambientlight,whichislimitedbytheinstallation
direction,illuminationAngleandotherfactors,andcanonlyroughlyreflectthetrendofambient
brightness.
gangcontrol Supportlinkagecontrolanddynamicconfigurationoflinkageparameters

7
User's manualV1.1
system
paramet
er
mi
cro
wa
ve
service
frequency 5.8GHz ± 75MHz,intheISMband 24GHz ± 125MHz,intheISMband
(Pt)Transmit
tingpower
(Pt)
3～5dBm 10dBm
Modulation
mode FMCW、CW
working
conditi
ons
workingvoltage DC9-36V,Typical12V DC9-36V,Typical12V
operatingpower ＜ 1W
working
temperature -10℃~+50℃
Storage
temperature -20℃～65℃
Workinghumidity 5～90%RH
Workaltitude 0-3500m
Protectionlevel IP20
output Outputmethod Relayoutput;Voltage ≤ 24V,current ≤ 100mA Relayoutput;Voltage ≤ 24V,current ≤ 100mA
others
Installation
requirements
Installationheight:2.7-3.5m;Installationmethod:embedded;Holesize:circularholewitha
diameterof40-42mm
inputterminal
Wireharnessconnection,equippedwith0.1mwireharness,itisrecommendedtouseterminal
blocksforextension
Limitusage
scenarios
Insidetheelevator,metalslabroom(lessthan
6m6m)andmetalsealedtoilet,theplanearea
ofmetaldecorativematerialsoutsidethe
ceilingexceeds20%.
Inelevatorsandmetalsealedtoiletsinall
metalsealedspace;morethan20%ofmetal
decorativematerialsintheareaoutsidethe
ceiling.

8
User's manualV1.1
2． Detection Range: Top Mount
Thefollowingfigureisaschematicdiagramofthedetectableareaofthehumanbodyfacingthe
sensorwhen"topmounted".
"Micro-movement" detection area: can detect micro-movement (head, wave, hand, light start,
turn over the book, left and right front and back slightly tilt and other small movements), movement
(walking,trot,running,circle,jumpmovement),existence(standingstill,squattingmotionless);
"Existence" detection area: can detect the standing still, squatting still, sitting still and other
humanbodyinthestaticstate.
The Motion detection
The "Micromotion" detection
he "Breathing" detection area
Thesuctiontop
installation
2.7~3.5m
5.8Gradarmodule
Detectioncoveragerange(relatedtoinstallationheightandsensitivity
parameters):
Detectionradiusduringtopinstallation:2-3metersforhumanbreathing
Detectionradiusduringtopinstallation:3-4mforhumanbodymicro
movement
Detectionradiusduringtopinstallation:humanbodymovementof4-4.5
meters
24Gradarmodule
Detectioncoveragerange(relatedtoinstallationheightandsensitivity
parameters):
Detectionradiusduringtopinstallation:2.5to3metersforhumanbreathing
Detectionradiusduringtopinstallation:3-4mforhumanbodymicro
movement
Detectionradiusduringtopinstallation:humanmotion4-5.5m
Note: 1. The above range value is based on the conclusion of 3m, 10 x10m length and width, and
parameterconfiguration:sensitivity7-9.Withadelayof60sandadetectiondistanceof9m,different
sceneswillhavecertaindifferences.
2.The detectable radius is related to many factors such as the installation environment, human size,
relativeAngle,andmicro-motion/motionrange.Theaboveparametersarethetestresultsofsensors
used by our tester. The descriptions of small movements and movements are qualitative, not
quantitative,forreferenceonly. Under different test conditions, please refer to the actual test.

9
User's manualV1.1
2. Interface SizeInterfacesizeInterfacesiz
2.1 Interface
2.2 Size
TheMTDx61drycontact sensorseriesadoptsanembeddedceilinginstallationmethod,withan
outeredgeof50mm;Thesizeoftheembeddedceilingpartis:diameter × High=40 × 35mm.
Serial Number colour function
1 red Positive pole of power supply
2 black Negative pole of power supply
3 white S1
4 green S2
S1
Positive pole of power supply
Negative pole of power supply
S2


10
User's manualV1.1
2.3 Wiring
Connect the external power and signal wires tothe sensor's built-inharness and introduce them
intotheceilingopening.
3. Install
3.1InstallationMethod1:EmbeddedInstallation
1. According to the scope and shape of the area to be tested, select a suitable installation
locationontheceilingtoensurethatthetestingareacanbeeffectivelycovered.
2. The edge diameter of the equipment is 50mm, and the embedded part is 40 * 35mm
(cylindrical). Circular holes with a diameter of 40-42mm can be opened on the ceiling, and the
minimumreservedspaceatthetopisnotlessthan50mm.
3. Clip the power and signal cables onto the equipment (gently clip the cables, otherwise they
maybeeasilycut)andintroducethemintotheceilingopening.
4.Insertthedeviceintotheceilingholetocompletetheinstallation.
dc power
control signal
40mm
installationdiagram

11
User's manualV1.1
3.2InstallationMethod2:BracketInstallation
1.According tothe scope and shape of the area to be tested, select a suitableinstallation locationon
thewalltoensurethatthetestingareacanbeeffectivelycovered.
2. Fix the sensor on the installation bracket, and according to the installation angle of the sensor,
make wire harness holes and bracket fixing holes on the wall. The wire harness through-hole is a
circularholewithadiameterof8mm.
3. The fixed hole diameter of the equipment installation bracket is 5mm, and a circular hole with a
diameter of 5mm can be opened on the wall. The bracket is fixed with matching expansion screws,
andtheminimumreservedspaceatthetopisnotlessthan50mm.
4. Introduce the power and signal wires into the bracket opening and clip them onto the reserved
wiringharnessoftheequipment(gentlyclipthewires,otherwisetheymaybeeasilycut)tocomplete
theinstallation.
Installationdimensionidentificationdiagram
Wire harness through-hole on the bracket, with a
diameter of 8mm
The product comes with a wiring harness,
with a diameter of 4mm
Bracket fixing hole with a diameter of 5mm
installationdiagram

12
User's manualV1.1
4. product use
4.1 Output signal access to user system
Connect the sensor's reed output terminals S1 and S2 to the user system; Choose the appropriate
accessplanbasedonthespecificsituation:
(1)Fourwirefullyisolatedaccessmethod:
S1 and S2 terminals have no electrical connection with the sensor. When the presence of a human
body is detected, S1 and S2 terminals are connected; Otherwise, S1 and S2 terminals are
disconnected;
Reminder:Refer tothe"ExplanationofReedOutputSignal" sectionofthe"OrderingandSelection"
section
4.2 Sensor power supply
Provide 9 V DC power supply for sensors with suffix DC; Provide 9-24 V DC power supply for
sensors with suffix RC; DC power can be supplied centrally using a switching power supply or
separatelyusingapoweradapter.
4.3 Using the Remote Control to Configure Parameters
Using a remote control to configure the parameters of the MTDx61 dry contact series sensors
facilitateson-siteinstallation,debugging,andmaintenancemanagement.
(1) Configure parameters such as "detection distance", "sensitivity", "delay time", and "light
intensity";
Tip:Refertothe"RemoteControlSettingParameters"sectionofChapter7

13
User's manualV1.1
4.4 Recommended Parameter Configuration for Different
Scenarios
scene
Scenario
requirem
ents
installation
requirements
Parameter configuration
suggestions
notes
porch /
corridor
Dressing
Room
Microacti
vemotion
detection
and
motion
detection
1.Regionalcenter
Sensitivity:1~9;
detectionrange:
Familyporch2.5-3.5m;
Publicarea:3.5~9m;
Someonetonoonedelayfor
morethan20s.
Porch, corridor, dressing room
normally the personnel stay time is
relativelyshort,themovementrange
is obvious, the actual scene only
needs the movement triggered to
meet the demand, such as special
demand stay for a long time or the
public area has a conversation
scene, improve sensitivity, elongate
"someonetonodelay"can
kitchen
Respirator
y
detection
micromoti
on
detection
motion
detection
Kitchen: in the
center of the
kitchen, stay away
from the exhaust
fans, glass doors
andWindows,etc
Sensitivity:6~9;
Thedetectiondistanceis
2.5~4m;
Someonetonoonedelayof
morethan30s.
1.Inthekitchenscene,therearefew
people completely motionless.
"Someone to no delay" can be set
slightlyshorter
Family
bathroom
lavatory
Respirator
y
detection
micromoti
on
detection
motion
detection
Sanitary room and
toilet: away from
doors and
Windows, away
from exhaust fan;
0.4-0.6m of toilet
/ squat in front of
the roof,
comprehensive
evaluation.
Sensitivity:7~9;
Probedistanceof2.5~3.5m;
1. Someonetonoonedelayof
morethan60s.
This kind of scene generally has a
small area, and people may be in a
static state for a long time. It needs
to do respiratory detection, high
sensitivity needs to be set, and
special attention is paid to the glass
door when setting the detection
distance.
saloon
dining
room
assembly
micromoti
on
detection
motion
Living room:
0.5~1m position
infrontofthesofa
Dining room: the
Sensitivity:7~9;
Detectionrangeof4~9m;
Someonetonoonedelayof
Living room, meeting room scene,
theareaisrelativelylarge,personnel
sitting, lying completely motionless,
sensitivity and distanceneed to set a

14
User's manualV1.1
room detection center location of
thediningtable
Conference room:
on the central axis
of the long side of
themeetingtable
morethan60s. highvalue.
The dining room scene is small and
large, and the actual scene overlaps
with the living room or open
kitchen. It is necessary to set an
appropriate distance to achieve a
betterexperience.
bedroom
study
micromoti
on
detection
motion
detection
Bedroom: within
thebedarea
Study:insidethe
0.6-1.5mbefore
andafterthedesk
Sensitivity:8-9;
Detectiondistanceof5.5-9m;
Delayofmorethan180seconds
fromsomeonetonoone.
Bedroomscenario:usersspendmost
of sleep, reading and rest time, with
less movement; breath detection
requires high sensitivity, and long
delaytokeepthesensornottomiss.
Under the study scene:peoplearein
a state of reading or working for a
long time, and they also need to
detect breathing to judge the
existence of people. It needs high
sensitivity. The distance setting is
considered according to the area of
the actual scene and the potential
source of interference
comprehensively.
Please refer to the above table for setting the scene parameters, otherwise the best sensor effect
cannotbeachieved!

15
User's manualV1.1
4.5 Installation Principle
(1)Porch/aisle,changingclothesroomscene:center,fixedfirmly.
(2)Kitchen scene: in the center, fixed firmly. For example, when the installation area is square,
there is an open glass door on the long side, and if the central installation position is just
opposite the glass door, you need to re-select the position. At this time, the door piercing
problem can be solved by installing the sensor on the side position of the solid wall on the
sideofthedoor,andtheexperiencewillnotbeaffectedaftersettingtheappropriatedistance.
(3)Home bathroom and toilet scene: stay away from doors andWindows; 0.4-0.6m in front of the
toilet / squat location covering the whole scene space; microwave signal can penetrate the
glass door or wooden door by solve the sensor on the side wall of the door. The actual
positioningrequirescomprehensiveevaluationonsite.
(4)Livingroom/ diningroom /meetingroomscene: Livingroom:0.5~1m infront ofsofa; dining
room:tablecenter;conferenceroom:onthelongcentralaxisofmeetingtable.
(5)Bedroom, study scene: Bedroom: in the area directly above the bed; study: in the 0.6-1.5m
beforeandafterthedesk.
(6) Other types of scenarios
1 Longandspecial-shapedareascenario:bothsidesofthelongsideofthelongarea(long
side is less than 10m); if the long side is glass or gypsum board, and the long side is less than 1.3
times, the solid wall can be more than 1.3 times, two sensors shall be installed in sections; if the
longsideisglassorgypsum board,thelongandremoteareaislargerthanthesensor,andthearea
shallbedividedandtheaboveprinciplesshallbeobserved.
2 Glass and gypsum board partition: Keep away from glass and partition test, and try as
close to the solid wall on the premise that the sensor can meet the breathing area to be covered.
For example,the surrounding isglass and partition installedin themiddle, and set theappropriate
detection distance, indent distance, trigger sensitivity to solve the detected outside the glass and
thewall.
3 People sitting, squatting, standing in the motionless scene: sensor top, 0.4-0.8m in front
ofthefrontofthehead.Shouldnotbedirectlyontheheadposition.
4 Intensivedeploymentscenario:thesensorisnotlessthan4m.

16
User's manualV1.1
4.6 Common Interference Sources and Solutions
(1)Fan: fan shaking head (blade diameter greater than 10cm), metal fan without shaking head,
ceilingfan.
Thefan blade greater than10cm causes thesensor tocontinuouslyoutput thehuman state;
the metal blade fan can trigger or maintain the human state output of the sensor when working;
and the plastic blade fan without shaking the head can be filtered by the sensor in areas other
thantheareaofthebreathdetection.Settingappropriatetriggersensitivitycaneffectivelyavoid
someinterferencetriggersensoroutput.
(2)Air conditioning: the air swing of the hang and cabinet, the metal ornaments blown by the air
conditioning, the thick curtain blown by the air conditioning, the ceiling vibration driven by
theceilingairconditioning,theshuttervibrationofthecentralairconditioner.
Theairswingandlouvervibrationoftheairconditionercantriggerormaintainthehuman
state of the sensor within the breathing coverage of the sensor; the air conditioner can also
trigger or maintain the human state of the sensor. Setting appropriate trigger sensitivity and
trigger indent can avoid most false triggers; but it cannot completely solve the problem that
interferencecausesthesensortocontinuouslyoutputhumanstateafterhumanleave.
(3)Curtains:curtainsthatswaysignificantly,rollerblindswithaluminumalloybottomrails.
Small swing curtains such as cloth, cotton, and sand curtains used in ordinary households
arenoteasytotriggersensors;Iftherollershutterwithaluminumalloylowerrailswingswithin
the detection distance range, it is easy to trigger the sensor. By setting an appropriate detection
distance and filtering out such interference, it is possible to effectively avoid false triggering
causedbytheabovescenarios.
(4)Drain fan: ceiling vibration caused by metal fan leaf and exhaust fan of exhaust fan. If the
sensor cannot be triggered without the diameter of the front side of the sensor, the ceiling
vibration caused by the exhaust fan drives the sensor vibration or the vibration surface
detectedbythesensorwillbetriggered.
(5)Strong5.8GHzWiFisignalinterference:5.8GHzWiFirouter/APinthefrontareaofthesensor,
or5.8GHzWiFirouter/APinthehorizontalor1.5mofthesensor.
It is recommended that theWiFi router inthe front area of the sensor be installed over 3m
from the sensor; the other direction shall be separated above 1.5m from the sensor; and the
top-mountedAPshallbeseparatedabove1.5mfromthesensor.

17
User's manualV1.1
(6)Air flow (wind): the movement, movement and vibration of objects in the scene caused by
blowingmaycausethetrigger.
Settingtheappropriatetriggersensitivitycanfilterthewindandgrassbelow2-3,thelargerthe
windlevel,themorelikelytotrigger.
(7)Animals: cats, dogs, mice, other pets, etc. The difference between other animal species and
humancharacteristicsisinthatofthebodysize,suchastheanimalbodysizeandhumanbody,
andthetriggeringmechanismandhumanbodyarealsoconsistent.
Set the appropriate trigger sensitivity and trigger indent distance, most of the kitten and
puppy mice are unable to trigger the sensor. Such as the curtains caused by cats and dogs, or
clothes,sheets,quiltcoversdragging,themovementofobjectswillalsotriggersensors.
(8)Low frequency vibration: wall or ceiling vibration caused by high sound volume, vibration
causedbyupstairsanddownstairsdecoration,etc.
When installation, it is necessary to maintain a suitable distance with the stereo to avoid
the radar signal directly hitting the main stereo. When choosing the installation position, the
main consideration is to cover the stationary area, such as sofa, seat, etc. Set a relatively low
sensitivity (avoid mistriggering) and a longer 'human to no delay' to achieve more reliable
detection.
5. Common Problems and Solutions
frequently asked question cause analysis resolvent
Afterconnectingtothe
powersupply,thesensor
indicatorlightdoesnot
respond
1. Isthepowersupplynormaland
meetstheworkingvoltageofthe
sensor?
Checkifthepowersupplymeetsthe
workingvoltageofthesensor
2.Istheindicatorlightdamaged?
Contactafter-salespersonnelandreturnto
thefactoryforrepair
Inthepresenceofsomeone,
the sensor cannot detect
someone
1.Isthedetectionareasettoosmall?
Resetthematchingdetectionareabased
onthescene
2.Isthesensitivitysettingtoolow?
Adjustthecorrespondingsensitivity
accordingtothescenario

18
User's manualV1.1
3.Isthesensorinstalledproperly?
Ensurethatthesensorisinstallednormally
withoutobstruction,ensuringthatthe
sensorisinstallednormallywithout
obstruction
4.Isthedelaytimesettooshort? Ensureadelaytimeof30secondsormore
Sensorsdetectsomeonein
anunmannedstate
1.Isthereanyinterferencesourceinthe
environment?
Eliminateinterferencesourcesinthe
environment
2.Isthedetectionareatoolarge?
Resetthematchingdetectionareabased
onthescene
3.Isthesensitivitysettingtoohigh?
Adjustthecorrespondingsensitivity
accordingtothescenario

19
User's manualV1.1
6. Special Instructions for the Sensor
Duetothecharacteristicsofmicrowavetechnology,theidealdetectionresultswillnotappearin
some application scenarios, or the ideal detection results should be obtained under the right
conditions.
TheMTDx61drycontactseriessensorsaresensorswithhighdetectionperformance,whichcan
detect microdynamic changes that cannot be seen by the human eye. If you encounter a different
performance than expected in the test, please contact us to provide detailed technical support, so as
not to affect the use of parameter setting errors, and the sensor is unable to play the best detection
performance.
The default configuration parameters of MTDx61dry contact series sensors are not suitable for
the actual scenarios of all users. Please be sure to reconfigure the sensor parameters so that the
working parameters of the sensor are suitable for the use scenarios to achieve better test effect and
performance.
1. Detectiontechnology:Weakmotiondetectiontechnologyattherespiratorylevel:
(1) The current version of the sensor can detect the fluctuation range as low as 1 mm or speed as low as 3
mm/s,andmosthumanbreathingmovement,bodymicromovement,itsfluctuationrangeismuchgreater
than 1 mm or more than 3 mm / s, so it can be highly sensitive to identify whether there is a human
body;
(2) Fromtheusepointofview,itcanbeunderstoodasmotiondetectionwithhighersensitivitybutlowerfalse
positiverate,andcanstablyandreliablydetectweakundulatingmovementssuchasrespiration.
2.Limitationsofthe"weakmotiondetectiontechnology":
(1)Dithering air conditioners, fans, washing machines; shaking curtains, green plants; shaking large
metal equipment, ventilation pipes, fire pipes, drainage pipes; motion frequency or harmonic
frequencyofinvisiblevibrationinhumaneyesfallsintothehumanrespiratoryfrequencyrange,and
maybeobservedbysensorsandmistakenfor"humanbodyexistence";
(2) Eliminatetheinterferenceofshakingorshakingobjects,andexcludetheinterferenceareabysetting
the maximum detection distance, or by adjusting the mounting position to prevent the beam from
directly or indirectly reflecting the interference. Or for the presence of a fixed interference source,
thegeneralversionofthesensorcannotsolve,theinterferencealgorithmcanbecustomizedtofilter
theinterferenceinterference(suchaselectricfan,airconditioning,bathbully,etc.).
3.Relativemovementisrequired:
(1)Because the sensor has the highest sensitivity to the radial motion (relative motion) of the target
detection, the longest detection distance, and it is easier to detect the target. Therefore, the best
installation method is: horizontal installation> oblique downward installation> top installation;
however, when using the detection function, top installation is recommended, because horizontal
installationandobliquedownwardinstallationwillhaveacertaindetectionblindarea.

20
User's manualV1.1
(2) Ontop,thebestrelativemovementisupanddown;themotionintheupperandlowerdirection;
(3)Top loading, a certaindistance fromthesensor of the human body, the beam is oblique irradiation to
the body, the level of the body in the upper and lower direction of the movement component, so it
candetectthepresenceofpeople;
(4)At the top, sitting directly under the sensor and the body does not shake, only breathing movement,
because the breathing movement is horizontal movement, there is no movement component in the
upper and lowerdirection, the sensor willnot detect the presence of someone. In this case, the
sensor delay time is generally increased, so that in a longer observation time, the probability of the
human body directly under the sensor becomes smaller, then the probability of detecting the
existenceofthehumanbodywillincrease,andtheomissionrateisreduced;
(5) Horizontalinstallation:onlyirradiationtothefoot,willnotbeabletodetectthehumanpresence.
4. SensorAngle
(1) Electromagneticwaves,likeaflashlight,haveenergy beyondtheedge,andthelightneartheedgeis
there, but relatively weak. For example, the sensor of 120120,120 represents the antenna radiation
angle, which is the angle measured when the signal energy is 0, not the target detection angle that
can be detected, and the central cross section of the detection area is not a triangular detection
surfacelikeanopening120.
(2) The size and distance of the detection area are related to the volume, relative angle, and motion
speedofthedetectedtarget.Forhorizontalinstallation:thelargerthetargetvolume,theeasieritisto
be detected; The smaller the relative angle (such as forward relative motion), the easier it is to be
detected.
5. signalenhancement
Due to the multi-path propagation effect of the signal microwave, the reflection signal will be
enhanced in the closed and many obstacle environment, so that the sensor detection performance is
better. Set the same configuration parameters in a small area will be better than a large area
conferenceroom;smallroomswillbebetterthanthehall.

21
User's manualV1.1
7. Remote Control Setting Parameters
The dry contact version of the sensor also supports remote control configuration
parameters, on-site installation, debugging, and maintenance management
1． Remote control instructions
2． Supplementary instructions for function keys
(1) 【ON/OFF】key：
Userscanusethisbuttontomaketheoutputsignalnormallyopenornormallyclosed.
(2) 【lock】 key：
Thesensorisinthe"unlocked"statebydefaultatthefactory,anduserscandirectlyoperate
it using the remote control. During normal use of the sensor, if encountering interference
from the remote control of other electrical appliances, the sensor can be locked by long
pressingtoprohibitremotecontroloperation.
(3) 【 Reset/RestoreFactory 】 key
Whenthesensorisinthemanualremotecontroloutputorclosedoutputstate,pressthe
resetbuttontorestorethesensortotheinductionoutputstate;Longpressthisbuttonto
restorethesensorparameterstothedefaultstate:sensitivity7,detectiondistance6meters,
anddelaytime15seconds.
(4) 【 Lightsensitivity 】 key:
Shortpresstoconfigurethelightsensitivity,withavaluerangeof0-45Lux;Ifthelight

22
User's manualV1.1
sensingfunctionisnotrequired,configurethelightsensingvalueto255or0toturnoffthe
lightsensingfunction.
Longpresstheconfigurationtotriggertheindentationdistance,withavaluerangeof0-9m
andadefaultof0.6m.Thelargerthevalue,themoreindentation,andthesmallerthe
triggeringradius,andviceversa.
(5) 【Sensitivity】 key:
Shortpresstheconfigurationtomaintainsensitivity,withavaluerangeof0-9andadefault
of7.Thehigherthevalue,thehigherthesensitivity.
Longpresstheconfigurationtotriggersensitivity,withavaluerangeof0-9andadefaultof
5.Thelargerthevalue,thehigherthesensitivity.
(6) 【ConfirmDelay】 key
1) The configurable value range is 0-10s, with one decimal place remaining
valid. Excess decimal points and decimal values will be ignored by the sensor.
2) The confirmation time after detecting the target and configuring the optimal
parameter values can greatly reduce the false alarm rate. Although the higher
the value, the more reliable it is, when a true target appears, the sensor
needs to take a longer time to report that the target has been detected.
(7) 【 DisappearanceDelay 】 key:
1) The configurable value range is 0.5~1500s, with one decimal place remaining valid.
Excess decimal points and decimal values will be ignored by the sensor.
2) The delay time after "target disappearance", the larger the configured parameter
value, the easier it is to reduce missed alarms caused by accidental target
disappearance. Although the higher the value, the more reliable it is, when the target
truly disappears, the sensor needs to take a longer time to report that the target
has disappeared. For scenarios where the response speed requirement is not high after
the target disappears, it is recommended to set it to more than 15 seconds or longer,
such as 30 seconds, 60 seconds, 90 seconds, etc.
(8) 【 farthestdistance 】 key:
1) Short press to configure the farthest detection distance: value range 0-9m,
default to 7m
5.8G radar module: value range 0-10m, default 7m;
24G radar module: value range 0-12m, default 7m;

23
User's manualV1.1
2) Long press to configure the nearest detection distance
5.8G radar module: value range 0-10m, default 0.6m;
24G radar module: value range 0-12m, default 2m;
Sensors will only detect targets located between the closest and farthest
distances. For example, if the nearest distance is 1 meter and the farthest
distance is 3 meters, the sensor will not detect targets within 1 meter or
greater than 3 meters.
(9) 【OK】 key:
After pressing the [Light Sensitivity], [Sensitivity], [Delay], or [Maximum Distance] keys
on the remote control, input the parameter values. Finally, press the [Confirm] key before
thesensorwillstoreandusethenewparametervalues,otherwisetheywillnotbeused.
(10)【•/Buzzer】key:
Thedefaultbuzzerison,andasoundwillsoundwhentheremotecontrolbuttonispressed.
If the buzzer needs to be turned off, long press and hold the button to turn off the buzzer;
Pressandholdagaintoturnonthebuzzer.
(11)【 0/LEDswitch 】 key:
The default LED indicator light turns off when working normally, and flashes or lights up
when abnormal. Long press and hold this button to turn off the indicator light (it will still
flash when the remote control is in use), and it will no longer flash or light up in case of
abnormalities.Pressandholdagaintoturnontheindicatorlight.
(12) Quickparameterconfiguration:Userscanquicklyconfiguretypicalparametersbylong
pressingthesebuttons.
[Configuration 1] key, with the following parameters, suitable for scenarios such as
bathroomsandkitchens:
Sensitivity: 6;Thenearestdetectiondistanceis0.9m;Thefarthestdetectiondistanceis
2.4m;Targetconfirmationtimeis0.2seconds;Delaytimeof20seconds;
[Configuration 2] key, with the following parameters, suitable for scenarios such as
studyandbedroom:
Sensitivity: 8, nearest detection distance 0.9m, farthest detection distance 3m, target
confirmationtime0.5s,delaytime120s;
[Configuration 3] key: The parameters are as follows, suitable for living rooms, halls,
conferencerooms,andotherspaces:

24
User's manualV1.1
Sensitivity: 7;Thenearestdetectiondistanceis0.6m;Thefarthestdetectiondistanceis
6m;Targetconfirmationtime0.1;Delaytimeof60seconds;
(13) 【BatteryProtectionSheet】:
Before using the remote control, please remove the plastic sheet that isolates the battery to
ensure that the remote control is powered on and working properly. It is recommended to
keep the plastic sheet and insert it back when the remote control is not frequently used to
protectit.
Reminder:
(1)After pressing the [Light Sensitivity], [Sensitivity], [Delay], or [Maximum Distance] buttons, if
thereisnooperationwithin5seconds,thesensorwilltimeoutandexittheconfigurationstate;
(2) 【 • 】, 【 0 】, 【 1 】, 【 2 】, 【 3 】, 【 4 】, 【 5 】, 【 6 】, 【 7 】, 【 8 】,
【 9 】 arenumericalcombinationkeysusedforparametervalueinput.
3.Example
(1)Setsensitivityto8:
Operation steps: In the remote control unlocking state, first press the [Sensitivity] key to
entertheconfigurationstate, thenpressthenumberkey[8],andfinallypressthe[Confirm]
keytotakeeffect.
(2)Ifthemaximumdetectiondistanceissetto6.5meters:
Operation steps: In the remote control unlocking state, first press the [farthest distance]
buttontoentertheconfigurationstate,thenpressthenumberkey[6],decimalpointkey[•],
numberkey[5],andfinallypressthe[confirm]buttontotakeeffect.
(3)Toquicklyconfiguretheparametersofparametergroup2:
Operationsteps: In the remote control unlocking state, press the [8/Configuration 2] button
formorethan3seconds.
(4)Restorefactoryconfiguration:
Press the 'Restore Factory' button for more than 3 seconds while the remote control is
unlocked.