Metadata-Version: 2.5
Name: aerosmart-modbus
Version: 0.3.5
Summary: A typed Modbus device model for aerosmart ventilation/heat-pump units
Project-URL: Homepage, https://github.com/kayloehmann/aerosmart-modbus
License: Apache-2.0
License-File: LICENSE
Requires-Python: >=3.12
Requires-Dist: modbus-connection<5,>=4.12
Provides-Extra: cli
Requires-Dist: modbus-connection[pymodbus]<5,>=4.12; extra == 'cli'
Description-Content-Type: text/markdown

# aerosmart-modbus

A typed, async Python model of an aerosmart ventilation/heat-pump unit's
Modbus registers. Backend-neutral: built on
[modbus-connection](https://pypi.org/project/modbus-connection/), so it runs
over pymodbus, tmodbus, or an in-memory mock -- no Home Assistant dependency.
A Home Assistant integration that consumes this library lives in a separate
repository.

## Features

- 137 registers across 16 sub-systems, transcribed 1:1 from a live
  installation's Modbus register map (address, scale, unit).
- Two Modbus units modelled as one device: unit 1 (ventilation controller,
  which also aggregates most fault/request flags) and unit 2 (heat pump /
  domestic hot water), read together via one `AerosmartDevice` object.
- Neutral per-field metadata (`value_kind`, `writable`, `description`,
  `source_key`) -- no Home Assistant concepts leak into this layer.
- Pooled block reads per unit (`ComponentGroup`), not one Modbus round-trip
  per register.
- A regression test that re-parses the original source YAML and checks every
  Python field's address/scale still matches it (see "Development", below --
  there is no manufacturer register manual to check against instead).

## Device structure

| Attribute | Unit | Sub-system |
|---|---|---|
| `general` | ventilation | weekday, time/date, software version, device type |
| `outside_temperature` | ventilation | outside air temperature + thresholds |
| `room_temperature` | ventilation | room air temperature + setpoint |
| `fans` | ventilation | fan speeds, run hours, faults |
| `ventilation` | ventilation | operating mode, airflow, shading/frost/de-icing |
| `cooling` | ventilation | cooling thresholds |
| `summer_bypass` | ventilation | summer bypass automation |
| `carbon_dioxide` | ventilation | CO2 sensor |
| `fine_dust_filter` / `coarse_dust_filter` | ventilation | filter run time / change flags |
| `fire_alarm` | ventilation | fire alarm system contact |
| `aggregate_fault` | ventilation | summary fault flags |
| `boost_functions_ventilation` | ventilation | HEIZUNG+ boost function (ventilation-side registers) |
| `hot_water_ventilation` | ventilation | hot water fault/request flags (as seen from the controller) |
| `utility_lockout` | heat pump | utility (EVU) lockout signals |
| `heat_pump` | heat pump | compressor, pressures, run hours, status |
| `boost_functions_heat_pump` | heat pump | BAD+ boost function (heat-pump-side registers) |
| `hot_water_heat_pump` | heat pump | boiler temperatures, hot water setpoint |

## Basic usage

```python
import asyncio
from modbus_connection.pymodbus import connect_tcp
from aerosmart_modbus import AerosmartDevice


async def main():
    connection = await connect_tcp("192.0.2.10", port=8899)
    device = AerosmartDevice(
        connection.for_unit(1),  # ventilation
        connection.for_unit(2),  # heat pump
    )
    await device.async_update()
    print(device.outside_temperature.temp_aussenluft, "°C outside")
    print(device.heat_pump.wp_status)


asyncio.run(main())
```

## Known hardware quirk: request pacing

Live-tested against a real unit: this device sits behind a slow
RS232-to-Modbus-TCP gateway. Issuing requests back-to-back with no pacing at
all made the gateway return responses under stale/mismatched transaction IDs,
and most reads timed out. `AerosmartDevice` therefore asks the shared Modbus
transport for 300ms of quiet before and after either unit's requests and a
one-second settle delay after connecting. Consumers do not need to add sleeps
or configure connection timing themselves.

The device exposes `async_update_readings()` and `async_update_settings()` so
consumers can poll operating data and the controller clock frequently while
reading filter counters and slow-changing settings on a longer interval.
`async_update()` still refreshes everything. Each returns an `UpdateReport`,
allowing one failed sub-system to become unavailable without discarding fresh
data from the others.

## Metadata and writes

Every field carries a `DatapointMetadata` (see `metadata.py`):
`value_kind` (`"number"`, `"boolean"`, or `"enum"`), `writable`,
`verified_writable`, `description` (the original German label), `source_key`
(the original Home Assistant entity id it was transcribed from, for
traceability), and the matching value metadata.

```python
meta = device.hot_water_heat_pump.require_metadata_for("wp_brauchwasser_soll_temp")
meta.writable  # True
meta.verified_writable  # True
meta.source_key  # "aerosmartm_wp_brauchwasser_soll_temp"

actual = await device.async_write_verified(
    "hot_water_heat_pump", "wp_brauchwasser_soll_temp", 52.0
)
```

Use `async_write_verified()` for consumer-facing controls. It only accepts
registers whose write semantics and limits are confirmed by the manufacturer
documentation, serializes writes across both controller units, validates the
value, and reads the register back immediately. `writable=True` without
`verified_writable=True` remains an unverified transcription and is rejected
by this safe API.

## Command-line query tool

```bash
python -m pip install -e ".[cli]"
python script/query.py tcp 192.0.2.10 --port 8899
```

Prints every sub-system's current values, plus how many Modbus reads it took.
Not used by CI -- a manual diagnostic tool for probing a real unit.

## Development

```bash
uv sync
uv run pytest
uv run ruff check .
uv run ruff format .
```

Tests run against `modbus_connection`'s in-memory mock (no real device
needed) plus a YAML consistency check (`tests/test_yaml_consistency.py`)
against the original source fragments under `tests/fixtures/aerosmartm/`.
Tested against `modbus-connection` 4.12.x. Project metadata accepts compatible
releases from 4.12 up to, but excluding, 5.