AEROX AIRCRAFT SOURCE NOTES
Aircraft: Embraer 500 Phenom 100
ICAO: E50P
Last reviewed: 2026-11-24
Source ledger: sources/sources.yml

CERTIFICATION SCOPE
  Model or family: EMB-500, commercial generation unresolved
  Authority: Agencia Nacional de Aviacao Civil
  Type certificate: EMB-500 certificate; exact current ANAC identifier not resolved in this batch
  Applicability: Phenom 100/100E/100EV/100EX generation and weight option unresolved.

TYPE-CERTIFICATE AND LIMIT PARAMETERS

FIELD certification.model
  Value: EMB-500, commercial generation unresolved
  Status: certified-published
  Source: anac_ct_transfer_portaria_7380_2022
  Applicability: Phenom 100/100E/100EV/100EX generation and weight option unresolved.
END FIELD

FIELD certification.authority
  Value: Agencia Nacional de Aviacao Civil
  Status: certified-published
  Source: anac_ct_transfer_portaria_7380_2022
  Applicability: Phenom 100/100E/100EV/100EX generation and weight option unresolved.
END FIELD

FIELD certification.type_certificate
  Value: EMB-500 certificate; exact current ANAC identifier not resolved in this batch
  Status: certified-published
  Source: anac_ct_transfer_portaria_7380_2022
  Applicability: Phenom 100/100E/100EV/100EX generation and weight option unresolved.
END FIELD

FIELD certification.issue
  Value: null
  Status: unresolved
  Source: -
  Reason unavailable: No exact-scope value was adopted from the reviewed qualified primary source; the document omits it, defers it, or the bundled model/variant remains ambiguous.
END FIELD

FIELD certification.issue_date
  Value: null
  Status: unresolved
  Source: -
  Reason unavailable: No exact-scope value was adopted from the reviewed qualified primary source; the document omits it, defers it, or the bundled model/variant remains ambiguous.
END FIELD

FIELD mtow
  Value: 4855
  Unit: kg
  Status: certified-published
  Source: easa_ima157_issue_09
  Page or section: Issue 09, item 9, p. 9
  Applicability: EMB-500 with the weight increase of note 14
  Notes: Basic: 4,750 kg; note 9: 4,800 kg.
END FIELD

FIELD mlw
  Value: 4535
  Unit: kg
  Status: certified-published
  Source: easa_ima157_issue_09
  Page or section: Issue 09, item 9, p. 9
  Applicability: EMB-500 with the weight increase of note 14
  Notes: Basic: 4,430 kg.
END FIELD

FIELD mzfw
  Value: null
  Unit: kg
  Status: unresolved
  Source: -
  Reason unavailable: No exact-scope value was adopted from the reviewed qualified primary source; the document omits it, defers it, or the bundled model/variant remains ambiguous.
END FIELD

FIELD minimum_weight
  Value: null
  Unit: kg
  Status: unresolved
  Source: -
  Reason unavailable: No exact-scope value was adopted from the reviewed qualified primary source; the document omits it, defers it, or the bundled model/variant remains ambiguous.
END FIELD

FIELD vmo
  Value: 275
  Unit: kt
  Status: certified-published
  Source: easa_ima157_issue_09
  Page or section: Issue 09, item 6, p. 8
  Applicability: EMB-500
  Notes: VMO 275 KIAS, MMO 0.7.
END FIELD

FIELD mmo
  Value: 0.7
  Unit: Mach
  Status: certified-published
  Source: easa_ima157_issue_09
  Page or section: Issue 09, item 6, p. 8
  Applicability: EMB-500
  Notes: VMO 275 KIAS, MMO 0.7.
END FIELD

FIELD ceiling
  Value: 41000
  Unit: ft
  Status: certified-published
  Source: easa_ima157_issue_09
  Page or section: Issue 09, item 7, p. 8
  Applicability: EMB-500
END FIELD

WING AND TAIL GEOMETRY

FIELD wing.area
  Value: 18
  Unit: m2
  Status: legacy-unverified
  Source: aerox_legacy_aircraft_database
END FIELD

FIELD wing.span
  Value: 12.3
  Unit: m
  Status: legacy-unverified
  Source: aerox_legacy_aircraft_database
  Applicability: Phenom 100EX only
  Searched source: embraer_phenom100ex_brochure_2023
  Notes: Candidate is explicitly the Phenom 100EX; the bundled EMB-500 commercial generation is unresolved.
END FIELD

FIELD wing.mac
  Value: 1.6
  Unit: m
  Status: legacy-unverified
  Source: aerox_legacy_aircraft_database
END FIELD

FIELD wing.sweep
  Value: 0
  Unit: deg
  Status: legacy-unverified
  Source: aerox_legacy_aircraft_database
END FIELD

FIELD wing.t/c
  Value: 0.12
  Unit: nondimensional
  Status: legacy-unverified
  Source: aerox_legacy_aircraft_database
END FIELD

FIELD wing.root_chord
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD wing.tip_chord
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD wing.taper_ratio
  Value: null
  Unit: nondimensional
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD wing.aspect_ratio
  Value: 8.405
  Unit: nondimensional
  Status: legacy-unverified
  Source: aerox_legacy_aircraft_database
  Formula: span^2 / area
  Inputs: span=12.3 m; area=18 m2
END FIELD

FIELD wing.dihedral
  Value: null
  Unit: deg
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.area
  Value: null
  Unit: m2
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.span
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.mac
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.root_chord
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.tip_chord
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.taper_ratio
  Value: null
  Unit: nondimensional
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.sweep
  Value: null
  Unit: deg
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.dihedral
  Value: null
  Unit: deg
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.arm
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD horizontal_tail.elevator_area_ratio
  Value: null
  Unit: nondimensional
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.area
  Value: null
  Unit: m2
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.height
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.mac
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.root_chord
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.tip_chord
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.taper_ratio
  Value: null
  Unit: nondimensional
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.sweep
  Value: null
  Unit: deg
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.arm
  Value: null
  Unit: m
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

FIELD vertical_tail.rudder_area_ratio
  Value: null
  Unit: nondimensional
  Status: unresolved
  Source: -
  Reason unavailable: No exact-model public value has been adopted.
  Searched source: anac_ct_transfer_portaria_7380_2022 | embraer_phenom100ex_brochure_2023
  Search record: reviewed current official Phenom 100EX and Phenom 300E brochures. Rows are restricted to those commercial generations and are not back-applied to every EMB-500/EMB-505.
END FIELD

LEGACY PARAMETERS
  Parameters not listed above retain the original Aerox database values.
  Unless a source is named above, those values remain legacy-unverified.

DRAG MODEL
  Active Aerox physical drag model and reference-condition polar snapshot.
  Scaled or substituted geometry fields: horizontal_tail.area, horizontal_tail.mac, vertical_tail.area, vertical_tail.mac, wing.root_chord, horizontal_tail.sweep, vertical_tail.sweep, engine.fan_diameter, engine.nacelle_max_diameter, engine.nacelle_length

FIELD drag.model
  Value: aerox-geometry-drag-v2
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Inputs: configuration=clean; tier=B-observed-core-scaled-tails; confidence=medium-low; e_span=0.9436; roughness_excrescence/computed=0.0900; nacelle_tier=C-estimated-fan-diameter
  Zero-lift terms at reference (drag counts): wing=70.39; fuselage=75.89; horizontal_tail=22.95; vertical_tail=14.56; nacelles=8.67; pylons=1.16; fuselage_upsweep=5.89; control_surface_gaps=1.40; nacelle_base=3.61; roughness_excrescence=18.41
  Applicability: Active clean model; geometry-tier uncertainty applies.
END FIELD
FIELD drag.configuration
  Value: clean
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Model metadata; not a measured aircraft coefficient.
END FIELD
FIELD drag.geometry_tier
  Value: B-observed-core-scaled-tails
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Model metadata; not a measured aircraft coefficient.
END FIELD
FIELD drag.confidence
  Value: medium-low
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Model metadata; not a measured aircraft coefficient.
END FIELD
FIELD drag.reference_altitude_ft
  Value: 50917.8
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Representative clean reference condition.
END FIELD
FIELD drag.reference_mach
  Value: 0.7
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Representative clean reference condition.
END FIELD
FIELD drag.reference_reynolds_per_m
  Value: 2591761.1
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Inputs: altitude=50917.8 ft; Mach=0.700000; ISA temperature and density
END FIELD
FIELD drag.span_efficiency_factor
  Value: 0.943624
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Physical model input; geometry-tier uncertainty applies.
END FIELD
FIELD drag.unresolved_fraction_of_resolved_drag
  Value: null
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Physical model input; geometry-tier uncertainty applies.
END FIELD
FIELD drag.roughness_excrescence_fraction
  Value: 0.09
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Physical model input; geometry-tier uncertainty applies.
END FIELD
FIELD drag.wave_drag_model
  Value: aerox-korn-lock-wave-v1
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Model metadata; not a measured aircraft coefficient.
END FIELD
FIELD drag.wave_drag_source_tier
  Value: D-class-scaled
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Model metadata; not a measured aircraft coefficient.
END FIELD
FIELD drag.wave_drag_confidence
  Value: low
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Model metadata; not a measured aircraft coefficient.
END FIELD
FIELD drag.wave_drag_technology_factor
  Value: 0.95
  Status: project-derived-active-model
  Source: aerox_geometry_drag_model_2026_08_08
  Applicability: Physical model input; geometry-tier uncertainty applies.
END FIELD
END DRAG MODEL