The Library panel keeps processed maps side by side, so you can plot them again, lay several over each other, join measurements of different spectral or field ranges, or average repeated sweeps.
…_Data.csv is Data; R(B)/R(0) otherwise).0.25T, 0.50T, …); off, loaded tables take the Sample panel's custom field range.There is no limit to the number of maps. Hover over a map's name to see where it came from.
Tick a map to show it. Ticked maps are drawn together on the map, each on its own field and energy range; the one ticked (or clicked) last is on top. Click a map to bring it on top; a click on the top map plots it again (with the Processing panel's baseline region). The maps on the plot are highlighted in the list, the top one is framed, and the plot head and the status bar name them (R(B)/R(0) · FIR over MIR). The plot's ranges fit all of them while they are on Auto, and Fit to data does the same.
Where maps overlap, the ones above the lowest are drawn with the Overlap opacity (50 % at first; the slider sits above the list), so you can see how they line up; everywhere else each map shows in full colour. All maps share the colour scale of the top one, so only maps of the same kind as the top one are drawn below it: a map that is not drawn says why in its row (another kind, or no data within its limits or the baseline region).
The top map is the one you work with: the Stacked tab shows its spectra, and you pick points on it, fit models to it and export it like a processed sweep. Picks beyond its field range do not go to the maps below.
Each map opens to its limits: E min and E max (in the unit shown) and B min and B max (in tesla). An empty limit means no cut; a limit that holds none of the map's data is marked. With Plot the full ranges off, the maps are plotted cut to their limits, redrawn when you pause typing or press Return.
Process shows the processed sweep again and keeps the ticks; Show next to Maps brings the ticked maps back, and Show in the Processed sweep box goes back to the sweep without processing it again.
The Combine section at the bottom of the panel joins the ticked maps, each cut to its E and B limits, into a product. With fewer than two ticked maps it takes one line; its arrow folds it away. Choose how:
Before you create it, the section shows what the product will be (fields, field and energy range, number of energies, where the maps join), or why the maps cannot be combined, for example maps of different kinds or with different fields. Create product makes it and shows it.
The Product box shows its name, which you can edit, the maps it was made of with their limits, its size and how the maps were joined. Its buttons:
<file>_provenance.txt says how it was made and with which baseline region.A new product replaces the one before; the × discards it.