Grid & Inverter

Grid connection, import/export power-plane limits, and the inverter's real charge/discharge limits.

read-only

Grid import & export limits Guide

cmdType 1701 · full-block RMW · read-back verified · values in W, entered in kW

What is known about the local 1701 write (one site, aGate X-01-AU):
  • Debug Mode on, firmware V12R02B60D00 (2026-10-23): stored — it read back the values written. Whether the aGate enforces it (clamps a grid charge) is not yet tested.
  • Debug Mode off, earlier firmware (2026-09-28): ignored — it ACKed result:0 but did not store or take effect (a 2 kW cap did not clamp a 4 kW grid charge).
  • Debug Mode off, V12R02B60D00: not yet tested.
Installer power settings are made in Debug Mode (FranklinWH Commissioning Guide). The read-back shows what the aGate stored. The cloud global caps (setPowerControl) are a separate plane.
Grid import cap gridSoftLimit
Charge from grid kwRatePower
Grid export gridExportEnable / gridHardLimit
PCS discharge isPcsDischgEn

You're changing an export/discharge enable — the FranklinWH procedure says test those last, one at a time, with the owner watching.