         Cost╺┫ ┃
 (0.00367/m³) ┃/┣╸alpha
              ┃/┛ (2, fixed)



     ┃┓
     ┃┃
     ┃┃
     ┃┣╸A_wall = 200m²
     ┃┃
     ┃┛
     ┃┓
 Box╺┫┃
     ┃┃
     ┃┣╸A_wall ≥ 2·h·w + 2·h·d
     ┃┃
     ┃┛
     ┃┣╸alpha = 2
     ┃┛
     ┃┣╸alpha ≤ h/w
     ┃┛


Optimal Cost
------------
1/(Box.h·Box.w·Box.d) : 0.003674 [1/m³]

Free Variables
--------------
Box
d : 8.17  [m] depth
h : 8.163 [m] height
w : 4.081 [m] width

Fixed Variables
---------------
Box
A_floor : 50  [m²] upper limit, floor area
 A_wall : 200 [m²] upper limit, wall area
  alpha : 2        lower limit, wall aspect ratio
   beta : 10       upper limit, wall aspect ratio
  delta : 10       upper limit, floor aspect ratio
  gamma : 2        lower limit, floor aspect ratio

Variable Sensitivities
----------------------
Box
A_wall : -1.5 upper limit, wall area
 alpha : +0.5 lower limit, wall aspect ratio

Most Sensitive Constraints
--------------------------
Box
+1.5 : A_wall ≥ 2·h·w + 2·h·d
+0.5 : alpha ≤ h/w