Metadata-Version: 2.4
Name: radiuma_suv
Version: 1.0.2
Summary: PET DICOM to body-weight-normalized standardized uptake value (SUVbw) conversion
Author: Mohammad R. Salmanpour, Ramin Afrah, Mehrdad Oveisi, Arman Rahmim
License: MIT License
        
        Copyright (c) 2026 radiuma-suv contributors
        
        Permission is hereby granted, free of charge, to any person obtaining a copy
        of this software and associated documentation files (the "Software"), to deal
        in the Software without restriction, including without limitation the rights
        to use, copy, modify, merge, publish, distribute, sublicense, and/or sell
        copies of the Software, and to permit persons to whom the Software is
        furnished to do so, subject to the following conditions:
        
        The above copyright notice and this permission notice shall be included in all
        copies or substantial portions of the Software.
        
        THE SOFTWARE IS PROVIDED "AS IS", WITHOUT WARRANTY OF ANY KIND, EXPRESS OR
        IMPLIED, INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY,
        FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT. IN NO EVENT SHALL THE
        AUTHORS OR COPYRIGHT HOLDERS BE LIABLE FOR ANY CLAIM, DAMAGES OR OTHER
        LIABILITY, WHETHER IN AN ACTION OF CONTRACT, TORT OR OTHERWISE, ARISING FROM,
        OUT OF OR IN CONNECTION WITH THE SOFTWARE OR THE USE OR OTHER DEALINGS IN THE
        SOFTWARE.
        
Project-URL: Repository, https://github.com/radiuma-com/radiuma_suv
Project-URL: Issues, https://github.com/radiuma-com/radiuma_suv/issues
Classifier: Programming Language :: Python :: 3
Classifier: Operating System :: OS Independent
Classifier: Intended Audience :: Science/Research
Requires-Python: >=3.10
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: numpy>=1.24
Requires-Dist: pydicom>=3.0
Requires-Dist: SimpleITK>=2.3
Provides-Extra: dev
Requires-Dist: pytest>=8; extra == "dev"
Requires-Dist: build>=1.2; extra == "dev"
Requires-Dist: ruff>=0.8; extra == "dev"
Dynamic: license-file

# radiuma_suv: PET to SUVbw Conversion – Python Script and Library

**PyPi:**  [Link](https://pypi.org/project/radiuma_suv/)

**GitHub:**  [Link](https://github.com/radiuma-com/radiuma_suv) 

**radiuma_suv** is the proposed library name for the PET-to-SUVbw conversion engine in `src/radiuma_suv/core.py`. The code converts PET pixels to **body-weight-normalized standardized uptake values (SUVbw)** using DICOM acquisition and radiopharmaceutical metadata. It supports conventional single-frame PET, Enhanced multi-frame PET, NumPy arrays with matching DICOM metadata, and folders containing one or several PET series. In-memory results are floating-point arrays; DICOM results are newly written, calibrated derived images.

**Code Overview:** `radiuma_suv` is a Python-based PET-to-SUVbw conversion tool that converts PET image pixel values into body-weight-normalized Standardized Uptake Values (SUVbw) using DICOM metadata. It supports conventional single-frame PET, Enhanced multi-frame PET, NumPy arrays, and DICOM directories containing multiple PET series.

The code provides three main interfaces:

- **`radiuma_suv(input_array, input_metadata, parameter_estimation="OFF")`**: Converts a 2D/3D PET NumPy array into a floating-point SUVbw array and returns the corresponding metadata dictionary.
- **`radiuma_suv_from_input(image_input, parameter_estimation="OFF", output_path=None)`**: Automatically detects supported PET inputs and produces SUVbw outputs in the corresponding format (NumPy array or derived DICOM file/directory).
- **`RadiumaSUVLoader(parameter_estimation="OFF", pet_metadata=None, output_path=None)`**: Provides an object-oriented interface for PET-to-SUVbw conversion through the `.convert(image_input)` method.

**Parameter Estimation:** `"OFF"` uses existing DICOM metadata without filling missing fields, while `"ON"` fills eligible missing metadata using predefined configuration values. Original DICOM files are not overwritten.

**Scientific caution:** `parameter_estimation="ON"` can fill missing metadata with notebook-configured values, including patient weight, radionuclide activity, timing, and other acquisition details. Those values must not be assumed correct for another patient. Prefer `"OFF"` with complete verified source DICOM metadata. No clinical validation is established by the notebook.

## 🔍 Table of Contents

- [🎥 YouTube Tutorials](#-youtube-tutorials)
- [🧩 IBSI Standardization & Calibration](#-ibsi-standardization--calibration)
- [✨ Key Features](#-key-features)
- [📚 Library Usage](#-library-usage)
    - [💻 Standalone Mode](#standalone-mode)
    - [🔗 Embedded Mode](#embedded-mode)
- [📥 Installation](#-installation)
- [📂 Data Structure Requirements](#-data-structure-requirements)
- [📋 Synthesize Missing Inputs](#-synthesize-missing-inputs)
- [📊 Parameter Compatibility](#-parameter-compatibility)
- [📚 API Reference](#-api-reference)
- [📊 Output Structure](#-output-structure)
- [📁 Supported File Formats](#-supported-file-formats)
- [🎯 Library Examples](#-library-examples)
- [⚡ Performance Tips](#-performance-tips)
- [❓ Troubleshooting](#-troubleshooting)
- [🕒 Version History](#-version-history)
- [📬 Contact](#-contact)
- [👥 Authors](#-authors)
- [📚 Citation](#-citation)
- [🙏 Acknowledgment](#acknowledgment)
- [📜 License](#-license)

## 🎥 YouTube Tutorials

Watch our tutorial videos on our [YouTube channel](https://www.youtube.com/@Radiuma-software)
- Video 1 (coming soon)


## 🧩 IBSI Standardization & Calibration

We have [three versions of the software/code](https://github.com/radiuma-com/radiuma_suv/tree/main/IBSI-Calibration/IBSI-Validated-Code-Versions) for [IBSI Compliance-SUV Calibrations](https://theibsi.github.io/ibsi-suv/).
-	[Version 1](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Code-Versions/Version1.ipynb): before the start of IBSI-SUV
-	[Version 2](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Code-Versions/Version2.ipynb): Calibrated with the first standardization attempt and with the first 17 DROs.  
-	[Version 3](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Code-Versions/Version3.ipynb): Calibrated with the second standardization attempt and with all 58 DROs.
IBSI calibration datasets are available for [download](https://github.com/oncoray/suv_computation)

Report of Calibrations

**Calibration 1 (Just the First 17 DROs)**

- Use Code Version 2 and the first 17 DROs.
  - [Result 1, called Version 2_Calibration 1.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%201%2C%20called%20Version%202_Callibration%201.csv)
    - **Note:** We already submitted this result, but we include it in this collection for your easy access.
          

**Calibration 2 (All 58 DROs)**

- Use Code Version 3 and all 58 DROs. 
  - [Result 2, called Version 3_Callibration 2.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%201%2C%20called%20Version%202_Callibration%201.csv)

 - Use Code Version 2 and all 58 DROs. 
   - [Result 3, called Version 2_Callibration 2.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%202%2C%20called%20Version%203_Callibration%202.csv)

 - Use Code Version 1 and all 58 DROs. 
   - [Result 4, called Version 1_Callibration 2.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%203%2C%20called%20Version%202_Callibration%202.csv)

**Calibration 3 ( All 16 Real Patients: Final Validation Phase)**
 - Use Code Version 3 and all 16 real patients (Validation phase). 
   - [Result 5, called Version 3_Callibration 3.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%204%2C%20called%20Version%201_Callibration%202.csv)

 - Use Code Version 2 and all 16 real patients (Validation phase). 
   - [Result 6, called “Version 2_Callibration 3.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%206%2C%20called%20Version%202_Callibration%203.csv)

 - Use Code Version 1 and all 16 real patients (Validation phase). 
   - [Result 7, called “Version 1_Callibration 3.csv](https://github.com/radiuma-com/radiuma_suv/blob/main/IBSI-Calibration/IBSI-Validated-Results/Result%207%2C%20called%20Version%201_Callibration%203.csv)


## ✨ Key Features

- **PET-to-SUVbw conversion** using PET image pixels and matching DICOM metadata.
- **Conventional PET DICOM**: single-frame PET images and conventional PET slice series.
- **Enhanced PET DICOM**: multi-frame images with functional group metadata.
- **NumPy arrays**: convert in memory using a corresponding DICOM metadata dictionary.
- **Hierarchical PET directories**: recursively identify PET DICOM groups and process independent series separately.
- **Type-preserving API**: NumPy input returns a NumPy array; DICOM input creates derived DICOM outputs.
- **Optional metadata completion**: `parameter_estimation="ON"` fills selected missing values using notebook settings.
- **Derived DICOM output**: new DICOM identifiers, calibrated signed 16-bit pixels, and output validation against computed SUVbw values.
- **Source protection**: output paths are checked to avoid overwriting original DICOM files.
- **Object-oriented convenience wrapper**: `RadiumaSUVLoader`.

These are implementation capabilities, not independent quantitative or clinical validation claims.

### 📦 Library Installation via pip

After publishing the intended package under the distribution name `radiuma_suv`:

```bash
python -m pip install radiuma_suv
```

For local development in the directory containing `pyproject.toml`:

```bash
python -m pip install -e .
```

## 📚 Library Usage

### Script Execution

The `radiuma_suv` code supports two execution modes: **Standalone Mode** and **Embedded Mode**.

#### Standalone Mode

Run the Python script directly to convert PET DICOM images into SUVbw.

**Step 1: Choose the input path and options at the CLI (do not edit the installed library):**

```bash
radiuma_suv PATH_TO_PET_DICOM_FILE_OR_FOLDER --parameter-estimation OFF
```

**Step 2: Alternatively execute using Python:**

```bash
python -m radiuma_suv PATH_TO_PET_DICOM_FILE_OR_FOLDER --parameter-estimation OFF
```

**Output:** Creates calibrated SUVbw DICOM files in a new `_processed` location without overwriting original images.

#### Embedded Mode

Import the conversion functions into another Python application, pipeline, or GUI.

**Option A: DICOM file or directory**

```python
from radiuma_suv import radiuma_suv_from_input

output, metadata = radiuma_suv_from_input(
    image_input="PET_Input",
    parameter_estimation="OFF",
    output_path="SUV_Output"
)
```

```python
from radiuma_suv import radiuma_suv_from_input

output, metadata = radiuma_suv_from_input(
    image_input="PET_Input",
    parameter_estimation="ON",
    output_path="SUV_Output"
)
```
**Note**: If parameter_estimation is set to ON, missing parameter values in the DICOM header are synthesized based on the input image.
## DICOM and PET Image Parameters

### 1. Patient Information

| Parameter | Default Value | Description |
|---|---|---|
| `PatientWeight` | `"75.5"` | Patient weight (kg). |
| `PatientAge` | `"045Y"` | Patient age (DICOM AS format). |
| `PatientSize` | `"1.75"` | Patient height (m). |
| `PatientSex` | `"M"` | Patient sex (DICOM: M/F/O). |

### 2. Radiopharmaceutical Information

| Parameter | Default Value | Description |
|---|---|---|
| `RadionuclideTotalDose` | `"370000000"` | Administered radiopharmaceutical dose. Conventional PET: Bq; Enhanced PET: MBq. Must be verified against the source IOD. |
| `RadionuclideHalfLife` | `"6586.2"` | Radionuclide half-life (s). Must match the actual tracer. |
| `RadiopharmaceuticalStartTime` | `"093015"` | Administration start time (TM, HHMMSS). Deprecated; full DateTime is preferred. |
| `RadiopharmaceuticalStartDateTime` | `"20261010093015"` | Administration start date and time (DT). |
| `RadionuclidePositronFraction` | `"0.967"` | Radionuclide positron fraction (range: 0–1). |
| `RadiopharmaceuticalSpecificActivity` | `"1000000000"` | Specific activity (Bq/µmol). |
| `RadiopharmaceuticalVolume` | `"5.0"` | Administered radiopharmaceutical volume (cm³). |
| `RadiopharmaceuticalStopTime` | `"093115"` | Administration stop time (TM). Deprecated; full DateTime is preferred. |
| `RadiopharmaceuticalStopDateTime` | `None` | Standard DICOM stop date and time (DT), tag (0018,1079). Use the actual recorded stop datetime. |

### 3. Acquisition and Timing Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `ActualFrameDuration` | `"180000"` | Acquisition frame duration (ms). |
| `FrameReferenceTime` | `"90000"` | Frame reference time (ms). |
| `AcquisitionDate` | `"20261010"` | Acquisition date (DA, YYYYMMDD). |
| `AcquisitionTime` | `"100000"` | Acquisition time (TM, HHMMSS). |
| `SeriesDate` | `"20261010"` | Series date (DA, YYYYMMDD). |
| `SeriesTime` | `"095500"` | Series time (TM, HHMMSS). |
| `FrameTime` | `"1000"` | Frame time (ms); conditional on acquisition type. |
| `TriggerTime` | `"0"` | Trigger time (ms); conditional on acquisition type. |
| `NominalInterval` | `"800"` | Nominal interval (ms); conditional on gated acquisition. |
| `IntervalsAcquired` | `"1000"` | Number of intervals acquired; conditional. |
| `IntervalsRejected` | `"10"` | Number of intervals rejected; conditional. |
| `NumberOfTimeSlices` | `"1"` | Number of time slices; conditional. |
| `NumberOfTimeSlots` | `"1"` | Number of time slots; conditional. |

### 4. Pixel Value and SUV Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `Units` | `"BQML"` | PET pixel-value units (e.g., BQML, GML, CM2ML, CNTS). |
| `SUVType` | `"BW"` | SUV normalization type (e.g., BW). |
| `RescaleSlope` | `"1.0"` | Stored-pixel rescale slope (DS). |
| `RescaleIntercept` | `"0.0"` | Stored-pixel rescale intercept (DS). |
| `PhilipsSUVScaleFactor` | `None` | Philips vendor-private SUV scaling factor; not a public DICOM keyword. |
| `PhilipsActivityConcentrationScaleFactor` | `None` | Philips vendor-private activity concentration scaling factor; not a public DICOM keyword. |

### 5. Decay and Correction Factors

| Parameter | Default Value | Description |
|---|---|---|
| `DecayCorrection` | `"START"` | Decay correction reference (START, ADMIN, NONE). |
| `DecayFactor` | `"1.2"` | Decay factor actually applied. |
| `DoseCalibrationFactor` | `"1.0"` | Dose calibration factor actually applied. |
| `SliceSensitivityFactor` | `"1.0"` | Slice sensitivity correction factor actually applied. |
| `ScatterFractionFactor` | `"0.25"` | Scatter fraction correction factor actually applied. |
| `DeadTimeFactor` | `"1.05"` | Detector dead-time correction factor actually applied. |

### 6. Count Statistics and Correction Methods

| Parameter | Default Value | Description |
|---|---|---|
| `PrimaryPromptsCountsAccumulated` | `"10000000"` | Accumulated primary prompt counts. |
| `SecondaryCountsAccumulated` | `"1500000"` | Accumulated secondary counts. |
| `CorrectedImage` | `["ATTN", "SCAT", "DECY", "RAN"]` | Applied image correction codes (DICOM multi-valued CS). |
| `RandomsCorrectionMethod` | `"DLYD"` | Randoms correction method (e.g., DLYD). |
| `AttenuationCorrectionMethod` | `"CT-based attenuation correction"` | Attenuation correction method. |
| `ScatterCorrectionMethod` | `"Model-based scatter correction"` | Scatter correction method. |
| `ReconstructionMethod` | `"OSEM"` | Image reconstruction method. |

### 7. Image Geometry and Spatial Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `Rows` | `256` | Number of image rows. Must match the NumPy array dimensions. |
| `Columns` | `256` | Number of image columns. Must match the NumPy array dimensions. |
| `PixelSpacing` | `[4.0, 4.0]` | Pixel spacing in row and column directions (mm). |
| `SliceThickness` | `"3.0"` | Slice thickness (mm). |
| `SpacingBetweenSlices` | `"3.0"` | Distance between adjacent slices (mm). |
| `ImagePositionPatient` | `[0.0, 0.0, 0.0]` | Image position in patient coordinates (x, y, z) in mm. Frame/slice specific. |
| `ImageOrientationPatient` | `[1.0, 0.0, 0.0, 0.0, 1.0, 0.0]` | Row and column direction cosines (6 values). |

### 8. PET Image and Reconstruction Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `SeriesType` | `["STATIC", "IMAGE"]` | PET series type (DICOM multi-valued CS). |
| `CountsSource` | `"EMISSION"` | PET counts source (EMISSION or TRANSMISSION). |
| `ReconstructionDiameter` | `"600.0"` | Reconstruction diameter (mm). |
| `PETFrameCorrectionFactorsSequence` | `None` | Enhanced PET frame correction factors (DICOM SQ). Requires a verified sequence structure. |

### 9. Enhanced PET Correction Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `DecayCorrectionDateTime` | `"20261010100000"` | Enhanced PET decay correction reference date and time (DT). |
| `DecayCorrected` | `"YES"` | Indicates whether decay correction has been applied (YES/NO). |
| `AttenuationCorrected` | `"YES"` | Indicates whether attenuation correction has been applied (YES/NO). |
| `ScatterCorrected` | `"YES"` | Indicates whether scatter correction has been applied (YES/NO). |
| `RandomsCorrected` | `"YES"` | Indicates whether randoms correction has been applied (YES/NO). |

### 10. Application-Specific Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `erode_voxels` | `"0"` | Legacy application-specific setting. Not a DICOM attribute. |

**Option B: NumPy array with DICOM metadata**

```python
from radiuma_suv import radiuma_suv

suv_array, metadata = radiuma_suv(
    input_array=pet_array,
    input_metadata=pet_metadata,
    parameter_estimation="OFF"
)
```
```python
from radiuma_suv import radiuma_suv

suv_array, metadata = radiuma_suv(
    input_array=pet_array,
    input_metadata=pet_metadata,
    parameter_estimation="ON"
)
```
**Note**: If parameter_estimation is set to ON, missing parameter values in the DICOM header are synthesized based on the input image.
## DICOM and PET Image Parameters

### 1. Patient Information

| Parameter | Default Value | Description |
|---|---|---|
| `PatientWeight` | `"75.5"` | Patient weight (kg). |
| `PatientAge` | `"045Y"` | Patient age (DICOM AS format). |
| `PatientSize` | `"1.75"` | Patient height (m). |
| `PatientSex` | `"M"` | Patient sex (DICOM: M/F/O). |

### 2. Radiopharmaceutical Information

| Parameter | Default Value | Description |
|---|---|---|
| `RadionuclideTotalDose` | `"370000000"` | Administered radiopharmaceutical dose. Conventional PET: Bq; Enhanced PET: MBq. Must be verified against the source IOD. |
| `RadionuclideHalfLife` | `"6586.2"` | Radionuclide half-life (s). Must match the actual tracer. |
| `RadiopharmaceuticalStartTime` | `"093015"` | Administration start time (TM, HHMMSS). Deprecated; full DateTime is preferred. |
| `RadiopharmaceuticalStartDateTime` | `"20261010093015"` | Administration start date and time (DT). |
| `RadionuclidePositronFraction` | `"0.967"` | Radionuclide positron fraction (range: 0–1). |
| `RadiopharmaceuticalSpecificActivity` | `"1000000000"` | Specific activity (Bq/µmol). |
| `RadiopharmaceuticalVolume` | `"5.0"` | Administered radiopharmaceutical volume (cm³). |
| `RadiopharmaceuticalStopTime` | `"093115"` | Administration stop time (TM). Deprecated; full DateTime is preferred. |
| `RadiopharmaceuticalStopDateTime` | `None` | Standard DICOM stop date and time (DT), tag (0018,1079). Use the actual recorded stop datetime. |

### 3. Acquisition and Timing Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `ActualFrameDuration` | `"180000"` | Acquisition frame duration (ms). |
| `FrameReferenceTime` | `"90000"` | Frame reference time (ms). |
| `AcquisitionDate` | `"20261010"` | Acquisition date (DA, YYYYMMDD). |
| `AcquisitionTime` | `"100000"` | Acquisition time (TM, HHMMSS). |
| `SeriesDate` | `"20261010"` | Series date (DA, YYYYMMDD). |
| `SeriesTime` | `"095500"` | Series time (TM, HHMMSS). |
| `FrameTime` | `"1000"` | Frame time (ms); conditional on acquisition type. |
| `TriggerTime` | `"0"` | Trigger time (ms); conditional on acquisition type. |
| `NominalInterval` | `"800"` | Nominal interval (ms); conditional on gated acquisition. |
| `IntervalsAcquired` | `"1000"` | Number of intervals acquired; conditional. |
| `IntervalsRejected` | `"10"` | Number of intervals rejected; conditional. |
| `NumberOfTimeSlices` | `"1"` | Number of time slices; conditional. |
| `NumberOfTimeSlots` | `"1"` | Number of time slots; conditional. |

### 4. Pixel Value and SUV Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `Units` | `"BQML"` | PET pixel-value units (e.g., BQML, GML, CM2ML, CNTS). |
| `SUVType` | `"BW"` | SUV normalization type (e.g., BW). |
| `RescaleSlope` | `"1.0"` | Stored-pixel rescale slope (DS). |
| `RescaleIntercept` | `"0.0"` | Stored-pixel rescale intercept (DS). |
| `PhilipsSUVScaleFactor` | `None` | Philips vendor-private SUV scaling factor; not a public DICOM keyword. |
| `PhilipsActivityConcentrationScaleFactor` | `None` | Philips vendor-private activity concentration scaling factor; not a public DICOM keyword. |

### 5. Decay and Correction Factors

| Parameter | Default Value | Description |
|---|---|---|
| `DecayCorrection` | `"START"` | Decay correction reference (START, ADMIN, NONE). |
| `DecayFactor` | `"1.2"` | Decay factor actually applied. |
| `DoseCalibrationFactor` | `"1.0"` | Dose calibration factor actually applied. |
| `SliceSensitivityFactor` | `"1.0"` | Slice sensitivity correction factor actually applied. |
| `ScatterFractionFactor` | `"0.25"` | Scatter fraction correction factor actually applied. |
| `DeadTimeFactor` | `"1.05"` | Detector dead-time correction factor actually applied. |

### 6. Count Statistics and Correction Methods

| Parameter | Default Value | Description |
|---|---|---|
| `PrimaryPromptsCountsAccumulated` | `"10000000"` | Accumulated primary prompt counts. |
| `SecondaryCountsAccumulated` | `"1500000"` | Accumulated secondary counts. |
| `CorrectedImage` | `["ATTN", "SCAT", "DECY", "RAN"]` | Applied image correction codes (DICOM multi-valued CS). |
| `RandomsCorrectionMethod` | `"DLYD"` | Randoms correction method (e.g., DLYD). |
| `AttenuationCorrectionMethod` | `"CT-based attenuation correction"` | Attenuation correction method. |
| `ScatterCorrectionMethod` | `"Model-based scatter correction"` | Scatter correction method. |
| `ReconstructionMethod` | `"OSEM"` | Image reconstruction method. |

### 7. Image Geometry and Spatial Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `Rows` | `256` | Number of image rows. Must match the NumPy array dimensions. |
| `Columns` | `256` | Number of image columns. Must match the NumPy array dimensions. |
| `PixelSpacing` | `[4.0, 4.0]` | Pixel spacing in row and column directions (mm). |
| `SliceThickness` | `"3.0"` | Slice thickness (mm). |
| `SpacingBetweenSlices` | `"3.0"` | Distance between adjacent slices (mm). |
| `ImagePositionPatient` | `[0.0, 0.0, 0.0]` | Image position in patient coordinates (x, y, z) in mm. Frame/slice specific. |
| `ImageOrientationPatient` | `[1.0, 0.0, 0.0, 0.0, 1.0, 0.0]` | Row and column direction cosines (6 values). |

### 8. PET Image and Reconstruction Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `SeriesType` | `["STATIC", "IMAGE"]` | PET series type (DICOM multi-valued CS). |
| `CountsSource` | `"EMISSION"` | PET counts source (EMISSION or TRANSMISSION). |
| `ReconstructionDiameter` | `"600.0"` | Reconstruction diameter (mm). |
| `PETFrameCorrectionFactorsSequence` | `None` | Enhanced PET frame correction factors (DICOM SQ). Requires a verified sequence structure. |

### 9. Enhanced PET Correction Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `DecayCorrectionDateTime` | `"20261010100000"` | Enhanced PET decay correction reference date and time (DT). |
| `DecayCorrected` | `"YES"` | Indicates whether decay correction has been applied (YES/NO). |
| `AttenuationCorrected` | `"YES"` | Indicates whether attenuation correction has been applied (YES/NO). |
| `ScatterCorrected` | `"YES"` | Indicates whether scatter correction has been applied (YES/NO). |
| `RandomsCorrected` | `"YES"` | Indicates whether randoms correction has been applied (YES/NO). |

### 10. Application-Specific Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `erode_voxels` | `"0"` | Legacy application-specific setting. Not a DICOM attribute. |

**Option B: Object-Oriented Integration** 

```python
from radiuma_suv import RadiumaSUVLoader

converter = RadiumaSUVLoader(parameter_estimation="OFF")
output, metadata = converter.convert("PET_Input")
```
```python
from radiuma_suv import RadiumaSUVLoader

converter = RadiumaSUVLoader(parameter_estimation="ON")
output, metadata = converter.convert("PET_Input")
```
**Note**: If parameter_estimation is set to ON, missing parameter values in the DICOM header are synthesized based on the input image.

## DICOM and PET Image Parameters

### 1. Patient Information

| Parameter | Default Value | Description |
|---|---|---|
| `PatientWeight` | `"75.5"` | Patient weight (kg). |
| `PatientAge` | `"045Y"` | Patient age (DICOM AS format). |
| `PatientSize` | `"1.75"` | Patient height (m). |
| `PatientSex` | `"M"` | Patient sex (DICOM: M/F/O). |

### 2. Radiopharmaceutical Information

| Parameter | Default Value | Description |
|---|---|---|
| `RadionuclideTotalDose` | `"370000000"` | Administered radiopharmaceutical dose. Conventional PET: Bq; Enhanced PET: MBq. Must be verified against the source IOD. |
| `RadionuclideHalfLife` | `"6586.2"` | Radionuclide half-life (s). Must match the actual tracer. |
| `RadiopharmaceuticalStartTime` | `"093015"` | Administration start time (TM, HHMMSS). Deprecated; full DateTime is preferred. |
| `RadiopharmaceuticalStartDateTime` | `"20261010093015"` | Administration start date and time (DT). |
| `RadionuclidePositronFraction` | `"0.967"` | Radionuclide positron fraction (range: 0–1). |
| `RadiopharmaceuticalSpecificActivity` | `"1000000000"` | Specific activity (Bq/µmol). |
| `RadiopharmaceuticalVolume` | `"5.0"` | Administered radiopharmaceutical volume (cm³). |
| `RadiopharmaceuticalStopTime` | `"093115"` | Administration stop time (TM). Deprecated; full DateTime is preferred. |
| `RadiopharmaceuticalStopDateTime` | `None` | Standard DICOM stop date and time (DT), tag (0018,1079). Use the actual recorded stop datetime. |

### 3. Acquisition and Timing Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `ActualFrameDuration` | `"180000"` | Acquisition frame duration (ms). |
| `FrameReferenceTime` | `"90000"` | Frame reference time (ms). |
| `AcquisitionDate` | `"20261010"` | Acquisition date (DA, YYYYMMDD). |
| `AcquisitionTime` | `"100000"` | Acquisition time (TM, HHMMSS). |
| `SeriesDate` | `"20261010"` | Series date (DA, YYYYMMDD). |
| `SeriesTime` | `"095500"` | Series time (TM, HHMMSS). |
| `FrameTime` | `"1000"` | Frame time (ms); conditional on acquisition type. |
| `TriggerTime` | `"0"` | Trigger time (ms); conditional on acquisition type. |
| `NominalInterval` | `"800"` | Nominal interval (ms); conditional on gated acquisition. |
| `IntervalsAcquired` | `"1000"` | Number of intervals acquired; conditional. |
| `IntervalsRejected` | `"10"` | Number of intervals rejected; conditional. |
| `NumberOfTimeSlices` | `"1"` | Number of time slices; conditional. |
| `NumberOfTimeSlots` | `"1"` | Number of time slots; conditional. |

### 4. Pixel Value and SUV Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `Units` | `"BQML"` | PET pixel-value units (e.g., BQML, GML, CM2ML, CNTS). |
| `SUVType` | `"BW"` | SUV normalization type (e.g., BW). |
| `RescaleSlope` | `"1.0"` | Stored-pixel rescale slope (DS). |
| `RescaleIntercept` | `"0.0"` | Stored-pixel rescale intercept (DS). |
| `PhilipsSUVScaleFactor` | `None` | Philips vendor-private SUV scaling factor; not a public DICOM keyword. |
| `PhilipsActivityConcentrationScaleFactor` | `None` | Philips vendor-private activity concentration scaling factor; not a public DICOM keyword. |

### 5. Decay and Correction Factors

| Parameter | Default Value | Description |
|---|---|---|
| `DecayCorrection` | `"START"` | Decay correction reference (START, ADMIN, NONE). |
| `DecayFactor` | `"1.2"` | Decay factor actually applied. |
| `DoseCalibrationFactor` | `"1.0"` | Dose calibration factor actually applied. |
| `SliceSensitivityFactor` | `"1.0"` | Slice sensitivity correction factor actually applied. |
| `ScatterFractionFactor` | `"0.25"` | Scatter fraction correction factor actually applied. |
| `DeadTimeFactor` | `"1.05"` | Detector dead-time correction factor actually applied. |

### 6. Count Statistics and Correction Methods

| Parameter | Default Value | Description |
|---|---|---|
| `PrimaryPromptsCountsAccumulated` | `"10000000"` | Accumulated primary prompt counts. |
| `SecondaryCountsAccumulated` | `"1500000"` | Accumulated secondary counts. |
| `CorrectedImage` | `["ATTN", "SCAT", "DECY", "RAN"]` | Applied image correction codes (DICOM multi-valued CS). |
| `RandomsCorrectionMethod` | `"DLYD"` | Randoms correction method (e.g., DLYD). |
| `AttenuationCorrectionMethod` | `"CT-based attenuation correction"` | Attenuation correction method. |
| `ScatterCorrectionMethod` | `"Model-based scatter correction"` | Scatter correction method. |
| `ReconstructionMethod` | `"OSEM"` | Image reconstruction method. |

### 7. Image Geometry and Spatial Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `Rows` | `256` | Number of image rows. Must match the NumPy array dimensions. |
| `Columns` | `256` | Number of image columns. Must match the NumPy array dimensions. |
| `PixelSpacing` | `[4.0, 4.0]` | Pixel spacing in row and column directions (mm). |
| `SliceThickness` | `"3.0"` | Slice thickness (mm). |
| `SpacingBetweenSlices` | `"3.0"` | Distance between adjacent slices (mm). |
| `ImagePositionPatient` | `[0.0, 0.0, 0.0]` | Image position in patient coordinates (x, y, z) in mm. Frame/slice specific. |
| `ImageOrientationPatient` | `[1.0, 0.0, 0.0, 0.0, 1.0, 0.0]` | Row and column direction cosines (6 values). |

### 8. PET Image and Reconstruction Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `SeriesType` | `["STATIC", "IMAGE"]` | PET series type (DICOM multi-valued CS). |
| `CountsSource` | `"EMISSION"` | PET counts source (EMISSION or TRANSMISSION). |
| `ReconstructionDiameter` | `"600.0"` | Reconstruction diameter (mm). |
| `PETFrameCorrectionFactorsSequence` | `None` | Enhanced PET frame correction factors (DICOM SQ). Requires a verified sequence structure. |

### 9. Enhanced PET Correction Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `DecayCorrectionDateTime` | `"20261010100000"` | Enhanced PET decay correction reference date and time (DT). |
| `DecayCorrected` | `"YES"` | Indicates whether decay correction has been applied (YES/NO). |
| `AttenuationCorrected` | `"YES"` | Indicates whether attenuation correction has been applied (YES/NO). |
| `ScatterCorrected` | `"YES"` | Indicates whether scatter correction has been applied (YES/NO). |
| `RandomsCorrected` | `"YES"` | Indicates whether randoms correction has been applied (YES/NO). |

### 10. Application-Specific Parameters

| Parameter | Default Value | Description |
|---|---|---|
| `erode_voxels` | `"0"` | Legacy application-specific setting. Not a DICOM attribute. |

**Note:** DICOM inputs automatically provide metadata through their headers. NumPy inputs require a corresponding DICOM metadata dictionary.
`parameter_estimation` controls metadata replacement:

| Option | Behavior |
|---|---|
| `"OFF"` | Does not fill missing parameters from the configured notebook defaults. |
| `"ON"` |  Fills eligible missing metadata fields using configured defaults; existing values are not generally replaced. |

The notebook has configurable values for patient weight, age, height, sex; administered dose, half-life and radiopharmaceutical timing; acquisition and series times; PET units; SUV type; decay correction; rescale slope and intercept; image geometry; and other fields. These settings are **not additional keyword arguments** of `radiuma_suv_from_input`.

The source implements unit conversion paths involving `BQML`, `GML`, `CM2ML`, and `CNTS`. Successful processing depends on the necessary metadata and calibration factors. The `BQML` converter handles `DecayCorrection` values `ADMIN`, `START`, and `NONE` with different reference-time logic. The source also includes body-composition helper functions used for certain `GML` SUV normalization variants.


## 📥 Installation

Dependencies imported by the notebook are `numpy`, `pydicom`, and `SimpleITK`; other referenced Python modules are standard-library modules. In the original notebook the installation line is `%pip install numpy pydicom SimpleITK`; for a published library, declare these in `pyproject.toml` instead.

### 🌐 GitHub Installation

https://git.talkfluent.ir/admin/radiuma_suv/src/branch/main

```bash
git clone https://github.com/YOUR_USERNAME/radiuma_suv.git
cd radiuma_suv
python -m pip install -e .
```

### macOS/Linux Installation

```bash
python3 -m venv .venv
source .venv/bin/activate
python -m pip install --upgrade pip
python -m pip install -e .
```

### Windows Setup

In PowerShell inside the project directory:

```powershell
python -m venv .venv
.venv\Scripts\Activate.ps1
python -m pip install --upgrade pip
python -m pip install -e .
```

### 💻 Python Script - Command Line Interface (CLI)

The notebook contains an example `if __name__ == "__main__":` block but **does not implement an argument-parsing CLI or a `radiuma_suv` terminal command**. Create a short Python script when you want command-line execution:

```python
# convert_pet.py
from radiuma_suv import radiuma_suv_from_input
path, headers = radiuma_suv_from_input("pet_scan.dcm", parameter_estimation="OFF")
print(path)
```

```bash
python convert_pet.py
```

### 📦 Library Installation via pip

```bash
python -m pip install radiuma_suv
```

This will install the intended project **only after it is actually published** under that name on PyPI.

## 📂 Data Structure Requirements

The notebook processes PET DICOM input **without masks**. Examples of appropriate layouts:

**Single PET image:**

```text
PET/
└── scan.dcm
```

**Conventional PET image series:**

```text
PET_Series/
├── slice_001.dcm
├── slice_002.dcm
└── slice_003.dcm
```

**Hierarchical directory:**

```text
Patients/
├── patient_001/
│   └── PET/
│       ├── slice_001.dcm
│       └── slice_002.dcm
└── patient_002/
    └── PET/
        └── enhanced_pet.dcm
```

The source searches directories recursively, reads DICOM headers, selects `Modality=PT`, and groups series by their `SeriesInstanceUID` and folder. A DICOM series spanning different source folders is rejected by the writer. The corresponding output folders preserve relative structure with `_processed` naming.

**Output must not be inside the source directory.** Existing destinations are not overwritten. Non-DICOM files may be skipped during directory discovery, but `.nii`, `.nii.gz`, `.nrrd`, and `.nhdr` are not valid radiuma_suv PET inputs. For NumPy, pass an in-memory `ndarray` and DICOM metadata; a `.npy` *path* is not accepted by `radiuma_suv_from_input`.

## 📋 Synthesize Missing Inputs

### Public function parameters

| Parameter | Type | Default | Description |
|---|---|---|---|
| `input_array` | `numpy.ndarray` | Required | PET array passed to `radiuma_suv`. |
| `input_metadata` | `dict` | Required | Corresponding PET DICOM metadata dictionary. |
| `image_input` | `numpy.ndarray`, string, path-like | Required | NumPy array, PET DICOM file, or PET DICOM directory. |
| `parameter_estimation` | `str` | `"OFF"` | `"ON"` or `"OFF"` only. |
| `output_path` | string / path-like / `None` | `None` | Destination for DICOM outputs; not valid with NumPy input. |
| `pet_metadata` | `dict` or `None` | `None` | `RadiumaSUVLoader` metadata for a NumPy input. |

### Selected configured DICOM fields

These are **example literal settings present in the notebook**, not a universal dataset or recommended patient parameters.

| Metadata field | Notebook setting | Meaning |
|---|---|---|
| `PatientWeight` | `"75.5"` | Patient weight, kg |
| `PatientAge` | `"045Y"` | Age in DICOM AS format |
| `PatientSize` | `"1.75"` | Height, m |
| `PatientSex` | `"M"` | DICOM sex code |
| `RadionuclideTotalDose` | `"370000000"` | Radionuclide activity; representation-specific unit handling must be verified |
| `RadionuclideHalfLife` | `"6586.2"` | Half-life, s |
| `RadiopharmaceuticalStartDateTime` | `"20261010093015"` | Radiopharmaceutical administration start |
| `ActualFrameDuration` | `"180000"` | Frame duration, ms |
| `FrameReferenceTime` | `"90000"` | Frame reference time, ms |
| `AcquisitionDate` | `"20261010"` | DICOM DA |
| `AcquisitionTime` | `"100000"` | DICOM TM |
| `Units` | `"BQML"` | PET units | BQML, GML, CM2ML, CNTS
| `DecayCorrection` | `"START"` | Decay reference |
| `RescaleSlope` | `"1.0"` | Pixel calibration slope |
| `RescaleIntercept` | `"0.0"` | Pixel calibration intercept |
| `Rows`, `Columns` | `256`, `256` | Example image size |
| `PixelSpacing` | `[4.0, 4.0]` | Row/column spacing, mm |
| `SliceThickness` | `"3.0"` | Slice thickness, mm |
| `ImagePositionPatient` | `[0.0, 0.0, 0.0]` | Image coordinates, mm |
| `ImageOrientationPatient` | `[1, 0, 0, 0, 1, 0]` | Orientation cosines |

The source defines many additional correction, geometry, timing, and vendor-related fields. Consult the notebook's **User Controlled Parameters** section for the complete set. These values should not be inferred or substituted without acquisition-specific evidence.

## 📊 Parameter Compatibility

| Feature / argument | NumPy + metadata | Single PET DICOM | DICOM directory |
|---|---:|---:|---:|
| `parameter_estimation` | ✓ | ✓ | ✓ |
| `output_path` | Not allowed | ✓ | ✓ |
| Floating-point array return | ✓ | No | No |
| Derived DICOM output | No | ✓ | ✓ |
| Independent series grouping | No | No | ✓ |


## 📚 API Reference

### `radiuma_suv(input_array, input_metadata, parameter_estimation="OFF")`

Converts an in-memory PET NumPy array to SUVbw. Returns `(suv_array, output_metadata)`.

### `radiuma_suv(input_array, input_metadata, parameter_estimation="ON")` 

Converts an in-memory PET NumPy array to SUVbw, it replace missed parameters in input image DICOM header with default vlues defined in code. Returns `(suv_array, output_metadata)`.

### `radiuma_suv_from_input(image_input, parameter_estimation="OFF", output_path=None)`

Detects input representation and returns a matching result: a NumPy array or a new DICOM output file/folder path, plus corresponding metadata. DICOM source objects are not deliberately overwritten.

### `radiuma_suv_from_input(image_input, parameter_estimation="ON", output_path=None)`
Detects input representation and returns a matching result: a new DICOM output file/folder path, it replace missed parameters in input image DICOM header with default vlues defined in code. DICOM source objects are not deliberately overwritten.


## 📊 Output Structure

| Input | First return value | Second return value |
|---|---|---|
| NumPy array | Floating-point SUVbw NumPy array | Metadata dictionary |
| Single PET DICOM file | New DICOM file path | Output header dictionary |
| PET DICOM folder, one series | Output directory path | List of header dictionaries |
| Folder, multiple series | Output root directory path | Nested header lists |

**DICOM representation:** The source encodes SUVbw into calibrated **signed 16-bit pixels**. For conventional PET, the output `RescaleSlope` is needed to recover actual SUVbw. For Enhanced PET, use its real-world value mapping. The writer checks the saved file's pixel shape and reconstruction against calculated values within quantization tolerance. This is not an independent reference SUV validation.


## 📁 Supported File Formats

| Format | Supported | Notes |
|---|---|---|
| Conventional PET DICOM `.dcm` | Yes | Single frame |
| Enhanced PET DICOM `.dcm` | Yes | Multi-frame Enhanced PET SOP class |
| Extensionless DICOM in a folder | Detected if readable | Must identify as PET (`Modality=PT`) |
| PET DICOM directory | Yes | Recursive series grouping |
| `.npy` path | No | Load with `np.load()` and pass array |

## 🎯 Library Examples

### Example 1: Single DICOM

```python
from radiuma_suv import radiuma_suv_from_input
result, meta = radiuma_suv_from_input("pet.dcm", parameter_estimation="OFF")

print(result)
```
```python
from radiuma_suv import radiuma_suv_from_input
result, meta = radiuma_suv_from_input("pet.dcm", parameter_estimation="ON")

PatientWeight = "75.5"  # Patient weight (kg); patient-specific  # Changing is not Recommended
PatientAge = "045Y"  # Age (DICOM AS format); patient-specific
PatientSize = "1.75"  # Height (m); patient-specific  # Changing is not Recommended
PatientSex = "M"  # DICOM M/F/O; patient-specific  # Changing is not Recommended
RadionuclideTotalDose = "370000000"  # Administered dose; conventional PET Bq, Enhanced PET MBq; must be verified against source IOD  # Changing is not Recommended
RadionuclideHalfLife = "6586.2"  # Radionuclide half-life (s); must match actual tracer  # Changing is not Recommended
RadiopharmaceuticalStartTime = "093015"  # Administration start time (TM, HHMMSS); deprecated, prefer full DateTime  # Changing is not Recommended
RadiopharmaceuticalStartDateTime = "20261010093015"  # Administration start datetime (DT)  # Changing is not Recommended
RadionuclidePositronFraction = "0.967"  # Radionuclide positron fraction [0,1]
RadiopharmaceuticalSpecificActivity = "1000000000"  # Specific activity in Bq/micromole
RadiopharmaceuticalVolume = "5.0"  # Administered radiopharmaceutical volume (cm^3)
RadiopharmaceuticalStopTime = "093115"  # Administration stop time (TM); deprecated, prefer full DateTime
RadiopharmaceuticalStopDateTime = None  # Standard DICOM DT (0018,1079); use actual recorded stop datetime
ActualFrameDuration = "180000"  # Acquisition-frame duration (ms)  # Changing is not Recommended
FrameReferenceTime = "90000"  # Frame reference time (ms)  # Changing is not Recommended
AcquisitionDate = "20261010"  # Acquisition date (DA YYYYMMDD)  # Changing is not Recommended
AcquisitionTime = "100000"  # Acquisition time (TM HHMMSS)  # Changing is not Recommended
SeriesDate = "20261010"  # Series date (DA YYYYMMDD)  # Changing is not Recommended
SeriesTime = "095500"  # Series time (TM HHMMSS)  # Changing is not Recommended
FrameTime = "1000"  # Frame time (ms); conditional on acquisition type
TriggerTime = "0"  # Trigger time (ms); conditional on acquisition type
NominalInterval = "800"  # Nominal interval (ms); conditional on gated acquisition
IntervalsAcquired = "1000"  # Count of intervals acquired; conditional
IntervalsRejected = "10"  # Count of intervals rejected; conditional
NumberOfTimeSlices = "1"  # Number of time slices; conditional
NumberOfTimeSlots = "1"  # Number of time slots; conditional
Units = "BQML"  # PET pixel-value units (e.g. BQML, GML, CM2ML, CNTS)  # Changing is not Recommended
SUVType = "BW"  # SUV normalization type (e.g. BW)  # Changing is not Recommended
RescaleSlope = "1.0"  # Stored-pixel rescale slope (DS)  # Changing is not Recommended
RescaleIntercept = "0.0"  # Stored-pixel rescale intercept (DS)  # Changing is not Recommended
PhilipsSUVScaleFactor = None  # Philips vendor-private factor; not a public DICOM keyword  # Changing is not Recommended
PhilipsActivityConcentrationScaleFactor = None  # Philips vendor-private activity scaling; not a public DICOM keyword  # Changing is not Recommended
DecayCorrection = "START"  # Decay correction reference (START, ADMIN, NONE)  # Changing is not Recommended
DecayFactor = "1.2"  # Decay factor actually applied
DoseCalibrationFactor = "1.0"  # Dose calibration factor actually applied
SliceSensitivityFactor = "1.0"  # Slice sensitivity correction factor actually applied
ScatterFractionFactor = "0.25"  # Scatter fraction correction factor actually applied
DeadTimeFactor = "1.05"  # Detector dead-time factor actually applied
PrimaryPromptsCountsAccumulated = "10000000"  # Primary accumulated prompt counts
SecondaryCountsAccumulated = "1500000"  # Secondary accumulated counts
CorrectedImage = ["ATTN", "SCAT", "DECY", "RAN"]  # Applied correction codes (DICOM multi-valued CS)
RandomsCorrectionMethod = "DLYD"  # Randoms correction method (e.g. DLYD)
AttenuationCorrectionMethod = "CT-based attenuation correction"  # Attenuation correction method (descriptive text)
ScatterCorrectionMethod = "Model-based scatter correction"  # Scatter correction method (descriptive text)
ReconstructionMethod = "OSEM"  # Reconstruction method (descriptive text)
Rows = 256  # Image rows (US integer); must match NumPy array
Columns = 256  # Image columns (US integer); must match NumPy array
PixelSpacing = [4.0, 4.0]  # Row/column spacing [mm, mm]
SliceThickness = "3.0"  # Slice thickness (mm)
SpacingBetweenSlices = "3.0"  # Slice spacing (mm)
ImagePositionPatient = [0.0, 0.0, 0.0]  # Image position [x,y,z] mm; frame/slice specific
ImageOrientationPatient = [1.0, 0.0, 0.0, 0.0, 1.0, 0.0]  # Row/column direction cosines [6 values]
SeriesType = ["STATIC", "IMAGE"]  # PET series type (multi-valued CS)
CountsSource = "EMISSION"  # PET counts source (EMISSION or TRANSMISSION)
ReconstructionDiameter = "600.0"  # Reconstruction diameter (mm)
PETFrameCorrectionFactorsSequence = None  # Enhanced PET frame corrections (DICOM SQ); supply verified structure
DecayCorrectionDateTime = "20261010100000"  # Enhanced PET decay correction reference (DT)  # Changing is not Recommended
DecayCorrected = "YES"  # Enhanced PET decay correction flag YES/NO  # Changing is not Recommended
AttenuationCorrected = "YES"  # Enhanced PET attenuation correction flag YES/NO
ScatterCorrected = "YES"  # Enhanced PET scatter correction flag YES/NO
RandomsCorrected = "YES"  # Enhanced PET randoms correction flag YES/NO
erode_voxels = "0"  # Legacy application-only setting; NOT a DICOM attribute
print(result)
```

### Example 2: Multiple PET folders

```python
from radiuma_suv import radiuma_suv_from_input
out, headers = radiuma_suv_from_input(
    "PET_Input", parameter_estimation="OFF", output_path="SUV_Output"
)
```
```python
from radiuma_suv import radiuma_suv_from_input
out, headers = radiuma_suv_from_input(
    "PET_Input", parameter_estimation="ON", output_path="SUV_Output"
)
PatientWeight = "75.5"  # Patient weight (kg); patient-specific  # Changing is not Recommended
PatientAge = "045Y"  # Age (DICOM AS format); patient-specific
PatientSize = "1.75"  # Height (m); patient-specific  # Changing is not Recommended
PatientSex = "M"  # DICOM M/F/O; patient-specific  # Changing is not Recommended
RadionuclideTotalDose = "370000000"  # Administered dose; conventional PET Bq, Enhanced PET MBq; must be verified against source IOD  # Changing is not Recommended
RadionuclideHalfLife = "6586.2"  # Radionuclide half-life (s); must match actual tracer  # Changing is not Recommended
RadiopharmaceuticalStartTime = "093015"  # Administration start time (TM, HHMMSS); deprecated, prefer full DateTime  # Changing is not Recommended
RadiopharmaceuticalStartDateTime = "20261010093015"  # Administration start datetime (DT)  # Changing is not Recommended
RadionuclidePositronFraction = "0.967"  # Radionuclide positron fraction [0,1]
RadiopharmaceuticalSpecificActivity = "1000000000"  # Specific activity in Bq/micromole
RadiopharmaceuticalVolume = "5.0"  # Administered radiopharmaceutical volume (cm^3)
RadiopharmaceuticalStopTime = "093115"  # Administration stop time (TM); deprecated, prefer full DateTime
RadiopharmaceuticalStopDateTime = None  # Standard DICOM DT (0018,1079); use actual recorded stop datetime
ActualFrameDuration = "180000"  # Acquisition-frame duration (ms)  # Changing is not Recommended
FrameReferenceTime = "90000"  # Frame reference time (ms)  # Changing is not Recommended
AcquisitionDate = "20261010"  # Acquisition date (DA YYYYMMDD)  # Changing is not Recommended
AcquisitionTime = "100000"  # Acquisition time (TM HHMMSS)  # Changing is not Recommended
SeriesDate = "20261010"  # Series date (DA YYYYMMDD)  # Changing is not Recommended
SeriesTime = "095500"  # Series time (TM HHMMSS)  # Changing is not Recommended
FrameTime = "1000"  # Frame time (ms); conditional on acquisition type
TriggerTime = "0"  # Trigger time (ms); conditional on acquisition type
NominalInterval = "800"  # Nominal interval (ms); conditional on gated acquisition
IntervalsAcquired = "1000"  # Count of intervals acquired; conditional
IntervalsRejected = "10"  # Count of intervals rejected; conditional
NumberOfTimeSlices = "1"  # Number of time slices; conditional
NumberOfTimeSlots = "1"  # Number of time slots; conditional
Units = "BQML"  # PET pixel-value units (e.g. BQML, GML, CM2ML, CNTS)  # Changing is not Recommended
SUVType = "BW"  # SUV normalization type (e.g. BW)  # Changing is not Recommended
RescaleSlope = "1.0"  # Stored-pixel rescale slope (DS)  # Changing is not Recommended
RescaleIntercept = "0.0"  # Stored-pixel rescale intercept (DS)  # Changing is not Recommended
PhilipsSUVScaleFactor = None  # Philips vendor-private factor; not a public DICOM keyword  # Changing is not Recommended
PhilipsActivityConcentrationScaleFactor = None  # Philips vendor-private activity scaling; not a public DICOM keyword  # Changing is not Recommended
DecayCorrection = "START"  # Decay correction reference (START, ADMIN, NONE)  # Changing is not Recommended
DecayFactor = "1.2"  # Decay factor actually applied
DoseCalibrationFactor = "1.0"  # Dose calibration factor actually applied
SliceSensitivityFactor = "1.0"  # Slice sensitivity correction factor actually applied
ScatterFractionFactor = "0.25"  # Scatter fraction correction factor actually applied
DeadTimeFactor = "1.05"  # Detector dead-time factor actually applied
PrimaryPromptsCountsAccumulated = "10000000"  # Primary accumulated prompt counts
SecondaryCountsAccumulated = "1500000"  # Secondary accumulated counts
CorrectedImage = ["ATTN", "SCAT", "DECY", "RAN"]  # Applied correction codes (DICOM multi-valued CS)
RandomsCorrectionMethod = "DLYD"  # Randoms correction method (e.g. DLYD)
AttenuationCorrectionMethod = "CT-based attenuation correction"  # Attenuation correction method (descriptive text)
ScatterCorrectionMethod = "Model-based scatter correction"  # Scatter correction method (descriptive text)
ReconstructionMethod = "OSEM"  # Reconstruction method (descriptive text)
Rows = 256  # Image rows (US integer); must match NumPy array
Columns = 256  # Image columns (US integer); must match NumPy array
PixelSpacing = [4.0, 4.0]  # Row/column spacing [mm, mm]
SliceThickness = "3.0"  # Slice thickness (mm)
SpacingBetweenSlices = "3.0"  # Slice spacing (mm)
ImagePositionPatient = [0.0, 0.0, 0.0]  # Image position [x,y,z] mm; frame/slice specific
ImageOrientationPatient = [1.0, 0.0, 0.0, 0.0, 1.0, 0.0]  # Row/column direction cosines [6 values]
SeriesType = ["STATIC", "IMAGE"]  # PET series type (multi-valued CS)
CountsSource = "EMISSION"  # PET counts source (EMISSION or TRANSMISSION)
ReconstructionDiameter = "600.0"  # Reconstruction diameter (mm)
PETFrameCorrectionFactorsSequence = None  # Enhanced PET frame corrections (DICOM SQ); supply verified structure
DecayCorrectionDateTime = "20261010100000"  # Enhanced PET decay correction reference (DT)  # Changing is not Recommended
DecayCorrected = "YES"  # Enhanced PET decay correction flag YES/NO  # Changing is not Recommended
AttenuationCorrected = "YES"  # Enhanced PET attenuation correction flag YES/NO
ScatterCorrected = "YES"  # Enhanced PET scatter correction flag YES/NO
RandomsCorrected = "YES"  # Enhanced PET randoms correction flag YES/NO
erode_voxels = "0"  # Legacy application-only setting; NOT a DICOM attribute

```

### Example 3: NumPy data

```python
import numpy as np
from radiuma_suv import radiuma_suv
pixels = np.load("pet_pixels.npy")
# Load the genuine DICOM metadata for the same scan.
suv, meta = radiuma_suv(pixels, matching_pet_dicom_metadata, "OFF")
```
```python
import numpy as np
from radiuma_suv import radiuma_suv
pixels = np.load("pet_pixels.npy")
# Load the genuine DICOM metadata for the same scan.
suv, meta = radiuma_suv(pixels, matching_pet_dicom_metadata, "ON")
```
## ⚡ Performance Tips

1. Use the folder interface when processing multiple PET DICOM series.
2. Keep output outside the input directory and ensure the output path does not exist.
3. Avoid making unnecessary copies of large arrays when working with NumPy.
4. Use real acquisition-specific metadata for correct dose and decay calculations.
5. Validate numerical values after conversion and DICOM quantization.
6. The notebook contains no benchmarking results, so no speed claims are made here.



## ❓ Troubleshooting

| Message / problem | Recommended check |
|---|---|
| `ModuleNotFoundError: No module named 'radiuma_suv'` | Confirm the package was created, installed, and imported from the active Python environment. |
| `parameter_estimation must be "ON" or "OFF"` | Use the exact supported values. |
| `Input must be PET DICOM (Modality=PT)` | Confirm the file really contains PET DICOM. |
| `Non-Enhanced multi-frame PET is unsupported` | Input format is outside the implemented multi-frame path. |
| `No PET DICOM series found` | Verify DICOM readability, modality, and folder contents. |
| `Output directory must not be nested within input folder` | Choose an independent output directory. |
| `Refusing to overwrite existing output` | Choose another destination. |
| Missing activity, weight, half-life, or timing | Review source metadata; do not blindly apply configured defaults. |
| Unexpected SUVbw values | Recheck units, calibration, corrected dose, decay time, and actual acquisition data. |

### ❓ Get Help

- **Documentation:** Refer to this README for installation, configuration, supported formats, and usage examples.
- **Execution:** See the **Script Execution** section for standalone and embedded usage.
- **Troubleshooting:** Check the **Troubleshooting** section for common errors and solutions.
- **Issues and Bug Reports:** [GitHub Issues](https://github.com/radiuma-com/radiuma_suv/issues).
- **Technical Support:** Contact the development team using the details in the **Contact** or **Maintenance** section. 

## 🕒 Version History


```text
v1.0.1 
- Conventional PET DICOM to SUVbw
- Enhanced multi-frame PET to SUVbw
- NumPy input and metadata output
- Recursive DICOM series processing
```

## 📬 Contact

radiuma_suv is available **free of charge**.
For access, questions, or feedback:

**Dr. Mohammad R. Salmanpour (Team Lead)**  
📧[msalman@bccrc.ca](mailto:msalman@bccrc.ca) | [m.salmanpoor66@gmail.com](mailto:m.salmanpoor66@gmail.com), [m.salmanpour@ubc.ca](mailto:m.salmanpour@ubc.ca)

---
## 🛠️ Maintenance

For technical support and maintenance inquiries, please contact:

**Dr. Mohammad R. Salmanpour (Team Lead)**  
 msalman@bccrc.ca – m.salmanpoor66@gmail.com – m.salmanpour@ubc.ca

**Ramin Afrah (Maintainer)**  
 afrah.ramin@gmail.com
## 👥 Authors

- **Dr. Mohammad R. Salmanpour (Team Lead, Fund Provider, Evaluator, Medical Imaging Expert, Backend Development, Code Refactoring, Debugging, Library Management, IBSI Standardization, and Activation of the radiuma_suv library)** – [msalman@bccrc.ca](mailto:msalman@bccrc.ca), [m.salmanpoor66@gmail.com](mailto:m.salmanpoor66@gmail.com), [m.salmanpour@ubc.ca](mailto:m.salmanpour@ubc.ca)
- **Ramin Afrah (Development, Code Refactoring, Debugging, and Library Management)** - [afrah.ramin@gmail.com](mailto:afrah.ramin@gmail.com)
- **Dr. Mehrdad Oveisi (Evaluator and Software Engineer)** 
- **Dr. Arman Rahmim (Fund Provider, Medical Imaging Expert, Evaluator, and Advisor)** 

## 📚 Citation


```bibtex
Coming soon
```

## 📜 License

This open-source software is released under the **MIT License**, which grants permission to use, modify, and distribute it for any purpose, including research or commercial use, without requiring modified versions to be shared as open source. See the [LICENSE](LICENSE) file for details.

## Support


- **Issues**: [GitHub Issues](https://github.com/radiuma-com/radiuma_suv/issues)
- **Documentation**: This README and the included guides
- **Examples**: See `examples/basic_usage.py`


## Acknowledgment

- [🔬 **Qu**antitative **R**adiomolecular **I**maging and **T**herapy (Qurit) Lab, University of British Columbia, Vancouver, BC, Canada](https://www.qurit.ca)  
- [🏥 BC Cancer Research Institute, Department of Basic and Translational Research, Vancouver, BC, Canada](https://www.bccrc.ca/)  
- [💻 **Vir**tual **Collab**oration (VirCollab) Group, Vancouver, BC, Canada](https://vircollab.com/#/) 