Metadata-Version: 2.4
Name: citadel-simulator
Version: 1.0.6
Summary: CITADEL Critical Infrastructure Simulator
Author: CITADEL Project
License-Expression: GPL-3.0-or-later
Project-URL: Homepage, https://github.com/argonne-citadel/citadel-simulator
Project-URL: Repository, https://github.com/argonne-citadel/citadel-simulator.git
Keywords: simulator,cybersecurity,electrical-grid,critical-infrastructure
Classifier: Development Status :: 3 - Alpha
Classifier: Intended Audience :: Developers
Classifier: Intended Audience :: Science/Research
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.12
Classifier: Topic :: Security
Classifier: Topic :: Scientific/Engineering
Requires-Python: >=3.12
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: stix2~=3.0.1
Requires-Dist: grid-stix~=2.6
Requires-Dist: flask~=3.1.0
Requires-Dist: pandapower~=3.2.0
Requires-Dist: pydantic~=2.12.0
Requires-Dist: pymodbus~=3.11.0
Requires-Dist: python-dotenv~=1.2.0
Requires-Dist: structlog~=25.5.0
Requires-Dist: numba~=0.62.0
Provides-Extra: dev
Requires-Dist: bandit>=1.8; extra == "dev"
Requires-Dist: black>=25.1; extra == "dev"
Requires-Dist: mypy>=1.17; extra == "dev"
Requires-Dist: pytest>=8.4; extra == "dev"
Requires-Dist: pytest-asyncio>=1.0; extra == "dev"
Requires-Dist: pytest-cov>=6.1; extra == "dev"
Requires-Dist: pytest-mock>=3.14; extra == "dev"
Dynamic: license-file

# CITADEL Grid Simulator

A pandapower-based electrical grid simulation system with DERs (Distributed Energy Resources) for cybersecurity and zero-trust policy research. The simulator acts as SCADA substations/RTUs communicating via DNP3 and Modbus protocols.

## Overview

The CITADEL Grid Simulator provides realistic power grid simulation capabilities for research and testing:

- **Modern Grid Model**: Dickert LV distribution network with DER support
- **Real-time Simulation**: 1-second timestep power flow calculations
- **SCADA Protocols**: DNP3 outstation and Modbus server interfaces
- **Time-Series Data**: Realistic load, solar PV, and wind generation profiles
- **Zero-Trust Ready**: Control points for policy enforcement on breakers, loads, and DERs
- **Thread-Safe**: Concurrent operation with command queue and state callbacks

## Installation

```bash
# Using micromamba (recommended)
micromamba env create -f environment.yml
micromamba activate grid-simulator

# Or using conda
conda env create -f environment.yml
conda activate grid-simulator
```

## Configuration

```bash
# Copy example config
cp src/settingslocal.py.example src/settingslocal.py

# Edit configuration as needed
nano src/settingslocal.py
```

## Running the Simulator

```bash
# Using Makefile
make run

# Or directly
cd src && python -m main

# Or using the installed command
citadel-simulator
```

## Grid Models

The simulator provides an extensible framework for power grid modeling. The default implementation uses the Dickert LV distribution network model, but the architecture supports custom grid models.

### Default Model: Dickert LV Network

The included Dickert LV model is specifically designed for DER research and serves as a reference implementation:

- **DER-focused**: Designed for distribution-level DER integration studies
- **Modern architecture**: Reflects current grids with high DER penetration
- **Zero-trust suitable**: Smaller scale ideal for cyber/control experimentation
- **Realistic topology**: Includes residential/commercial loads, solar PV, storage
- **Manageable scale**: Rapid iteration for policy enforcement scenarios

**Network Classes**:
- **Class 1**: Smallest network (default)
- **Class 2-5**: Increasing size and complexity

### Custom Grid Models

The simulator architecture is designed to be model-agnostic. You can implement custom grid models by:

1. Creating a new model class in `src/models/`
2. Implementing the required pandapower network structure
3. Registering the model in the configuration

See `src/models/dickert_lv.py` for a reference implementation.

### Reference

```
@inproceedings{dickert2013,
  author = {Dickert, Jörg and Domagk, Max and Schegner, Peter},
  year = {2013},
  month = {06},
  title = {Benchmark Low Voltage Distribution Networks Based on Cluster Analysis of Actual Grid Properties},
  doi = {10.1109/PTC.2013.6652250}
}
```

## SCADA Protocols

### DNP3 Outstation

**Port**: 20000 (configurable)

**Point Mapping**:
- Analog Inputs 0-N: Bus voltages (per unit)
- Analog Inputs 100+: Line power flows (MW)
- Analog Inputs 200+: DER generation (MW)
- Binary Inputs 0-N: Breaker status (open/closed)
- Binary Outputs 0-N: Breaker controls

**Features**:
- Integrity polls
- Event reporting
- Control operations
- Quality flags
- Timestamps

### Modbus Server

**Port**: 502 (configurable)

**Register Mapping**:
- Holding Registers 0-999: Bus voltages (scaled)
- Holding Registers 1000-1999: Line flows (scaled)
- Holding Registers 2000-2999: DER generation (scaled)
- Coils 0-999: Breaker status
- Coils 1000-1999: Breaker controls

**Features**:
- Function codes: 1, 2, 3, 4, 5, 6, 15, 16
- Exception handling
- Multiple client support

## SCADA Commands

The simulator supports the following control commands:

- `OPEN_BREAKER` - Open a line breaker
- `CLOSE_BREAKER` - Close a line breaker
- `SET_DER_SETPOINT` - Adjust DER power output
- `ADJUST_LOAD` - Modify load demand
- `SET_STORAGE_POWER` - Control energy storage (charge/discharge)

## Configuration

### Environment Variables

```bash
# Simulation
SIMULATION_TIMESTEP=1.0          # seconds
NETWORK_CLASS=1                  # Dickert LV network class (1-5)
NUM_TRANSFORMERS=1               # Number of transformers (1-2)

# DNP3
DNP3_ENABLED=true
DNP3_PORT=20000
DNP3_LOCAL_ADDRESS=1
DNP3_REMOTE_ADDRESS=10

# Modbus
MODBUS_ENABLED=true
MODBUS_PORT=502
MODBUS_UNIT_ID=1

# Logging
LOG_LEVEL=INFO
LOG_FILE=grid_simulator.log
```

### Settings File

See `src/settingslocal.py.example` for all configuration options.

## Time-Series Data Generation

The simulator includes comprehensive time-series generators for realistic load and generation profiles.

### Load Profiles

**Residential**:
- Morning peak: 6-9 AM
- Evening peak: 5-10 PM
- Overnight minimum: 11 PM - 5 AM
- Seasonal variations (summer AC, winter heating)
- Weekday/weekend differences
- Stochastic noise (15%)

**Commercial**:
- Office: 8 AM - 6 PM weekdays
- Retail: 9 AM - 9 PM daily
- Industrial: 24/7 operation
- Stochastic noise (10%)

### Solar PV Profiles

- Cosine irradiance curve (sunrise to sunset)
- Seasonal sun angle variations
- Cloud effects: clear, partly cloudy, cloudy
- Inverter efficiency (96% default)
- Day-to-day variability

### Wind Profiles

- Power curve: cut-in 3 m/s, rated 12 m/s, cut-out 25 m/s
- AR(1) process for temporal correlation
- Cubic power relationship
- Stochastic variations

### Example Usage

```python
from timeseries import LoadProfileGenerator, SolarProfileGenerator

# Generate load profiles
load_gen = LoadProfileGenerator(random_seed=42)
loads = load_gen.generate_multiple_loads(
    num_residential=5,
    num_commercial=2,
    num_days=7,
    season='summer'
)

# Generate solar profiles
solar_gen = SolarProfileGenerator(random_seed=42)
solar = solar_gen.generate_with_variability(
    num_days=7,
    rated_capacity_kw=10.0,
    season='summer'
)

# Convert to pandapower format
load_pp = load_gen.to_pandapower_format(loads, load_indices)
solar_pp = solar_gen.to_pandapower_format(solar, sgen_indices)
```

## Development

### Makefile Commands

```bash
make help      # Show available commands
make install   # Create conda environment
make test      # Run tests
make run       # Run simulator
make clean     # Remove generated files
make lint      # Run linting
make format    # Format code
```

### Testing

```bash
# Run all tests
make test

# Run specific test file
python -m pytest src/tests/test_basic.py -v

# Run with coverage
python -m pytest --cov=src src/tests/
```

### SCADA Client Testing

```bash
# Test with Modbus client
mbpoll -a 1 -r 0 -c 10 localhost

# Test with DNP3 client
# (Use dnp3demo or similar DNP3 master tool)
```

## Performance

- **Timestep**: 1 second (configurable)
- **State history**: 3600 steps (1 hour at 1s timestep)
- **Protocol updates**: On every timestep
- **Typical CPU**: <5% for Class 1 network
- **Memory**: ~100MB for Class 1 network

## Troubleshooting

### Common Issues

**Power flow doesn't converge**:
- Check load/generation balance
- Verify network connectivity
- Review voltage limits

**DNP3 connection fails**:
- Check port 20000 is not in use
- Verify firewall settings
- Check DNP3 addresses match

**Modbus connection fails**:
- Check port 502 is not in use (may need sudo)
- Verify unit ID matches
- Check register addresses

### Debug Mode

```bash
# Enable debug logging
export LOG_LEVEL=DEBUG
python -m src.main
```

## License

See LICENSE file for details.

## References

- [Pandapower Documentation](https://pandapower.readthedocs.io/)
- [DNP3 Protocol](https://www.dnp.org/)
- [Modbus Protocol](https://modbus.org/)
- [Grid-STIX Ontology](https://github.com/argonne-citadel/grid-stix)

## Acknowledgments

This software was developed under U.S. Department of Energy award DE-CR0000049, issued by the Office of Cybersecurity, Energy Security, and Emergency Response (CESER). The prime contractor on this work was Iowa State University, and the ideas herein are influenced by conversations with them. The submitted manuscript has been created by UChicago Argonne, LLC, operator of Argonne National Laboratory. Argonne, a DOE Office of Science laboratory, is operated under Contract No. DE-AC02-06CH11357. The U.S. Government retains for itself, and others acting on its behalf, a paid-up nonexclusive, irrevocable worldwide license in said article to reproduce, prepare derivative works, distribute copies to the public, and perform publicly and display publicly, by or on behalf of the Government.