Metadata-Version: 2.5
Name: seetapsych-hertz
Version: 0.0.3rc1
Summary: Heart rate estimation modules for SeetaPsych
Project-URL: Homepage, https://github.com/seetapsych/seetapsych-hertz
Project-URL: Repository, https://github.com/seetapsych/seetapsych-hertz
Project-URL: Issues, https://github.com/seetapsych/seetapsych-hertz/issues
License: BSD 3-Clause License
        
        Copyright (c) 2026, Visual Information Processing and Learning (VIPL) group,
        Institute of Computing Technology, Chinese Academy of Sciences, Beijing, China;
        Southeast University, China;
        Beijing Seetatech Co., Ltd.
        All rights reserved.
        
        Redistribution and use in source and binary forms, with or without
        modification, are permitted provided that the following conditions are met:
        
        1. Redistributions of source code must retain the above copyright notice, this
           list of conditions and the following disclaimer.
        
        2. Redistributions in binary form must reproduce the above copyright notice,
           this list of conditions and the following disclaimer in the documentation
           and/or other materials provided with the distribution.
        
        3. Neither the name of the copyright holder nor the names of its
           contributors may be used to endorse or promote products derived from
           this software without specific prior written permission.
        
        THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
        AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE
        IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE
        ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR CONTRIBUTORS BE
        LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR
        CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF
        SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
        INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN
        CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE)
        ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
        POSSIBILITY OF SUCH DAMAGE.
License-File: LICENSE
Requires-Python: >=3.10
Requires-Dist: seetapsych-lib
Provides-Extra: all
Requires-Dist: numpy>=2.2.6; extra == 'all'
Requires-Dist: onnx>=1.20.1; extra == 'all'
Requires-Dist: onnxruntime-gpu<1.24; (sys_platform != 'darwin' and python_version <= '3.10') and extra == 'all'
Requires-Dist: onnxruntime-gpu>=1.24; (sys_platform != 'darwin' and python_version > '3.10') and extra == 'all'
Requires-Dist: onnxruntime<1.24; (sys_platform == 'darwin' and python_version <= '3.10') and extra == 'all'
Requires-Dist: onnxruntime>=1.24; (sys_platform == 'darwin' and python_version > '3.10') and extra == 'all'
Requires-Dist: opencv-python>=4.13; extra == 'all'
Requires-Dist: scipy>=1.15.3; extra == 'all'
Provides-Extra: dev
Requires-Dist: bandit>=1.7; extra == 'dev'
Requires-Dist: build>=1.4.4; extra == 'dev'
Requires-Dist: mypy>=1.11; extra == 'dev'
Requires-Dist: numpy>=2.2.6; extra == 'dev'
Requires-Dist: onnx>=1.20.1; extra == 'dev'
Requires-Dist: onnxruntime-gpu<1.24; (sys_platform != 'darwin' and python_version <= '3.10') and extra == 'dev'
Requires-Dist: onnxruntime-gpu>=1.24; (sys_platform != 'darwin' and python_version > '3.10') and extra == 'dev'
Requires-Dist: onnxruntime<1.24; (sys_platform == 'darwin' and python_version <= '3.10') and extra == 'dev'
Requires-Dist: onnxruntime>=1.24; (sys_platform == 'darwin' and python_version > '3.10') and extra == 'dev'
Requires-Dist: opencv-python>=4.13; extra == 'dev'
Requires-Dist: pytest>=8.0; extra == 'dev'
Requires-Dist: ruff>=0.6; extra == 'dev'
Requires-Dist: scipy>=1.15.3; extra == 'dev'
Requires-Dist: twine>=6.2.0; extra == 'dev'
Description-Content-Type: text/markdown

# SeetaPsych Hertz

> Heart rate estimation modules for SeetaPsych

## Usage

This project is already included in the seetapsych-lib default configuration. Download and use it via `seetapsych-manager download`.

For usage, refer to [SeetaPsych](https://github.com/seetapsych/seetapsych-lib).

You can additionally add this algorithm module using the following methods.

Heart rate estimation requires processing video or real-time video streams to extract heart rate information.

### WebUI

Run `seetapsych-webui` with the `--files` argument to use it.

```
seetapsych-webui --files seetapsych_hertz/modules/seeta.yml
```

### Programmatic Usage

Add the following code in your program to use this algorithm module.

```python
from seetapsych_lib.runtime.factory import Factory
from seetapsych_lib.runtime.pipeline import Pipeline

factory = Factory()
factory.load_file_modules("seetapsych_hertz/modules/seeta.yml")

pipeline = Pipeline(factory, ...)

pipeline.add_attributes("face/heart_rate")
```

### Module Catalog

| Module YAML Path | Package Name |
|---|---|
| `seetapsych_hertz/modules/ada-chrom.yml` | HeartRate-AdaChrom |
| `seetapsych_hertz/modules/seeta.yml` | HeartRate-Seeta |
| `seetapsych_hertz/modules/tiny-hr.yml` | HeartRate-TinyHR |

### AdaChrom

> Model-free rPPG heart rate estimation using adaptive chrominance analysis on skin ROI.

Module config: [ada-chrom.yml](seetapsych_hertz/modules/ada-chrom.yml)

| Package | Provides | Requires |
|---|---|---|
| HeartRate-AdaChrom | `face/heart_rate` | `face/dense_landmarks` |

**Description**

Adaptive chrominance rPPG heart rate estimator from adaptive forehead ROI, no neural model required.

**Parameters**

| Name | Type | Default | Description & Tuning |
|---|---|---|---|
| `window_samples` | integer | `300` | Sliding window frame count for HR estimation. Larger values reduce noise but increase latency; adjust based on real-time demand. |

**Models**

*(None)*

### SeetaHeartRateDetector

> Traditional signal-processing heart rate estimation from forehead skin pixels via chrominance + FFT analysis.

Module config: [seeta.yml](seetapsych_hertz/modules/seeta.yml)

| Package | Provides | Requires |
|---|---|---|
| HeartRate-Seeta | `face/heart_rate` | `face/dense_landmarks` |

**Description**

Signal-processing heart rate estimator using forehead ROI from dense landmarks with chrominance + FFT peak detection.

**Parameters**

| Name | Type | Default | Description & Tuning |
|---|---|---|---|
| `min_seconds` | number | `1` | Minimum buffered signal duration (seconds) before producing first HR estimate. Lower for faster startup, higher for stability. |
| `min_frames` | integer | `10` | Minimum frame count before HR estimation starts. Takes effect whichever is reached later between min_seconds and min_frames. |
| `max_frames` | integer | `300` | Maximum frames kept in the sliding analysis window. Larger windows smooth outliers but increase response lag to true HR changes. |

**Models**

*(None)*

### TinyHR

> Lightweight neural network for fast heart rate estimation directly from face video frames.

Module config: [tiny-hr.yml](seetapsych_hertz/modules/tiny-hr.yml)

| Package | Provides | Requires |
|---|---|---|
| HeartRate-TinyHR | `face/heart_rate` | `face/detection` |

**Description**

Fast RhythmFormer heart rate estimator using buffered face crops + Welch spectral analysis.

**Parameters**

| Name | Type | Default | Description & Tuning |
|---|---|---|---|
| `fps` | number | `30` | Expected camera/video FPS used for spectral analysis windowing. Mismatch with actual source FPS degrades HR accuracy. |
| `interval` | number | `1` | Seconds between consecutive HR estimates. Smaller intervals yield more updates with higher jitter; larger intervals are smoother but slower. |

**Models**

| Model | Recommended |
|---|---|
| `seeta-hertz-tinyhr.onnx` | ✓ |