=============================  ISOTOPE SPECTRUM  ==============================

This widget computes the photon emission lines (gamma rays, X-rays and
annihilation photons) of up to three radionuclides, weighted by their
activities. The result can be plotted, exported, or sent to the XOPPY POWER
widget to compute the power transmitted through filters.

The data come from MIRDspecs (https://mirdsoft.org/products/MIRDspecs), based
on the ICRP Publication 107 nuclear decay data. Access is through the python
package radionuclide-emission-db (C. Karafasoulis), which must be installed:

     python -m pip install radionuclide-emission-db


NETWORK AND CACHE
-----------------

- The list of available isotopes (~1250) is read from the MIRDspecs index
  (https://mirdsoft.org/resources/mirdspecs) every time the widget is opened.
  A network connection is therefore required. If the list cannot be read the
  widget opens, but the calculation stops with an error message.

- The spectrum of each isotope is downloaded the first time it is used, and
  saved in a cache directory. Following calculations read the cached file.
  The cache directory is (same convention as DABAX):

      Linux:   ~/.local/share/MIRDspecs   (or $XDG_DATA_HOME/MIRDspecs)
      macOS:   ~/Library/Application Support/MIRDspecs
      Windows: %LOCALAPPDATA%\MIRDspecs

  If that directory is not writable, a temporary directory is used.
  The NIST attenuation tables used by the internal filters are also
  downloaded on demand (one file per element) and cached in the
  sub-directory nist-attenuation of the cache directory.
  The cache can be safely deleted at any time; files are downloaded again
  when needed. The Output tab shows the cache directory and, for every
  isotope, whether its spectrum was read from the cache or downloaded.


INPUT PARAMETERS
----------------

Number of isotopes:  1, 2 or 3 isotopes are mixed.

Isotope i:  name of the isotope, e.g. Cs-137, Ba-137m, Co-60, Am-241
    (type in the combo box to search).

Activity i [Bq]:  activity of isotope i (decays/s). Note that daughters are
    NOT added automatically: e.g., the 661.7 keV gamma line of Cs-137 is
    emitted by its daughter Ba-137m, so Cs-137 must be combined with Ba-137m
    with activity 0.944 x A(Cs-137) (secular equilibrium, branching ratio).

Radiation type:  every MIRDspecs line is labelled with a type. The particle
    lines (alpha, beta, positron, Auger and conversion electrons) are always
    ignored. Among the photon lines, one selects:

      All photons                          Gamma + X-ray + Annihilation photon
      Gamma [from nucleus] + annihilation  Gamma + Annihilation photon
      X-ray [from atomic shells]           X-ray

    - Gamma: nuclear de-excitation (e.g. 661.7 keV of Ba-137m,
      1173 and 1332 keV of Co-60).
    - X-ray: emitted by the atomic shells after electron capture or internal
      conversion (e.g. Ba K lines ~32 keV after Cs-137 decay). They include
      many L, M... lines of very low energy (tens or hundreds of eV) with
      large yield. They dominate the number of photons per decay but carry
      little power.
    - Annihilation photon: the 511 keV photons from positron annihilation
      (e.g. F-18, yield 1.93 = 2 x positron yield).

    If an isotope has no lines of the selected type, an error is raised.

Intensity units:  Photons/s, or Photons in acquisition time
    (= photons/s x acquisition time).

Acquisition time [s]:  used only with "Photons in acquisition time".

Energy min, Energy max [keV]:  only lines with
    Energy min <= E <= Energy max  are kept (limits included). This is a
    simple cut of the lines. It also defines the range of the energy grid
    of the binned spectrum (see below). Energy min must be > 0.

Binning of the energy grid:  the regular energy grid of the binned
    spectrum starts at Energy min and is defined by either:
    - Number of energy points: the grid ends at Energy max, and the step is
      (Energy max - Energy min) / (number of points - 1).
    - Bin size [keV]: the step is exactly the bin size; the last point is the
      first one >= Energy max (it may exceed Energy max by less than one
      step), so that all lines up to Energy max are inside the grid.

Internal filters:  None, 1, 2 or 3 filters applied to the emission lines,
    e.g. to account for the source encapsulation or self-absorption.
    For each filter: material, thickness [mm] and density [g/cm3].

    Materials: there is no fixed list. Valid materials are:
    - any element with Z = 1 to 92 (the range of the NIST tables), given by
      its symbol, e.g. Be, Al, Ta, Au, Pb;
    - any compound formula that can be read by the xraylib CompoundParser,
      e.g. H2O, SiO2, C2H4, Cd0.9Zn0.1Te (elements with Z <= 92 only);
    - the following names (case insensitive) known by
      radionuclide-emission-db, with their default density:

          name(s)                     formula          density [g/cm3]
          pb, lead                    Pb               11.34
          al, aluminum, aluminium     Al                2.70
          fe, iron                    Fe                7.874
          cu, copper                  Cu                8.96
          w, tungsten                 W                19.25
          si, silicon                 Si                2.329
          h2o, water                  H2O               1.0
          nai                         NaI               3.67
          czt                         Cd0.9Zn0.1Te      5.78

    Density: "?" means default: the density in the table above if the
    material is one of these names, otherwise the density of the element
    from xraylib. For any other compound the density must be entered.

    Filtering mechanism: Beer-Lambert law (narrow beam), using the total
    cross section. For every line of energy E, and every filter of
    thickness t and density rho, the line intensity is multiplied by the
    transmission

        T(E) = exp( - (mu/rho)(E) x rho x t )

    The intensity after n filters is I = I0 x T1(E) x T2(E) x ... x Tn(E).

    (mu/rho)(E) [cm2/g] is the total mass attenuation coefficient, i.e.
    the total cross section per unit mass, from the NIST SRD 126 tables
    (X-Ray Mass Attenuation Coefficients, J.H. Hubbell and S.M. Seltzer).
    It includes all the interactions that remove a photon from the beam:
    photoelectric absorption, coherent (Rayleigh) and incoherent (Compton)
    scattering and pair production. All scattered photons are considered
    lost: there is no build-up of scattered photons, which is correct for a
    narrow beam (collimated source and detector) but underestimates the
    transmitted photons for a broad beam and thick filters.

    Details of the calculation (as implemented in radionuclide-emission-db):
    - The NIST table of each element is downloaded on demand and cached
      (see NETWORK AND CACHE).
    - (mu/rho) at the line energy is interpolated log-log between the
      tabulated energies. At an absorption edge (duplicated energy in the
      table) the value above the edge is used.
    - For compounds, the mixture rule is used:
          (mu/rho) = sum_i  w_i (mu/rho)_i
      with w_i the mass fraction of element i (from xraylib CompoundParser).
    - The NIST tables cover 1 keV - 20 MeV. Lines below 1 keV are removed
      when filters are used (transmission 0); their number is reported in
      the Output tab. (In practice, such soft photons are absorbed by any
      filter of a realistic thickness.)

    The filtered lines are used for the binned spectrum sent to POWER.
    Filters can also be applied in the POWER widget (with xraylib/DABAX
    attenuation): be careful not to apply the same filter twice.

OUTPUT
------

There are four plot tabs:

1) Emission lines: the lines are NOT binned. Every line is drawn as a
   vertical stick from 0 to its intensity:
      yield [photons/decay] x activity [Bq] (x acquisition time [s])
      ->  photons/s (or photons in the acquisition time)
   The stick height is the number of photons (/s) in that line; there is no
   line width and no "per eV" density. Lines with the same energy (e.g. the
   same line from different isotopes) are summed.
   With internal filters, the emitted lines are in blue and the lines after
   the filters in red.

2) Flux [photons/s/0.1%bw]
3) Spectral Power [W/eV]
4) Cumulated Power [W]

   Tabs 2-4 show the binned spectrum, in the standard XOPPY format for
   sources. It is the spectrum sent to POWER.
   It is made from the lines after the internal filters (if any).
   It is always per second (independent of the intensity units).

   Binning: each line at energy E, between the grid points E_k and E_k+1,
   is shared between these two points with linear weights (1-f) and f,
   with f = (E - E_k) / step. This preserves both the number of photons and
   the power (the weighted mean of E_k and E_k+1 is E). The densities are
   obtained dividing by the step (photons/s/eV), and the values at the two
   end points of the grid are doubled, because the trapezoid integration
   rule (used by POWER) gives them half weight. In this way, the integrals
   of the binned spectrum give exactly the totals of the lines:
      Flux     = photons/s/eV x 1e-3 x E           [photons/s/0.1%bw]
      Spectral power = photons/s/eV x E x e        [W/eV]
      Cumulated power = integral of the spectral power from Energy min [W]
   The last value of the cumulated power is the total power of the lines.
   The binning places the photons of a line on the grid points around it,
   so finer details (e.g. attenuation edges between two grid points) are
   resolved only with a step small enough.

Output tab:  cache and source information, the table of all lines (energy,
   intensity, type, isotope), the number of lines, the total (sum of lines)
   in photons/s and its power in W (or photons and energy in J for the
   acquisition time), and the binned grid with its integrated flux and power
   (equal to the totals of the lines). With internal filters, also the
   filters used (with the density and the NIST tables), a table of the
   lines with emitted intensity, transmission and intensity after filters,
   the totals after filters and the transmitted fractions of photons and
   power.

Script tab:  a python script reproducing the calculation with
   radionuclide-emission-db, including the binned spectrum.

Data sent (DataExchangeObject, named "BLACK_BODY" so that POWER accepts it):
   xoppy_data:  array (npoints, 4): energy [eV], flux [photons/s/0.1%bw],
                spectral power [W/eV], cumulated power [W]
   xoppy_data_lines:  array (nlines, 2): energy [eV], intensity of the
                summed lines (photons/s, or photons), after filters
   xoppy_data_lines_emitted:  the same, before filters


CONNECTION WITH POWER
---------------------

Connect the output to the XOPPY POWER widget to compute absorbed and
transmitted power through filters/mirrors. POWER uses the spectral power
column [W/eV] of the binned spectrum. POWER needs attenuation data at all
the grid energies: an Energy min below ~1 keV may not be covered by the
material tables, and POWER will then raise an error (e.g. "Spline
extrapolation is not allowed"). In this case increase Energy min.


REFERENCES
----------

- ICRP Publication 107: Nuclear Decay Data for Dosimetric Calculations.
  Ann. ICRP 38 (3), 2008.
- MIRDspecs: https://mirdsoft.org/products/MIRDspecs
- NIST SRD 126, X-Ray Mass Attenuation Coefficients (Hubbell and Seltzer):
  https://physics.nist.gov/PhysRefData/XrayMassCoef/
- radionuclide-emission-db: https://pypi.org/project/radionuclide-emission-db