Metadata-Version: 2.5
Name: pycontrol-gui
Version: 3.0.0b6
Summary: Qt desktop frontend for pycontrol-core.
Author: Karpova Lab contributors
License: GPL-3.0-or-later
License-File: LICENSE.txt
Classifier: Development Status :: 4 - Beta
Classifier: Intended Audience :: Science/Research
Classifier: License :: OSI Approved :: GNU General Public License v3 or later (GPLv3+)
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.12
Classifier: Topic :: Scientific/Engineering
Requires-Python: >=3.12
Requires-Dist: packaging>=24
Requires-Dist: pycontrol-core<3.1,>=3.0.0b4
Requires-Dist: pyqtgraph>=0.13.7
Requires-Dist: pyside6>=6.8
Provides-Extra: test
Requires-Dist: pytest-qt>=4.4; extra == 'test'
Requires-Dist: pytest-timeout>=2.3; extra == 'test'
Requires-Dist: pytest>=8; extra == 'test'
Description-Content-Type: text/markdown

# pycontrol-gui

`pycontrol-gui` is the Qt desktop frontend for `pycontrol-core`.

Core owns acquisition, recording, provenance, and the final `RunResult`. The GUI
owns operator workflows and displays core events through queued Qt signals.
For an architecture overview, start with the
[core walkthrough](../pycontrol-core/docs/core-walkthrough.md), then read the
[GUI integration guide](docs/architecture.md).

It provides the main pyControl operator workflows:

- Run one task on one setup.
- Edit and run multi-subject experiments.
- Manage setup names, ports, provisioned board identity, and setup variables.
- View live logs and plots.
- Use workspace task handlers, experiment handlers, task plotters, task
  controls, and addon settings.

## Install From PyPI

pyControl is installed once per machine as a global app. Install its lifecycle
manager, then install and launch the app:

```bash
uv tool install --prerelease if-necessary-or-explicit pycontrol-manager
pycontrol-manager app install
pycontrol-manager app status
pycontrol gui
```

On first launch, the welcome dialog offers to create or open a workspace.

Or install the app directly:

```bash
uv tool install --prerelease if-necessary-or-explicit --with-executables-from pycontrol-core pycontrol-gui
# or, in an existing Python environment
pip install --pre pycontrol-gui
```

Upgrade published packages with `pycontrol-manager app update`.

## Switch the Global App to Development Sources

Given a source root containing sibling `pycontrol-core/` and `pycontrol-gui/`
checkouts:

```bash
pycontrol-manager app source local /path/to/source-root
pycontrol gui
```

Both checkouts are editable, so source edits are immediately live in the same
global commands and OS launcher. `pycontrol-manager app update` refuses to
replace editable sources. Switch back to the newest published packages
explicitly:

```bash
pycontrol-manager app source pypi
```

For an isolated development environment instead, `pycontrol-gui/pyproject.toml`
already points uv at the sibling core checkout:

```bash
cd /path/to/source-root/pycontrol-gui
uv sync --locked --extra test
uv run pycontrol-gui /path/to/workspace
```

Run tests with Python's module form so stale local script shebangs do not get in
the way:

```bash
uv run python -m pytest
```

See [maintainability.md](docs/maintainability.md) for ownership and testing
guidance.

## Workspaces

Workspaces are plain data folders; the app is installed once and switches
between them. Open a workspace with **File -> Open Workspace...**, create
one with **File -> New Workspace...**, or pass a workspace path with
`pycontrol gui PATH`.

When `pycontrol gui` is launched without a path, it first searches the current
directory and its parents for a valid workspace. If none is found, it opens the
last valid workspace remembered from an earlier session. If there is no
remembered workspace—such as the first launch from outside a workspace—the
welcome dialog offers to create or open one. Opening or creating a workspace
remembers it for subsequent launches. An explicit path always takes precedence.

`pycontrol-gui --set-workspace PATH` records the workspace to open on next
launch without starting the GUI;
`pycontrol-gui --forget-workspace` clears the remembered workspace and recent
list so the next launch shows the welcome dialog again. Use
**File -> Reload Workspace** to refresh selectors after external file
changes.

The GUI uses the standard `pycontrol-core` workspace layout:

| Path | GUI use |
| --- | --- |
| `tasks/` | Task selector in Run task and Experiments (task files only). Each task folder also holds the task's handlers, plotter and controls. |
| `hardware_definitions/` | Hardware-definition selector and setup validation. |
| `devices/` | Workspace-local device drivers for task sharing and setup maintenance. |
| `experiments/*.json` | Experiment editor and run view. |
| `settings.json` / `setups.json` | Workspace settings and setup registry. |

Workspace `settings.json` includes the default data directory plus GUI settings
such as startup tab, plot update frequency, font sizes, and whether task
controls are mounted by default. Relative data paths are resolved against the
workspace root, and users can still override the data directory for an
individual run. GUI application preferences (`QSettings`) store user-local
state such as the selected workspace root and splitter layouts.

## Run Task

The Run task tab connects to one setup, uploads an optional hardware definition,
loads a task, and drives a core `Run` through start and completion. Core records
the data while the GUI routes live events into logs, controls, and plots.

The live log view supports filtering and autoscroll, and task handlers can
publish status snapshots with `TaskHandler.update_status(...)` for the Run
task and experiment status panels. A `Progress` value in a snapshot is drawn as
a progress bar, with optional fill and text colours.

Task files can select optional GUI helpers:

```python
v.handler = "sequence"
v.plotter = "SequencePlotter"
v.controls = "reward_panel"
```

Missing plotters and controls fall back to the default plotter and controls.
Task-handler preparation or invalid addon selection can block starting; inspect
the displayed error before retrying.

## Experiments

The Experiments tab edits experiment JSON files and creates one subject panel
per active subject/setup assignment. Each subject panel owns its own
`SessionRuntime` with its own controller, worker thread, bus adapter, board
session and core `Run`, plus controls and plots. Sessions own separate ports and
recordings, while all panels share the GUI thread and process.

Experiments can also select an optional hardware-test task. When enabled, the
run view uploads and runs that task for each subject before preparing the main
experiment task.

An active Run task run (`RUNNING`) locks the Experiments and Setups tabs. An
open experiment run view locks Run task and Setups so one workflow owns the
shared application state at a time.

The Qt experiment editor exposes hardware definitions as first-class fields. For
tasks that import `hardware_definition`, the editor shows a hardware-definition
selector (saved to the experiment's `hardware_definition` field) and the
subjects table previews the effective hwdef per subject. The effective hwdef is
the experiment override, else the setup's `hardware_definition` default. Run
task offers the same selector, and Setups store a default hwdef per setup.

## Addons And Trusted Code

Workspace addons are trusted Python and execute in the GUI process.

- Addons live next to their task in its task folder and are selected by file
  stem from the task (`v.handler`, `v.plotter`, `v.controls`); see
  pycontrol-core `docs/task-folders.md`.
- Task plotters subclass `pycontrol_gui.plotting.TaskPlotter`.
- Task controls can be declarative JSON or
  custom Python widgets exporting `build_controls(parent, context)`. The GUI
  renders JSON specs with `TaskControlsPanel` and embeds Python widgets directly.
- Task and experiment handlers are loaded through `pycontrol-core`.
- `SETTINGS` declarations for task handlers, experiment handlers, and task
  plotters are edited in the GUI Settings dialog and saved under
  `settings.addons.*`. Task controls are configured through task variables
  or declarative control defaults instead.
- The Settings dialog shows a configurable-file page for built-in plotting
  defaults and each addon file with valid `SETTINGS`. Each page has a
  `Use defaults` button that resets only that file's settings before saving.

Secret settings are masked in the GUI but still saved in `settings.json`.

## Task Sharing And Sandboxes

The Run task tab can export a selected task and its workspace-local dependencies
as a protocol bundle ZIP. **File -> Switch to Sandbox...** opens a sandbox
manager that can create an isolated workspace from a shared ZIP, run it against
local setups, and return to the parent workspace with a visible sandbox banner.
See [task-sharing.md](docs/task-sharing.md).

## Plotting Diagnostics

The workspace `GUI.plot_update_frequency_hz` setting controls live plot redraws;
new workspaces default to `35 Hz`. Plot data ingestion still happens through the
session event stream, so lowering the redraw rate reduces GUI paint work without
dropping incoming events. Built-in plot history is bounded; queued Qt event
delivery is not. Slow GUI callbacks can still accumulate display delay and memory
use, which must be measured at the intended rig and sample workload.

For hardware performance checks, launch with plot profiling enabled:

```bash
PYCONTROL_PLOT_PROFILE=1 pycontrol-gui /path/to/workspace
```

Set `PYCONTROL_PLOT_PROFILE_INTERVAL_S` to change the reporting interval. The
GUI logs `[plot-profile]` lines with call counts plus average and maximum
latency for `process_batch()` and `update_plot()` spans.

## Import Stability

The supported import surfaces are:

- `pycontrol_gui.plotting`
- `pycontrol_gui.error_logging`
- `pycontrol_gui.resources`

Widgets, controllers, and workspace models are application internals. Tests may
import them, but downstream code should not treat them as stable.

## Error Logging

`pycontrol-gui` writes host-side diagnostics to a rotating `ErrorLog.txt` file:

1. `<workspace root>/ErrorLog.txt`
2. `~/.pycontrol-gui/logs/ErrorLog.txt`
3. `./ErrorLog.txt`

Open **Help -> Error Log** (`Ctrl+E`) to inspect or clear the current log.
Run bundles (`.pycontrol.zip`) are separate and stay in the experiment data
directory.

## Documentation

New to the project? Use this reading order:

- [Core walkthrough](../pycontrol-core/docs/core-walkthrough.md) - canonical source guide to ownership, lifecycle, data flow, and failure paths.
- [GUI integration](docs/architecture.md) - commands, threads, results, and shutdown around core.
- [Documentation index](../rewrite-docs/README.md) - the wider documentation map; older rendered tours may describe earlier revisions.

GUI guides:

- [Architecture, threading, and data flow](docs/architecture.md)
- [Task sharing and sandboxes](docs/task-sharing.md)
- [Task plotter addons](docs/plot-addons.md)
- [Task controls](docs/task-controls.md)
- [Addons in the GUI](docs/addons.md)
- [Maintainability notes](docs/maintainability.md)
- [Changelog](docs/changelog.md)
- [Contributor workflow](CONTRIBUTING.md)

## Verify a release installation

Build both repositories with `uv build --wheel`, then run from this checkout.
These filenames match the current checkout versions; use the actual candidate
filenames when release versions are assigned:

```bash
uv run python tools/check_wheels.py ../pycontrol-core/dist/pycontrol_core-3.0.0b4-py3-none-any.whl dist/pycontrol_gui-3.0.0b6-py3-none-any.whl
```

This installs the wheels into a temporary environment and opens/closes a real
window with a fresh workspace. Python runs in isolated mode, outside both
checkouts. When the candidate version differs from the GUI's declared core
minimum, the script also installs that minimum from the package index. When
they match, it tests only the supplied candidate wheel. The next core release
is `3.0.0b4`, matching the GUI floor; use the final candidate, not an earlier
unpublished development build with the same version label.

A release still needs validated clean candidate artifacts and physical F4/H7
acceptance on supported operating systems at the intended sustained workload.
Follow core's
[hardware acceptance procedure](../pycontrol-core/docs/release-acceptance.md).
The headless Supervisor's finite grace also needs an explicit workload/timeout
decision: slow preparation or packaging can consume it. Publish core before GUI
so the chosen minimum is available to installers. Passing tests or this smoke
check alone does not approve stable distribution.
