Metadata-Version: 2.4
Name: fairland-modbus
Version: 0.1.0
Summary: Manage inverter pumps, heat pumps & water treatment devices from Fairland Group
Keywords: fairland,aquark,modbus,inverter,heat pump,home-assistant
Author: Ringo De Smet
Author-email: Ringo De Smet <ringo@de-smet.name>
License-Expression: Apache-2.0
License-File: LICENSE
Classifier: Programming Language :: Python :: 3
Classifier: Topic :: Home Automation
Requires-Dist: modbus-connection>=4.12.5
Maintainer: Ringo De Smet
Maintainer-email: Ringo De Smet <ringo@de-smet.name>
Requires-Python: >=3.12
Project-URL: homepage, https://github.com/hardes-bv/python-fairland-modbus
Project-URL: repository, https://github.com/hardes-bv/python-fairland-modbus
Project-URL: documentation, https://github.com/hardes-bv/python-fairland-modbus
Project-URL: Bug Tracker, https://github.com/hardes-bv/python-fairland-modbus/issues
Project-URL: Changelog, https://github.com/hardes-bv/python-fairland-modbus/releases
Description-Content-Type: text/markdown

# fairland-modbus

An asynchronous Python client for Fairland Group pool equipment over Modbus,
built on [`modbus-connection`][modbus-connection]. The library declares the
register layout of each device and decodes it into typed values. The caller
owns the connection and hands the library a `ModbusUnit`, so the same code runs
on the pymodbus and tmodbus backends, and inside Home Assistant.

## Supported devices

| Device | Module | Status |
| --- | --- | --- |
| Inverter pool heat pumps with an MWH216 or MWH298 board (Fairland IPHCR and InverX, and the same board under other brands) | `fairland_modbus.heat_pump` | Written from the Fairland register table and tested against a simulator of it. Tested on a Geco GEPAC08 with an MWH298-V3 board. Feedback from other units welcome. |

## Install

```bash
pip install fairland-modbus
```

The library itself needs no Modbus backend. Install one to talk to a device:

```bash
pip install "modbus-connection[tmodbus]"
```

## Heat pumps with an MWH216 or MWH298 board

### Which heat pumps have this board

Owners have published working setups on this register table for:

* Fairland IPHCR45 (spdr870), and an IPHCR on an MWH298 board with super silence;
* Fairland InverX Vertical;
* a Madimack 9 kW heat-only unit, a rebadged Fairland;
* a BWT pool heat pump, with the ESPHome setup of rstcologne.

Not every Fairland heat pump has this board. The PC1004 board (VBIV, Norsup and
some Fairland units) answers on another port and with another register map: it
fails `async_validate()` with `NotAFairlandDeviceError`. An Aquaforte unit with an
MWH367 board reads the same addresses, but its owner codes the working mode
differently (0 silence, 1 smart, 2 turbo), so that board is not claimed here.

Heat-only units exist: on those, the board keeps heating when asked to cool.

### Wiring

The board has a 4-pin RS485 port, the one meant for the optional Wi-Fi module,
marked `B`, `A`, `G` (ground) and `+12V`. Wire `A`, `B` and `G` to an RS485 to
Ethernet gateway, or to a USB RS485 adapter. The line runs at 9600 baud, 8 data
bits, no parity, 1 stop bit, and the board answers at unit ID 1.

A gateway must be set to translate Modbus TCP to Modbus RTU (on a Waveshare
RS485 to ETH, the "Modbus TCP to RTU" protocol).

### Usage

```python
import asyncio

from modbus_connection import ModbusTcpParams
from modbus_connection.tmodbus import ModbusConnection

from fairland_modbus.heat_pump import FairlandHeatPump, Function, WorkingMode


async def main() -> None:
    connection = ModbusConnection(ModbusTcpParams(host="192.168.1.200", port=502))
    try:
        heat_pump = FairlandHeatPump(connection.for_unit(1))
        await heat_pump.async_validate()

        report = await heat_pump.async_update()
        print(report.updated, report.failed)
        print(heat_pump.readings.inlet_water_temperature)
        print(heat_pump.settings.function, heat_pump.target_temperature)
        print(heat_pump.status.active_codes)

        await heat_pump.async_set_function(Function.HEATING)
        await heat_pump.async_set_target_temperature(28)
        await heat_pump.async_set_working_mode(WorkingMode.SILENCE)
    finally:
        await connection.close()


asyncio.run(main())
```

### How the board is read

The register table sets two rules, and the board "may return incorrect data"
when a read breaks them:

* a read must start at an address the table allows, and
* it must cover exactly 48 coils or discrete inputs, or exactly 3 registers.

The table also asks for at least 60 ms between two requests. The library
follows all three rules. One poll takes 12 requests: 1 coil block, 2 discrete
input blocks, 5 input register blocks and 4 holding register blocks.

### What is read and written

| Space | Addresses | Content |
| --- | --- | --- |
| Coils | 0, 1 | Power, forced defrost. Coil 2 (factory reset) is never written. |
| Discrete inputs | 0 to 17 | On, defrosting, DIN1 to DIN5 (DIN2 is the remote on/off contact, DIN3 the water flow switch on a GEPAC08), OUT1 to OUT9, malfunction, compressor demand |
| Discrete inputs | 48 to 91 | Fault and protection codes E0 to Ed, P0 to PA, F0 to Fb |
| Input registers | 0 to 14 | Compressor, PFC voltage, water and refrigerant temperatures, current, expansion valve, fan |
| Holding registers | 0 to 10 | Function, working mode, the three setpoints, pump mode and the service parameters P1 to P5 |

Temperatures come in the table's two encodings: type 1 is `raw / 2 - 30`,
type 2 is `raw / 2`. Setpoints step by one degree.

The working mode takes 0 (smart), 1 (silence) and 3 (turbo) per the table.
Value 2 (super silence) is not in the table, but owners of IPHCR heat pumps use
it. Boards do not take every mode. A GEPAC08 takes silence, takes smart only
while the compressor runs, and acknowledges turbo and super silence without
switching to them. The library reads the mode back, and raises
`FairlandRefusedError` when the board kept its mode or answered the write with
an exception.

### Errors

The library never leaks a transport exception:

| Exception | Meaning |
| --- | --- |
| `FairlandTimeoutError` | The link is up but the heat pump does not answer, like a gateway answering exception 0B because the pump is off. |
| `FairlandConnectionError` | The link itself failed. |
| `FairlandRefusedError` | The board answered and refused the request. |
| `NotAFairlandDeviceError` | The device answers, but not like this board. |
| `FairlandError` | The base class, also raised for a value the table does not allow. |

A block that fails during `async_update()` lands in the returned report, so a
caller can mark only the values of that block as unavailable.

## Development

This is a [uv][uv] project:

```bash
uv sync
uv run pytest          # unit tests on the mock, and end-to-end tests
uv run ruff check .
uv run mypy
```

`tools/simulator.py` simulates a heat pump from the register table alone. It
serves Modbus TCP or RTU, and refuses any read that breaks the block rules:

```bash
uv run python tools/simulator.py --tcp 5020
uv run python tools/simulator.py --tcp 5020 --fault E3
uv run python tools/simulator.py --tcp 5020 --refuse-working-mode
uv run python tools/simulator.py --tcp 5020 --gateway-silent
uv run python tools/simulator.py --tcp 5020 --other-board
```

## Sources

* The Fairland register table for the PC boards MWH216 and MWH298, as published
  by [spdr870/fairland_iphcr45_modbus][spdr870].
* The fault code meanings from the Fairland InverX installation manual.
* The super silence mode, the InverX, MWH298, BWT and PC1004 reports, from the
  [Home Assistant community thread][thread].
* The DIN terminals, from the Madimack setup of [Elwell/pool-heatpump][elwell].
* The working mode behaviour and the DIN3 water flow switch, from the Geco
  GEPAC08 field tests of [Locodice67/Pool-Heat-Pump-IPHCR45-Modbus][locodice67].

None of these projects carries a license, so no code was taken from them: the
module is written from the register table.

## License

Apache License 2.0, see [LICENSE](LICENSE).

[modbus-connection]: https://github.com/home-assistant-libs/modbus-connection
[uv]: https://docs.astral.sh/uv/
[spdr870]: https://github.com/spdr870/fairland_iphcr45_modbus
[thread]: https://community.home-assistant.io/t/controlling-a-fairland-pool-heatpump-eliminating-tuya/579467
[elwell]: https://github.com/Elwell/pool-heatpump
[locodice67]: https://github.com/Locodice67/Pool-Heat-Pump-IPHCR45-Modbus