LevelTypeLocationMessage
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshot.element[25].type[0].profile[0]There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/translation'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.1.0, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/translation' to 'http://hl7.org/fhir/StructureDefinition/translation|5.2.0'
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshot.element[43].type[0].profile[0]There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.1.0, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshot.element[48].type[0].profile[0]There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.1.0, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.differential.element[7].type[0].profile[0]There are multiple different potential matches for the url 'http://hl7.org/fhir/StructureDefinition/data-absent-reason'. It might be a good idea to fix to the correct version to reduce the likelihood of a wrong version being selected by an implementation/implementer, or use the [IG Parameter `pin-canonicals`](https://hl7.org/fhir/tools/CodeSystem-ig-parameters.html). Using version '5.2.0', found versions: 4.0.1, 5.1.0, 5.2.0. Suggested fix: change the canonical reference from 'http://hl7.org/fhir/StructureDefinition/data-absent-reason' to 'http://hl7.org/fhir/StructureDefinition/data-absent-reason|5.2.0'
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshotThe slice 'observationText' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshotThe slice 'observationCode' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshotThe slice 'numericQuantityMeasurement' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshotThe slice 'numericRangeMeasurement' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshotThe slice 'numericRatioMeasurement' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
warninginvalidStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshotThe slice 'numericSampledDataMeasurement' on path 'Observation.component' is not marked as 'must-support' which is not consistent with the element that defines the slicing, where 'must-support' is true
warningbusiness-ruleStructureDefinition.where(url = 'https://github.com/BIH-CEI/RareLink/StructureDefinition/rarelink-ips-measurement-radiology')The Implementation Guide contains no examples for this profile
informationinformationalStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinitionValidate resource against profile http://hl7.org/fhir/StructureDefinition/StructureDefinition|4.0.1
informationbusiness-ruleStructureDefinition/rarelink-ips-measurement-radiology: StructureDefinition.snapshot.element[13].slicing.discriminator[0]The discriminator type 'pattern' is deprecated in R5+. For future compatibility, you could consider using type=value with a pattern[x] instead (if this is not an inherited slicing)