Synaptipy User Guide
This document describes installation, configuration, and operation of Synaptipy for electrophysiology data visualization and analysis.
Table of Contents
Installation
System Requirements
Operating Systems:
macOS 11.0 (Big Sur) or later
Windows 10/11 (64-bit)
Linux (Ubuntu 20.04+, Fedora 35+, or equivalent)
Hardware:
CPU: Multi-core processor (quad-core or better recommended for batch processing)
RAM: 8 GB minimum, 16 GB recommended for large recordings (>500 MB)
Display: 1920x1080 resolution or higher recommended for optimal interface layout
GPU: Optional - Experimental opt-in OpenGL hardware acceleration is available in Edit > Preferences under the Performance tab (
Enable Hardware Acceleration (OpenGL) - Experimental, disabled by default; requires application restart); a discrete GPU improves rendering throughput on high-density traces
Software Requirements:
Python 3.10-3.12 (3.11 recommended)
Anaconda or Miniconda (recommended) or pip
Dependencies
Dependencies are automatically installed during package installation:
PySide6 - Qt6 bindings for Python (GUI framework)
PyQtGraph - plotting library (with experimental OpenGL support)
Neo - electrophysiology file I/O (Garcia et al., 2014, Front. Neuroinformatics doi:10.3389/fninf.2014.00010)
PyNWB - NWB data export (Rubel et al., 2022, eLife doi:10.7554/eLife.78362)
Standard Installation
WARNING: PySide6 must remain pinned to version 6.7.3 due to QTBUG-130070.
Synaptipy is available both as a standalone application and as a Python package.
Default Install (PyPI)
The recommended approach for most users is to install Synaptipy directly via pip into a standard Python environment (Python 3.10-3.12).
pip install synaptipy
# Optional: include pyabf fallback reader alongside Neo
pip install "synaptipy[formats]"
Conda Install
If you prefer using Anaconda or Miniconda, create a dedicated environment using the repository’s environment file:
git clone https://github.com/anzalks/synaptipy.git
cd synaptipy
conda env create -f environment.yml
conda activate synaptipy
pip install synaptipy
Standalone Application
Pre-built installers for Windows, macOS, and Linux are published on the GitHub Releases page:
Windows: Download and execute
Synaptipy_Setup_<version>.exe.macOS (Apple Silicon): Download
Synaptipy_<version>_macOS_arm64.dmg, open the disk image, and drag Synaptipy to theApplicationsfolder. Because release.dmgbuilds use ad-hoc code signing, runxattr -cr /Applications/Synaptipy.app(or approve the app in System Settings > Privacy & Security) if macOS Gatekeeper blocks the first launch.macOS (Intel): Download
Synaptipy_<version>_macOS_x86_64.dmg, open the disk image, and drag Synaptipy to theApplicationsfolder (runxattr -cr /Applications/Synaptipy.appif Gatekeeper blocks the first launch).Linux: Download
Synaptipy-<version>-x86_64.AppImage, mark it executable (chmod +x Synaptipy-<version>-x86_64.AppImage), and launch it. On distributions without FUSE 2 pre-installed (such as Ubuntu 24.04+), installlibfuse2t64/libfuse2or launch with./Synaptipy-<version>-x86_64.AppImage --appimage-extract-and-run.
Developer Installation
For developers, users who want to modify the application, or users working from the main branch, install from source using Conda/Miniconda:
git clone https://github.com/anzalks/synaptipy.git
cd synaptipy
conda env create -f environment.yml
conda activate synaptipy
pip install -e ".[dev]"
Getting Started
Running the Application
After installation, run the application using one of these methods:
Using the installed entry point:
synaptipy
Using the Python module:
python -m synaptipy
User Interface Overview
The Synaptipy interface consists of three main tabs:
Explorer Tab: View and navigate through data files, with interactive plotting
Analyser Tab: Perform automated analyses on the loaded data
Exporter Tab: Export data and results to standard formats
Demo Data
A set of example recordings may be downloaded automatically for testing purposes.
Select Help > Download Demo Data… A banner appears below the menu bar.
Select Download Demo Data. The application downloads five example recordings from the public repository to
~/Documents/SynaptiPy_Demo/:File
Format
Description
2023_04_11_0018.abfABF v2
Whole-cell current-clamp, step protocol
2023_04_11_0019.abfABF v2
Whole-cell current-clamp, ramp protocol
2023_04_11_0021.abfABF v2
Voltage-clamp, IV curve
2023_04_11_0022.abfABF v2
Optogenetic stimulation protocol
240326_003.wcpWinWCP
WinWCP current-clamp recording
Upon completion, the banner closes and the first ABF file is opened in the Explorer Tab.
The Help > Download Demo Data… menu item is disabled for the session (and on subsequent launches if files are already present).
Note: An internet connection is required. Files already present are not re-downloaded. If a download is interrupted, partially written files are removed.
Loading Data
Supported File Formats
File I/O is handled through the Neo library (Garcia et al., 2014, Front. Neuroinformatics, doi:10.3389/fninf.2014.00010). Synaptipy loads any recording format for which Neo provides a reader - this includes whole-cell patch-clamp and intracellular recordings as well as extracellular, sharp-electrode, and multi-channel data, provided the file format is supported. Confirmed formats include:
Format |
Extension(s) |
Acquisition System |
|---|---|---|
Axon Binary Format |
|
Axon / Molecular Devices |
WinWCP |
|
Strathclyde Electrophysiology Software |
CED / Spike2 |
|
Cambridge Electronic Design |
Igor Pro |
|
WaveMetrics |
Intan |
|
Intan Technologies |
Neurodata Without Borders |
|
NWB standard |
BrainVision |
|
Brain Products |
European Data Format |
|
EDF/EDF+ |
Plexon |
|
Plexon |
Open Ephys |
|
Open Ephys |
Tucker Davis Technologies |
|
TDT |
Neuralynx |
|
Neuralynx |
NeuroExplorer |
|
NeuroExplorer |
MATLAB |
|
- |
ASCII / CSV |
|
- |
For the full list of Neo-supported formats, see the Neo I/O documentation.
Note: Allen Cell Types Database NWB files (NWB format 2.2-2.3) may produce
UserWarning: ignoring namespacemessages when opened. These are benign version-mismatch warnings frompynwband do not affect data integrity. All voltage traces and stimulus waveforms are read accurately.
Opening Files
Click “Open File…” in the menu or use the shortcut (
Ctrl+OorCmd+O)Navigate to your data file and select it
The file opens in the Explorer tab
If other files with the same extension exist in the folder, they are available for navigation with Prev / Next File - this applies whether you opened one file or many, and whether you used the menu, drag-and-drop, or Help > Download Demo Data
Using the Explorer Tab
The Explorer tab has three resizable panels: the Configuration panel on the left, the Plot area in the centre, and the File / Analysis panel on the right. Drag the divider handles between the panels to resize them to suit your screen. The default widths are 320 px (left), 800 px (centre), and 360 px (right).
Plot Options
Plot Mode:
“Overlay All + Avg”: Shows all trials with the average highlighted
“Cycle Single Trial”: Shows one trial at a time with navigation controls
Performance:
_force_opaque_trials: For datasets with >10 overlapping trials, enable “Force Opaque Single Trials” in View > Plot Customization… to improve rendering performance.
Cross-File Trial Averaging: While in “Cycle Single Trial” mode, you can manually build a grand average from any combination of files and trials across the entire session:
Use the “Mark Current Trial” button to add the currently displayed trial - including any active preprocessing transforms - to the pending selection set.
Navigate freely between files (even files of different durations or sampling protocols) and continue marking trials. The pending selection accumulates until you add it to the Analysis Set.
Click “Add Marked Trials to Set” to move the pending selections into the Analysis Set used by the Analyser tab. Marks are cleared automatically after adding, so clicking the button again without marking new trials produces a “No trials marked” notice rather than an “already added” warning.
Enable “Plot Selected Avg” to overlay the grand average on the current recording view.
Sending to the Analyser: Once you have built an Analysis Set in the Explorer, switch to the Analyser tab, select “Cross-File Average” as the data source, and choose any registered analysis routine. The Analyser displays faint per-trial traces alongside a bold grand average so that trial-to-trial variability remains visible. The header label shows the item count and file count (e.g. “3 items (2 files)”) so you always know how many trials are included.
Compatibility and alignment: The Analyser selects channels by their channel ID, not their display position. It averages only sources with that channel, a recognised compatible physical dimension, and the same relative acquisition-time origin. Voltage inputs are converted to mV and current inputs to pA before pooling. Compatible recordings with different sample counts are interpolated to a common physical time axis; samples outside a recording’s acquisition interval do not contribute. A compatibility dialog lists every excluded source and its reason, while the included sources remain available for analysis. Cross-file averaging is aligned to relative acquisition time; stimulus-onset and manual-marker alignment are not applied automatically, so align recordings externally when their stimulus timing differs.
Channel Selection: Choose which channel to view from the dropdown
Channel Visibility: Use the per-channel show/hide checkboxes to hide channels you are not inspecting. When a channel is hidden its plot row collapses entirely - no blank white space remains in the canvas. Re-checking the box restores the row immediately.
Downsampling: Enable/disable automatic downsampling for large datasets
Interactive Cursor: Enable crosshair cursors to place persistent markers at specific (time, amplitude) coordinates on the trace. In Delta Mode, successive cursor placements report the difference (\(\Delta t\), \(\Delta V\) or \(\Delta I\)) between points. Placed readout labels can be left-dragged away from traces (with a dashed leader line) and double-clicked to reset; use Undo and Clear to manage placed cursors.
Trial Quality Metrics: Displays series resistance (\(R_s\)), membrane capacitance (\(C_m\)), and signal-to-noise ratio (SNR) for the current trial, extracted from the recording metadata. Values update automatically during trial navigation.
Using the Analyser Tab
The Analyser tab provides 16 built-in analysis routines organised into five module tabs. Each sub-tab is auto-generated from registry metadata and provides parameter widgets, an interactive plot, a results table, and plot overlays.
The five Analyser pillars are:
Pillar |
Registry name |
What it covers |
|---|---|---|
Intrinsic Properties |
|
RMP, Rin, Tau, Sag Ratio, I-V Curve, Capacitance |
Spike Analysis |
|
Spike detection, Phase-plane analysis |
Excitability |
|
F-I curve, Burst analysis, Spike Train Dynamics |
Synaptic Events |
|
Event detection (amplitude, template) |
Evoked Responses |
|
Evoked Sync, Paired-Pulse Ratio, Stimulus Train (STP) |
All analysis sub-tabs share the following interface behaviours:
Preprocessing indicator - A coloured banner appears at the top of the Analyser whenever preprocessing (baseline subtraction, digital filtering) is active. The banner lists each active step so the operator is always aware that the analysed signal differs from the raw acquisition.
Session count badge - The “Add to Session” and “View Session” buttons display a count of accumulated results (e.g. “Add to Session (5)”). This provides an at-a-glance indication of session progress without opening the session summary.
Auto-save - Session state is persisted automatically every five minutes to reduce the risk of data loss during prolonged recording sessions.
Free-form numeric input - Number fields accept freely typed values; intermediate states (empty field, a lone minus sign, etc.) are tolerated while typing. Stepping uses adaptive decimal increments.
Parameter validation feedback - Parameters outside their valid range are highlighted with a red border, providing immediate visual indication without blocking interaction.
Parameter tooltips - All parameter widgets display descriptive tooltips drawn from the analysis registry metadata, describing what the parameter controls and its expected units.
Interactive vs Manual mode - Sub-tabs that have draggable plot regions (e.g. Rin, Tau, Capacitance) expose a mode selector. In Interactive mode the time-window spinboxes are read-only and driven by the plot regions. Switching to Manual mode unlocks all spinboxes for direct entry.
Conditional parameter visibility - Parameters irrelevant to the current clamp mode or analysis type are hidden automatically.
Draggable statistical annotations - Main-plot and popup curve-fit overlays display quantitative badges (\(R^2\), regression slope, \(\tau\), event counts) directly on the figure. Left-drag any badge to move it off underlying traces (revealing a dashed leader line to its fitted curve), or double-click the badge to snap it back to its default position.
Input Resistance/Conductance Analysis
Select data for analysis from the Explorer tab
Switch to the Analyser tab and select the Input Resistance sub-tab
Choose analysis mode:
Interactive Mode: Drag the blue (baseline) and red (response) regions on the plot - the time-window spinboxes update in real time and become read-only
Manual Mode: Unlock the spinboxes and type time windows directly
Enable Auto-Detect Pulse (
auto_detect_pulse) to locate step edges automatically from the stimulus or clipped voltage derivative. If auto-detection produces invalid windows (e.g. due to action potentials in the trace), the analysis falls back to the current spinbox values and updates the spinboxes to reflect the windows actually usedResults display:
Mean, peak, and steady-state input resistance (
rin_mohm,rin_peak_mohm,rin_steady_state_mohm) in MOhmConductance (
conductance_us) in uSVoltage deflection (
voltage_deflection_mv) and current step (current_injection_pa)
Click “Add to Session” to store the analysis for later export
Baseline/RMP Analysis
Select a voltage channel for analysis and switch to the Baseline (RMP) sub-tab (
rmp_analysis)Specify Start Time (s) (
baseline_start) and End Time (s) (baseline_end), or enable Auto-Detect Stable Segment (auto_detect) with Auto Window (s) (window_duration) and Step Duration (s) (step_duration) to locate the minimum-variance baseline segment automaticallyOptionally configure Rs Blanking (ms) (
rs_artifact_blanking_ms, default0.5 ms) to skip initial series-resistance artifacts and LJP Correction (mV) (ljp_correction_mv, \(V_{\text{true}} = V_{\text{recorded}} - \text{LJP}\))The analysis computes the arithmetic mean resting potential (
rmp_mv), baseline standard deviation (rmp_std, withrmp_mv_plus_sdandrmp_mv_minus_sdoverlay bounds), per-sweep values (rmp_per_sweep) and cross-sweep drift rate (rmp_drift_rate_mv_per_sweep), and single-sweep baseline drift (estimated via ordinary least-squares linear regression after pre-smoothing with a 50 ms uniform moving average to suppress high-frequency electronic noise)Add results to the session as needed
Evoked Responses
The Evoked Responses tab contains three analysis sub-tabs for stimulus-evoked measurements.
Evoked Sync
Load a recording that contains a TTL/digital stimulus channel alongside the signal channel
Switch to the Evoked Sync sub-tab (
optogenetic_sync) in the AnalyserSelect the TTL channel from the channel selector and set the TTL Threshold (V) (
ttl_threshold) used to binarise the stimulus signalChoose Event Type (
event_detection_type):Spikes - threshold-crossing AP detection; set AP Threshold (mV) (
spike_threshold)Events (Threshold) - adaptive prominence threshold detection; set Event Threshold (pA/mV), Event Direction, and Refractory (s)
Events (Template) - matched-filter cross-correlation; configure Template Kernel Shape (
template_kernel_shape:bi-exponentialormono-exponential, defaultbi-exponential), Tau Rise (ms), Tau Decay (ms), Template Threshold (SD), Template Direction, and Template Multipliers (template_kernel_multipliers, comma-separated decay scaling factors, default"1.0, 2.0, 3.0"). By default, a bank of three kernels scaled at 1x, 2x, and 3x the decay time constant is cross-correlated with the trace and events are detected on the pointwise maximum of the z-scored matched-filter traces to tolerate dendritic cable filtering. Only the parameters relevant to the selected detection mode are shown.
Set Response Window (ms) to define how far after each TTL onset to search for an event, and configure Amplitude Window (ms), Baseline Window (ms), Artifact Blanking (ms), and Peak Polarity (
max,min, orabs)Results include
optical_latency_ms,response_probability,response_probability_pct,spike_jitter_ms,mean_response_amplitude,response_amplitude_sd,stimulus_count,Success Count,Failure Count, andevent_countClick “Add to Session” to store for later export
Paired-Pulse Ratio
Load a paired-stimulus or multi-pulse train recording
Switch to the Paired-Pulse Ratio sub-tab (
paired_pulse_ratio)Set Number of Pulses (
n_pulses, default 2; supports \(N \ge 2\))Enable Detect Stim from TTL (
use_ttl) to read stimulus onsets from a TTL channel, or disable it and configure Stim 1 Onset (s) and Stim 2 Onset (s) (for \(N > 2\) the inter-stimulus interval is derived fromstim2_onset_s - stim1_onset_sand applied uniformly)The analysis uses iterative cumulative decay subtraction: each pulse’s bi-exponential (with mono-exponential fallback) decay tail is fitted and evaluated at subsequent response peak timestamps before measuring corrected amplitudes
Results include per-pulse raw and corrected amplitudes (
amplitude_raw_pN,amplitude_corrected_pN), ratios normalised to R1 (ratio_pN), cumulative residuals (residual_pN), and decay time constants (decay_tau_ms_pN)Click “Add to Session” to store for later export
Stimulus Train (STP)
Load a multi-pulse train recording
Switch to the Stimulus Train (STP) sub-tab (
stimulus_train_stp)Enable Detect Stim from TTL (
use_ttl) with TTL Threshold (V) (ttl_threshold), or disable TTL detection and set First Stim Onset (s) (stim_start_s) and Stim Frequency (Hz) (stim_frequency_hz)Configure Number of Pulses (
n_pulses, default 5), Event Polarity (polarity:negativeorpositive), Response Window (ms) (response_window_ms, default20.0 ms), Baseline Window (ms) (baseline_window_ms, default5.0 ms), and Artifact Blanking (ms) (artifact_blanking_ms, default1.0 ms)Results include
pulse_count,r1_amplitude, per-pulse normalised ratios (R2/R1throughRn/R1),amplitudes,amplitudes_norm,pulse_numbers,steady_state_ratio(mean of normalised amplitudes across the lastmin(3, n)pulses whenn >= 2), andstp_type: classified asbiphasicwhenn >= 4and(R2 > R1) != (Rn > R1), otherwisefacilitationwhenR2 > R1ordepressionwhenR2 <= R1Click “Add to Session” to store for later export
Sag Ratio (Ih) Analysis
Load a recording containing a hyperpolarising current-step protocol
Switch to the Sag Ratio (Ih) sub-tab (
sag_ratio_analysis) in the AnalyserConfigure the measurement windows:
Baseline Start / End (s) - resting membrane potential window (before the step)
Peak Window Start / End (s) - early part of the step where the sag minimum occurs
Steady-State Start / End (s) - late part of the step where voltage has plateaued
Adjust Peak Smoothing (ms) to control Savitzky-Golay smoothing of peak and rebound detection (default
5.0 ms). Increase for noisy tracesSet Rebound Window (ms) to control how far after stimulus offset the rebound depolarisation is measured (default
100.0 ms)Results include:
sag_ratio - ratio
(V_ss - V_baseline) / (V_peak - V_baseline)(< 1indicates \(I_h\) sag,1 = no sag)sag_percentage - percentage of sag deflection
100 * (V_peak - V_ss) / (V_peak - V_baseline)v_peak, v_ss, v_baseline - the three voltage levels
rebound_depolarization - post-stimulus rebound amplitude
The plot shows horizontal lines at
v_baseline(blue),v_peak(magenta), andv_ss(red)
Additional Analysis Modules
The following analysis modules are also available in the Analyser tab. All parameters are auto-generated from registry metadata and include tooltips, valid ranges, and conditional visibility based on clamp mode.
Intrinsic Properties tab:
Tau (Time Constant) (
tau_analysis) - Mono- or bi-exponential fit (tau_model:"mono"or"bi") to the membrane charging trajectory after step onset, with automatic sag-peak truncation, configurablemin_r_squaredquality gate (default0.80), 95% confidence bounds, and post-stimulus off-relaxationtau_decay_after_stimulus_ms. A cyan trace overlay highlights the 5 ms baseline window immediately before step onset.I-V Curve (
iv_curve_analysis) - Current-voltage relationship across multi-trial step protocols. Automatically excludes suprathreshold spiking sweeps (\(\max V \ge -15\,\text{mV}\)) from the subthreshold Ohmic regression when at least two subthreshold sweeps exist, computesrectification_index, and opens a popup I-V scatter plot.Capacitance (
capacitance_analysis) - Membrane capacitance from current-clamp or voltage-clamp step protocols. In current-clamp mode, series resistance (\(R_s^{\text{CC}}\),rs_cc_mohm) is estimated from the fast voltage jump at step onset (0.5 msdefault window, extrapolated to \(t = 0\)) and used in the corrected formula \(C_m = \tau / (R_{\text{in}} - R_s)\). In voltage-clamp mode, \(R_s\) (series_resistance_mohm) and \(C_m\) (capacitance_pf, via mono-exponential transient decay fit \(\tau_{\text{trans}} / R_s\) with charge-integral fallback) are extracted from the capacitive transient.
Spike Analysis tab:
Spike Detection (
spike_detection) - Two-stage \(dV/dt\) + voltage threshold spike detector extracting 18 per-spike action potential features (SingleSpikeResult) with sub-sample linear interpolation for half-width and 10-90% rise/decay kinetics.Phase Plane (
phase_plane_analysis) - \(dV/dt\) (Savitzky-Golay smoothed) vs. voltage trajectory for AP initiation dynamics. Bounds each pre-spike search window at the preceding inter-spike trough and detects AP onset viadvdt_thresholdcrossing withkink_slopefallback; opens a popup phase-plane plot.
Excitability tab:
Excitability (F-I Curve) (
excitability_analysis) - Multi-trial rheobase (rheobase_pa), F-I gain (fi_slope,fi_r_squared,fi_p_value,fi_slope_se, truncated at peak firing rate to exclude depolarisation block),max_freq_hz, per-sweepbroadening_indices, and per-sweepadaptation_ratiosdefined as \(\text{ISI}_{\text{last}} / \text{ISI}_{\text{first}}\) (note: the normalised consecutive ISI-differenceadaptation_indexis computed intrain_dynamics). Opens a popup F-I scatter plot. Requires multi-trial recordings.Burst Analysis (
burst_analysis) - Static (max_isi_start,max_isi_end) or dynamic (dynamic_burst,burst_isi_fractionof mean ISI) burst detection; reportsburst_count,spikes_per_burst_avg,burst_duration_avg, andburst_freq_hz.Spike Train Dynamics (
train_dynamics) - ISI regularity and adaptation metrics:mean_isi_s,cv,cv2,lv, normalised consecutive ISI-differenceadaptation_index,first_spike_delay_ms,first_isi_ms, andspike_broadening_index. Opens a popup ISI plot.
Synaptic Events tab:
Event (Amplitude) (
event_detection_threshold) - Adaptive prominence event detector using a20 msdetrended minimum-variance quiescent noise floor (use_quiescent_noise_floor=Trueby default, or MAD when disabled), local pre-event foot baseline, dynamic charge integration, and optional bi-exponential decay kinetics (compute_kinetics).Event (Template) (
event_detection_deconvolution) - Multi-scale matched-filter cross-correlation for miniature synaptic event detection. Supports configurable Kernel Shape (kernel_shape:"bi-exponential"or"mono-exponential", default"bi-exponential"), Tau Rise (ms), Tau Decay (ms), Threshold (SD), Direction, Min Event Distance (ms), and Kernel Multipliers (kernel_multipliers, default"1.0, 2.0, 3.0"). Each unit-peak-normalised kernel is cross-correlated with the baseline-corrected trace and z-scored via MAD; events are detected on the pointwise maximum of the aligned z-score traces to tolerate dendritic cable filtering.
Protocol Maps and Compatible Averaging
Acquisition files do not always include reliable command or stimulus metadata. Before analysing a mixed recording, use Protocol Map… in the Explorer’s Analysis Selection panel to describe the protocol actually used. This is optional: recordings without a map retain the existing whole-trial workflow and are labelled as needing review rather than silently being treated as verified. Neo imports retain ABF command waveforms and pulse onsets from explicitly labelled TTL or stimulation channels as unverified evidence annotations. Any other imported protocol label is descriptive provenance only; it cannot route an analysis or make a recording protocol-compatible.

Select one or more trials and open Protocol Map….
Add a protocol family, such as current step, single stim, paired pulse, stimulus train, or signal only. Trial numbers in this dialog are one-based; ranges such as
1, 3-5are accepted.Optionally limit the assignment to a start/end time range. Analysis segments cannot overlap within a trial; overlapping annotations are allowed as context.
If a Detected evidence item is present, select it to copy the recorded command or TTL timing into the new assignment. Then choose the experimental family. Synaptipy never infers that family from waveform shape alone. Recorded is reserved for this importer-backed evidence. A manual assignment can instead record that a reviewed current-step table or stimulus-timing table was supplied.
Mark the assignment Reviewed only after checking it against the acquisition record. The readiness indicator in the Analyser reports whether the selected analysis is compatible, needs review, or is incompatible.
For batch work, enable Build Compatible Cross-File Averages. Synaptipy first averages selected technical repeats within each file, then averages the per-file traces equally. It keeps different protocol fingerprints separate and records contributors and exclusions in the result provenance. This prevents a current-step segment, paired-pulse segment, or mismatched protocol timeline from being pooled into the same master trace. Analyses that require a multi-trial command relationship (for example an I-V or F-I curve) are still run on their compatible trials rather than inferred from an unrelated pooled trace.
The Protocol Map dialog is exercised in the headless GUI suite by rendering a real Qt dialog capture, so its controls are checked with the pinned PySide6 version as well as documented here.
Visual Validation Overlays
Several analysis sub-tabs draw semi-transparent overlays directly on top of the raw trace to assist with visual validation of the analysis windows and fitted curves. These overlays are rendered entirely in pyqtgraph and do not affect the underlying data.
Overlay type |
Where it appears |
Default colour |
|---|---|---|
Trace overlay |
Pre-stimulus baseline region highlighted on Tau (cyan |
|
Event fit overlay |
Bi-/mono-exponential decay fits on each pulse’s tail in PPR |
Amber ( |
Customising overlay appearance:
Open View > Plot Customization… (or the settings toolbar button).
Switch to the Trace Overlay tab to adjust the highlight colour, line width, and opacity with a slider.
Switch to the Event Fit Overlay tab to adjust the fitted-curve colour, width, and opacity.
All overlay settings are persisted via QSettings and restored across sessions.
Using the Exporter Tab
Exporting to NWB
Load a recording in the Explorer tab
Navigate to the Exporter tab and select the “NWB Export” sub-tab
Specify the output file location
Fill in required MINDS/DANDI metadata:
Session description, identifier, and start time
Subject ID (and species/sex/age)
Device description (and amplifier name/manufacturer)
Click “Export to NWB” and wait for the export to complete
Note
The NWB exporter writes:
Voltage and current traces as
CurrentClampSeries/VoltageClampSeriespre-scaled to SI base units (volts/amperes, includinguVanduA) withconversion=1.0Electrode, device, and required subject metadata, plus structured provenance in
NWBFile.notesrecording acquisition temperature (for \(Q_{10}\) scaling), liquid junction potential (liquid_junction_potential_mv), and digital filter parameters (filter_params)Stimulus waveforms via a 3-step fallback: (1) raw digitized command waveform from the acquisition file; (2) synthetic step (
nEpochType == 1) and linear ramp (nEpochType == 2) command waveforms reconstructed from ABFEpochSectionsmetadata (description notes"Synthetic stimulus array reconstructed from protocol metadata."); (3)stimulus=Nonewith a warning appended to the response trace description when no waveform is availableIntracellularRecordingsTable,SimultaneousRecordingsTable, andSequentialRecordingsTablefor NWB 2.x intracellular sweep grouping/processing/analysis(ProcessingModule) containing thescalar_metricsDynamicTable(channel,analysis,metric,value) and per-channel discrete-eventDynamicTableobjects (time_s,amplitude) from_raw_arrays/processing/preprocessing(ProcessingModule) containing thepreprocessing_stepsDynamicTable(timestamp,operation,parameters)
See NWB Export Mapping for full container mapping details.
Exporting Analysis Results
Navigate to the “Analysis Results” sub-tab in the Exporter tab
Click “Refresh Results” to see all saved analysis results
Select which results to export
Specify the CSV output file location
Click “Export Selected” to create the output:
Exported CSV tables round general floating-point metrics to 6 significant figures while preserving 10 significant figures (
%.10g) for all timestamps, spike/event times, onsets, latencies, delays, and ISIs so sub-millisecond timing across long recordings is never truncated.Every exported CSV writes a companion
<stem>_provenance.jsonrecording the Synaptipy version, UTC timestamp, source files, analysis parameters, and dependency versions.Note: If your exported results contain multiple different types of analysis (e.g. some RMP results and some Spike Detection results), Synaptipy generates a ZIP Archive containing separate CSV files for each unique analysis type, including custom plugin columns.
GraphPad Prism Export
For direct import into GraphPad Prism, use CSVExporter.export_to_prism_format
from the Python API. The method writes a grouped-column CSV where each
column represents one experimental condition and each row is a replicate
observation. Pass aggregate_by_file=True when results contains multiple
sweeps per cell/recording so sweeps from the same source file are averaged into
a single biological-replicate mean per group prior to export, avoiding
sweep-level pseudoreplication. Columns of unequal length are padded with empty
cells so Prism computes group statistics without warnings.
from pathlib import Path
from synaptipy.infrastructure.exporters.csv_exporter import CSVExporter
exporter = CSVExporter()
exporter.export_to_prism_format(
results, # list of result dicts from BatchAnalysisEngine
Path("my_experiment.csv"), # base path; writes my_experiment_prism_rin_mohm.csv
metric="rin_mohm", # scalar metric to export
group_by_key="Condition", # key in each result row that labels the group
aggregate_by_file=True, # average technical sweeps per source file (N = cell/file)
)
The output CSV columns are the unique group labels; each value is rounded to
six significant figures, and a companion <stem>_provenance.json is written
alongside the Prism CSV.
Exporting Plots
Every Explorer and Analyser sub-tab includes a Save Plot button. The export dialog provides three predefined presets for common publication workflows:
Preset |
Format |
Resolution |
Typical use |
|---|---|---|---|
Journal Quality |
PDF (vector) |
300 DPI |
Manuscript figure submission |
Presentation |
PNG (raster) |
150 DPI |
Slide decks and posters |
Web |
PNG (raster) |
72 DPI |
Online supplementary material |
Select Custom to choose format (PNG, JPG, SVG, PDF) and DPI independently. Vector formats (SVG, PDF) retain editable text elements suitable for post-hoc annotation in illustration software, and a JSON provenance sidecar is written next to each exported figure.
Advanced Options
Reproducibility: How GUI Adjustments Serialize to the Batch Engine
A core design goal of Synaptipy is that any parameter adjustment made
interactively in the GUI produces an identical result when replayed by the
headless BatchAnalysisEngine. This section explains the serialization pathway.
Parameter capture
Every widget in an analysis tab (spin-boxes, check-boxes, combo-boxes,
draggable region handles) corresponds to one entry in the tab’s
ui_params list, which is declared alongside the
@AnalysisRegistry.register(...) decorator for that analysis function. The
parameter name, type, and current value are stored together.
When the user clicks Run Analysis, the tab calls
_gather_analysis_parameters(), which iterates over every ui_params entry
and reads the current widget value. The result is a plain Python dictionary:
# Example parameter dict for the Tau analysis tab
params = {
"stim_start_time": 0.200, # s (from a QDoubleSpinBox)
"fit_duration": 0.300, # s
"stim_end_time": 0.600, # s
"tau_model": "mono", # (from a QComboBox)
"artifact_blanking_ms": 0.5,
"min_r_squared": 0.80,
}
Interactive region handles
Draggable baseline or fit windows rendered as pyqtgraph.LinearRegionItem
objects are two-way linked to the corresponding spin-box pair via Qt signals.
Dragging the region emits sigRegionChangeFinished, which updates the
spin-box values. Conversely, typing in a spin-box moves the region.
At the moment of analysis, the spin-box values - not the graphical object
positions - are read into the parameter dictionary. The graphical object is
therefore only a visual convenience; the canonical parameter value is always
the spin-box number.
SessionManager serialization
SessionManager (a singleton) stores:
# Simplified SessionManager state
{
"active_analysis": "tau_analysis",
"preprocessing_settings": {"type": "filter", "method": "lowpass", "cutoff": 2000.0, "order": 5},
"analysis_params": {
"tau_analysis": {
"stim_start_time": 0.200,
"fit_duration": 0.300,
"tau_model": "mono",
},
},
}
These dictionaries are serialized to JSON when the user saves a session file (File > Save Session). Loading a session file restores them, so every tab shows the same parameter values as when the session was saved.
Batch engine replay and preprocessing pipeline
Interactive trace preprocessing in the GUI uses SignalProcessingPipeline
(synaptipy.core.processing_pipeline.SignalProcessingPipeline). For headless
batch replay, synaptipy.core.analysis.preprocessing registers seven
@AnalysisRegistry.register_processor tasks (baseline_subtraction,
lowpass_filter, highpass_filter, bandpass_filter, notch_filter,
comb_filter, and detrend_filter) that invoke the identical DSP primitives in
synaptipy.core.signal_processor. Prepending preprocessing tasks in
pipeline_config transforms each channel’s trace in-order before subsequent
analysis tasks run in BatchAnalysisEngine.run_batch(files, pipeline_config):
from pathlib import Path
from synaptipy.core.analysis.batch_engine import BatchAnalysisEngine
import synaptipy.core.analysis # populates analysis and preprocessing registries
engine = BatchAnalysisEngine(max_workers=1)
pipeline = [
{
"analysis": "baseline_subtraction",
"params": {"method": "region", "start_t": 0.0, "end_t": 0.1},
},
{
"analysis": "lowpass_filter",
"params": {"cutoff": 2000.0, "order": 5, "filter_type": "butterworth"},
},
{
"analysis": "tau_analysis",
"scope": "all_trials",
"params": {
"stim_start_time": 0.200,
"fit_duration": 0.300,
"tau_model": "mono",
"artifact_blanking_ms": 0.5,
"min_r_squared": 0.80,
},
},
]
results_df = engine.run_batch(
files=[Path("cell_01.abf"), Path("cell_02.abf")],
pipeline_config=pipeline,
)
Because both interactive and batch paths execute the same registered DSP primitives and analysis wrappers with identical parameters, the headless batch output matches the GUI result.
Preferences
Open Edit > Preferences to configure application settings across two tabs:
Tab |
Setting |
Description |
|---|---|---|
General |
Scroll Behavior |
Choose |
General |
Appearance |
Switch between |
General |
Extensions ( |
When checked (default), Synaptipy loads Python plugins from |
Performance |
Parallel Processing ( |
Number of worker processes used by |
Performance |
Memory ( |
Target RAM ceiling in GB ( |
Performance |
Rendering ( |
Opt-in OpenGL rendering toggle (disabled by default; requires application restart to take effect). Keep disabled on Linux headless/X11 or unstable GPU drivers. |
Version Checking
The application performs a version check at startup. If a newer release is detected on GitHub Releases, a yellow banner appears below the menu bar displaying the version number and a link to release notes. The banner may be dismissed.
A manual check may be initiated via Help > Check for Updates…. Status bar messages indicate:
“Checking for updates…” - check in progress.
“You are on the latest version.” - no newer release detected.
Yellow banner - newer version available.
The check consists of a single request to the GitHub Releases API
(api.github.com). If the system is offline or behind a firewall, the check
fails silently.
Enable Custom Plugins - Hot-Reload Mechanism
Toggling “Enable Custom Plugins” does not require an application restart. When the checkbox state changes and the dialog is accepted, Synaptipy:
Calls
PluginManager.reload_plugins(). If user plugin code has changed, Synaptipy asks for consent before it re-executes that code.If the setting is now enabled, re-executes every
.pyfile in~/.synaptipy/plugins/(and optional source/bundle examples). Each file’s@AnalysisRegistry.register(...)decorator re-runs and re-populates the registry while built-in analyses remain intact.Calls
AnalyserTab.rebuild_analysis_tabs()to destroy the existing sub-tab widgets and regenerate them from the updated registry - all within the running process.
The net effect is that plugin tabs appear or disappear immediately without reloading the application. A syntax error or import failure in a single plugin is caught and logged; remaining plugins still load normally, and Synaptipy shows one non-blocking summary dialog.
Tip: If you install a new plugin file while Synaptipy is running, open Preferences and toggle “Enable Custom Plugins” off then on to force an immediate reload of all plugins from disk.
Included Example Plugins
Download four ready-to-run example plugins from Help > Download Example
Plugins…. With Enable Custom Plugins active they load automatically from
~/.synaptipy/plugins/:
Plugin file |
Analyser tab label |
What it measures |
|---|---|---|
|
Synaptic Charge (AUC) |
Postsynaptic current charge ( |
|
Opto Latency Jitter |
Trial-to-trial variability in evoked spike or postsynaptic response latency after TTL pulses |
|
miniML Events |
Deep-learning miniature event detection via miniML; reports baseline-subtracted amplitudes ( |
|
Spike Detection (SpikeInterface) |
Bandpass filtering and spike detection via SpikeInterface; requires |
Edit a downloaded copy in ~/.synaptipy/plugins/ to create a personalised
variant without modifying the Synaptipy installation.
Command Line Arguments
Synaptipy installs two console entry points: synaptipy (desktop GUI) and
synaptipy-batch (headless batch CLI).
Desktop GUI (synaptipy)
synaptipy --help # Show help message and exit
synaptipy --version # Print Synaptipy version and exit
synaptipy --dev # Enable development mode with verbose debug logging
synaptipy --verbose # Increase logging verbosity (-v shorthand supported)
synaptipy -v # Shorthand for --verbose
synaptipy --log-dir /path/to/logs # Write log files to a custom directory
synaptipy --log-file custom.log # Use a custom log filename inside the log directory
synaptipy --file /path/to/data.abf # Open a recording file on launch
synaptipy /path/to/data.abf # Positional file path (also opens on launch)
Headless Batch CLI (synaptipy-batch)
synaptipy-batch --version # Print version and exit
synaptipy-batch list-analyses # Print all registered analysis and preprocessing names
# Run a JSON pipeline on one or more recording files:
synaptipy-batch run cell_01.abf cell_02.abf \
--pipeline pipeline.json \
--output results/batch_summary.csv \
--channel Vm_prime \
--max-workers 2 \
--cross-file-average
synaptipy-batch run flags:
<files...>: One or more input recording paths (positional, required).--pipeline <JSON>: Path to a JSON file containing either a non-empty list of task objects or{"pipeline": [...]}(required).--output <CSV>: Destination CSV path; also writes<stem>_provenance.jsonnext to the CSV (required).--channel <CH>: Channel name or ID to include; repeatable (--channel Vm --channel Im).--max-workers <N>: Number of file-level worker processes (default1).--cross-file-average: Pool compatible trials across files before running analyses.
Logging and Debugging
Logs are stored in ~/.synaptipy/logs/ by default. In development mode, logs include detailed information for debugging.
To activate development mode:
# Using command line flag
synaptipy --dev
# Using environment variable
SYNAPTIPY_DEV_MODE=1 synaptipy
Generating Publication-Quality Figures
Synaptipy’s programmatic API is designed for direct use in manuscript
workflows. The code patterns below are used in every example in the
examples/ directory and can be copy-pasted into your own analysis scripts.
Standard rcParams block
Place this block at the top of any script or notebook cell, before creating any figure object. It sets sans-serif typography, 8 pt fonts appropriate for single-column journal figures, and removes the top and right spines:
import matplotlib
matplotlib.rcParams.update({
"font.family": "sans-serif",
"font.sans-serif": ["Arial", "Helvetica", "DejaVu Sans"],
"font.size": 8,
"axes.titlesize": 8,
"axes.labelsize": 8,
"xtick.labelsize": 7,
"ytick.labelsize": 7,
"legend.fontsize": 7,
"axes.spines.top": False,
"axes.spines.right": False,
"axes.linewidth": 0.8,
"xtick.major.width": 0.8,
"ytick.major.width": 0.8,
"lines.linewidth": 0.8,
"figure.dpi": 150, # screen preview
"savefig.dpi": 300, # output files
"pdf.fonttype": 42, # editable text in Illustrator / Inkscape
"ps.fonttype": 42,
})
Figure sizes follow single-column (3.5 in) or double-column (7.0 in) widths typical for Nature, eLife, and Journal of Neuroscience styles:
fig, ax = plt.subplots(figsize=(3.5, 2.5)) # single-column
fig, ax = plt.subplots(figsize=(7.0, 3.0)) # double-column
L-shaped scale bar for electrophysiology traces
Raw electrophysiology traces should omit conventional axes ticks and instead carry an explicit L-shaped scale bar showing the time and amplitude scales. This matches the standard used in most patch-clamp publications.
# Remove axes decorations entirely
for spine in ax.spines.values():
spine.set_visible(False)
ax.set_xticks([])
ax.set_yticks([])
# Draw the L-bar using plot() and text()
# Adjust x0, y0, sb_dx, sb_dy to your data range
sb_x0 = time[-1] - 0.15 # right-aligned, 15 % from right edge
sb_y0 = data.min() + 0.05 * (data.max() - data.min())
sb_dx = 0.100 # 100 ms horizontal arm
sb_dy = 10.0 # 10 mV vertical arm
ax.plot([sb_x0, sb_x0 + sb_dx], [sb_y0, sb_y0],
color="k", linewidth=1.5, solid_capstyle="butt", clip_on=False)
ax.plot([sb_x0, sb_x0], [sb_y0, sb_y0 + sb_dy],
color="k", linewidth=1.5, solid_capstyle="butt", clip_on=False)
ax.text(sb_x0 + sb_dx / 2, sb_y0 - 1.2, "100 ms",
ha="center", va="top", fontsize=7)
ax.text(sb_x0 - 0.01, sb_y0 + sb_dy / 2, "10 mV",
ha="right", va="center", fontsize=7, rotation=90)
Statistical transparency: strip plots instead of bare bar charts
Rather than plotting only the group mean, overlay individual data points with horizontal jitter so reviewers can assess the underlying distribution:
import numpy as np
rng = np.random.default_rng(0)
x_pos = np.arange(len(groups))
fig, ax = plt.subplots(figsize=(3.5, 2.5))
for i, (label, values) in enumerate(groups.items()):
jitter = rng.uniform(-0.15, 0.15, size=len(values))
ax.scatter(x_pos[i] + jitter, values,
s=12, color="#4393c3", alpha=0.7, linewidths=0, zorder=3)
# Mean bar with SEM error bar
means = [np.mean(v) for v in groups.values()]
sems = [np.std(v, ddof=1) / np.sqrt(len(v)) for v in groups.values()]
ax.bar(x_pos, means, width=0.45,
color="#d1e5f0", edgecolor="#4393c3", linewidth=0.8, zorder=2)
ax.errorbar(x_pos, means, yerr=sems, fmt="none",
ecolor="#2166ac", elinewidth=1.0, capsize=2, zorder=4)
ax.set_xticks(x_pos)
ax.set_xticklabels(list(groups.keys()), rotation=40, ha="right")
Saving figures for headless / CI environments
Always save figures to disk and close them explicitly. Never call plt.show()
in batch scripts or CI pipelines - it blocks execution in headless
environments:
plt.savefig("figure_01.pdf", bbox_inches="tight")
plt.savefig("figure_01.png", bbox_inches="tight")
plt.close("all")
The PDF uses pdf.fonttype=42 (set in the rcParams block above), which
embeds fonts as TrueType outlines. This makes text editable in Adobe
Illustrator, Inkscape, and most journal submission portals.
Licensing
Synaptipy is released under the GNU Affero General Public License Version 3 (AGPL-3.0). This license ensures that the software remains free and open source, even when used as a service over a network.
Key aspects of the AGPL-3.0 license:
You are free to use, modify, and distribute the software
If you modify the software, you must release the modified source code
If you use the software to provide a service over a network, you must make the complete source code available to users of that service
Any derivative works must also be licensed under AGPL-3.0
For the full license text, see the LICENSE file in the root of the Synaptipy repository.
Troubleshooting
Common Issues
File Format Not Recognized:
Ensure the file is one of the supported formats
Check if you have the necessary dependencies for that format
Some formats require additional libraries not included by default
GUI Display Issues:
Ensure PySide6 is properly installed (
PySide6==6.7.3)Update your graphics drivers or keep OpenGL disabled in Edit > Preferences > Performance
If running remotely, ensure X forwarding is enabled
Performance Problems with Large Files:
Enable downsampling for visualization
Increase system RAM if possible
Consider splitting very large recordings into smaller files
Export Failures:
Check available disk space
Ensure write permissions for the target directory
For NWB exports, verify all five mandatory MINDS metadata fields (
session_description,identifier,session_start_time,subject_id,device_description) are provided
Biological Troubleshooting
These scenarios describe what analysis outputs mean in terms of patch-clamp physiology, not solely software errors.
“Tau returns NaN after a current step”
A failed exponential fit (or rejection by the min_r_squared quality gate,
default 0.80) typically indicates one of:
The patch is leaky - the cell membrane has not sealed properly (seal resistance below ~1 GOhm), so the voltage decays non-exponentially.
The cell has not reached steady-state - the current step or
fit_durationis too short relative to \(\tau\). Increase the step duration (\(> 5 \times \tau\), typically 200-500 ms for cortical neurons).The fit window includes the stimulus artifact - verify that
artifact_blanking_ms(default0.5 ms) skips the initial fast resistive jump.Access resistance is too high (>30 MOhm for whole-cell) - the series resistance limits current delivery, making the charging trajectory multi-exponential (switch
tau_modelto"bi"or re-patch).
“Input resistance (Rin) is abnormally low (< 50 MOhm for a cortical neuron)”
The holding current is wrong: the cell may be partially clamped at an unphysiological potential. Check your resting Vm before stepping.
Shunt conductance: an imperfect seal or damaged membrane adds parallel conductance that reduces apparent Rin. Check seal resistance.
The step amplitude is too large - nonlinear I-V conductances (\(I_h\), inward rectifier \(\text{K}^+\)) are activated. Use small hyperpolarising steps (5-20 pA).
“Spike threshold is reported as NaN”
calculate_spike_features pre-filters the trace with a 4th-order 9.9 kHz
zero-phase Bessel low-pass filter and searches backward from the peak
\(dV/dt\) in the onset_lookback window (default 0.01 s) for the last sample
below dvdt_threshold (default 20.0 V/s), taking the next sample
(\(\ge \theta_{dV/dt}\)) as action potential onset. ap_threshold is flagged as
NaN when the detected crossing lands at the start boundary of the lookback
window (at_edge, first_crossing_rel_idx == 0) and either:
Peak rising velocity in the lookback window exceeds
DVDT_ARTIFACT_CEILING_VS(> 300 V/s), indicating an unblanked electrical or photoelectric transient, orThe rising phase from threshold to peak is shorter than
MIN_RISING_PHASE_MS(< 0.2 ms), indicating a capacitive artifact or truncated spike onset at the edge of the window.Increase
onset_lookbackif slow pre-potentials push the upstroke beyond the lookback boundary, blank stimulus artifacts before spike detection, or adjustdvdt_thresholdto match your preparation (e.g.10 V/sfor slow-spiking neurons or higher ceilings for 34 degC fast-spiking interneurons).
“Synaptic charge (AUC) is negative or much larger than expected”
Check that the baseline window precedes the stimulus onset and does not overlap spontaneous bursts; local pre-stimulus baselining avoids bias when holding current drifts during long recording epochs.
Verify the integration window does not include the stimulus artifact. Set window start after the stimulus transient.
In voltage-clamp, inward EPSCs are negative (
Charge_pC < 0) by sign convention unless polarity-adjusted.
“Opto-jitter is impossibly short (< 1 ms)”
This almost always means the photo-electric artifact from the LED or laser shutter is being detected as a spike. Set Artifact Blanking (ms) to at least 1-2 ms. Genuine monosynaptic latencies are 2-5 ms for direct ChR2-expressing targets; disynaptic latencies are 8-15 ms.
“Rs QC warning in batch output: Series resistance destabilized”
The Rs warning appears when the series resistance increased by more than 20% (default) compared to the first sweep. This typically means:
The pipette tip clogged partially during the recording.
The gigaohm seal broke down gradually. Sweeps flagged with
rs_qc_warningshould be excluded from analysis. The default threshold (20%) can be adjusted via thers_toleranceparameter inBatchAnalysisEngine.run_batch().
Analysis Parameter Reference
The table below explains common parameters in biological terms so you can choose values that match your experimental design.
Parameter |
Unit |
Biological meaning |
Typical range |
|---|---|---|---|
|
mV or pA |
Minimum height of an event above the local baseline. Prevents noise peaks from being counted as real spikes or synaptic events. |
5-30 mV (spikes); 5-50 pA (PSCs) |
|
ms |
Minimum duration of an event at half-maximum. Excludes electrical transients narrower than biological APs (0.5-2 ms) or PSCs (2-20 ms). |
0.3-1.0 ms (spikes); 2-10 ms (PSCs) |
|
mV or pA |
Voltage (or current) level a trace must reach to be accepted as an event. Set slightly above the noise floor. |
-20 mV (spikes); 3 x noise RMS (PSCs) |
|
s or ms |
Minimum inter-event interval. Prevents double-counting the same AP or PSC. Should be slightly shorter than the fastest physiological inter-event interval in your data. |
2-5 ms (spikes); 5-20 ms (PSCs) |
|
ms or s |
Duration of the pre-event window used to measure the resting level. Shorter windows (5-10 ms) track slow holding-current drift more accurately than long windows. |
5-20 ms |
|
s |
How far before each spike peak to search backward from max \(dV/dt\) for the AP onset crossing. Should span the full AP upstroke plus margin. |
0.002-0.010 s (2-10 ms) |
|
ms |
Width of the Savitzky-Golay smoothing window applied to \(dV/dt\) in phase-plane analysis. Increase for noisy recordings; set to |
0.1-0.5 ms |
|
s |
Onset time of the current or voltage command step. |
Protocol-dependent |
|
mV |
Amplitude of the VC command step, required for \(R_s\) and \(C_m\) calculation. Use the command amplitude rather than the measured response. |
-10 to -5 mV (typical access resistance protocol) |
|
ms |
Duration after a stimulus onset excluded from peak or fit evaluation so shock or photo-electric artifacts are not misclassified as responses. |
0.5-2.0 ms |
|
fraction |
Maximum fractional increase in series resistance before a sweep is flagged as unstable ( |
0.10-0.30 |
Getting Help
If you encounter issues not covered here:
Check the GitHub Issues for known problems
Create a new issue with details about your problem
Include the log files and error messages in your report