GetTCFrictionIsolator

GetTCFrictionIsolator

Syntax

SapObject.SapModel.PropLink.GetTCFrictionIsolator

VB6 Procedure

Function GetTCFrictionIsolator(ByVal Name As String, ByRef DOF() As Boolean, ByRef Fixed() As Boolean, ByRef NonLinear() As Boolean, ByRef Ke() As Double, ByRef Ce() As Double, ByRef k() As Double, ByRef Slow() As Double, ByRef Fast() As Double, ByRef Rate() As Double, ByRef Radius() As Double, ByRef SlowT() As Double, ByRef FastT() As Double, ByRef RateT() As Double, ByRef kt As Double, ByRef dis As Double, ByRef dist As Double, ByRef Damping As Double, ByRef dj2 As Double, ByRef dj3 As Double, ByRef Notes As String, ByRef GUID As String) As Long

Parameters

Name

The name of an existing T/C friction isolator-type link property.

DOF

This is a boolean array, dimensioned to 5, indicating if properties exist for a specified degree of freedom.

DOF(0) = U1

DOF(1) = U2

DOF(2) = U3

DOF(3) = R1

DOF(4) = R2

DOF(5) = R3

Fixed

This is a boolean array, dimensioned to 5, indicating if the specified degree of freedom is fixed (restrained).

Fixed(0) = U1 fixity

Fixed(1) = U2 fixity

Fixed(2) = U3 fixity

Fixed(3) = R1 fixity

Fixed(4) = R2 fixity

Fixed(5) = R3 fixity

The term Fixed(n) applies pnly when DOF(n) = True.

NonLinear

This is a boolean array, dimensioned to 5, indicating if nonlinear properties exist for a specified degree of freedom.

NonLinear(0) = U1 has nonlinear properties

NonLinear(1) = U2 has nonlinear properties

NonLinear(2) = U3 has nonlinear properties

NonLinear(3) = R1, Not Used

NonLinear(4) = R2, Not Used

NonLinear(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U1, U2 and U3. For those degrees of freedom, the term NonLinear(n) applies only when DOF(n) = True and Fixed(n) = False.

Ke

This is an array of effective stiffness terms for the link property. The effective stiffness applies for linear analyses.

Ke(0) = U1 [F/L]

Ke(1) = U2 [F/L]

Ke(2) = U3 [F/L]

Ke(3) = R1 [FL]

Ke(4) = R2 [FL]

Ke(5) = R3 [FL]

The term Ke(n) applies only when DOF(n) = True and Fixed(n) = False.

Ce

This is an array of effective damping terms for the link property. The effective damping applies for linear analyses.

Ce(0) = U1 [F/L]

Ce(1) = U2 [F/L]

Ce(2) = U3 [F/L]

Ce(3) = R1 [FL]

Ce(4) = R2 [FL]

Ce(5) = R3 [FL]

The term Ce(n) applies only when DOF(n) = True and Fixed(n) = False.

k

This is an array of initial stiffness terms for the link property. The initial stiffness applies for nonlinear analyses.

k(0) = U1 [F/L]

k(1) = U2 [F/L]

k(2) = U3 [F/L]

k(3) = R1, Not Used

k(4) = R2, Not Used

k(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U1, U2 and U3. For those degrees of freedom, the term k(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

Slow

This is an array of the friction coefficient at zero velocity terms when U1 is in compression for the link property. This coefficient applies for nonlinear analyses.

Slow(0) = U1, Not Used

Slow(1) = U2

Slow(2) = U3

Slow(3) = R1, Not Used

Slow(4) = R2, Not Used

Slow(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term Slow(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

Fast

This is an array of the friction coefficient at fast velocity terms when U1 is in compression for the link property. This coefficient applies for nonlinear analyses.

Fast(0) = U1, Not Used

Fast(1) = U2

Fast(2) = U3

Fast(3) = R1, Not Used

Fast(4) = R2, Not Used

Fast(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term Fast(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

Rate

This is an array of the inverse of the characteristic sliding velocity terms when U1 is in compression for the link property. This item applies for nonlinear analyses.

Rate(0) = U1, Not Used

Rate(1) = U2 [s/L]

Rate(2) = U3 [s/L]

Rate(3) = R1, Not Used

Rate(4) = R2, Not Used

Rate(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term Rate(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

Radius

This is an array of the radius of the sliding contact surface terms for the link property. Inputting 0 means there is an infinite radius, that is, the slider is flat. This item applies for nonlinear analyses.

Radius(0) = U1, Not Used

Radius(1) = U2 [L]

Radius(2) = U3 [L]

Radius(3) = R1, Not Used

Radius(4) = R2, Not Used

Radius(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term Radius(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

SlowT

This is an array of the friction coefficient at zero velocity terms when U1 is in tension for the link property. This coefficient applies for nonlinear analyses.

SlowT(0) = U1, Not Used

SlowT(1) = U2

SlowT(2) = U3

SlowT(3) = R1, Not Used

SlowT(4) = R2, Not Used

SlowT(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term SlowT(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

FastT

This is an array of the friction coefficient at fast velocity terms when U1 is in tension for the link property. This coefficient applies for nonlinear analyses.

FastT(0) = U1, Not Used

FastT(1) = U2

FastT(2) = U3

FastT(3) = R1, Not Used

FastT(4) = R2, Not Used

FastT(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term FastT(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

RateT

This is an array of the inverse of the characteristic sliding velocity terms when U1 is in tension for the link property. This item applies for nonlinear analyses.

RateT(0) = U1, Not Used

RateT(1) = U2 [s/L]

RateT(2) = U3 [s/L]

RateT(3) = R1, Not Used

RateT(4) = R2, Not Used

RateT(5) = R3, Not Used

Note that this item is applicable only for degrees of freedom U2 and U3. For those degrees of freedom, the term RateT(n) applies only when DOF(n) = True, Fixed(n) = False and NonLinear(n) = True.

kt

The axial translational tension stiffness for the U1 degree of freedom. This item applies for nonlinear analyses. [F/L]

dis

The U1 degree of freedom gap opening for compression. This item applies for nonlinear analyses. [L]

dist

The U1 degree of freedom gap opening for tension. This item applies for nonlinear analyses. [L]

Damping

The nonlinear damping coefficient used for the axial translational degree of freedom, U1. This item applies for nonlinear analyses. [F/L]

dj2

The distance from the J-End of the link to the U2 shear spring. This item applies only when DOF(1) = True. [L]

dj3

The distance from the J-End of the link to the U3 shear spring. This item applies only when DOF(2) = True. [L]

Notes

The notes, if any, assigned to the property.

GUID

The GUID (global unique identifier), if any, assigned to the property.

Remarks

This function retrieves link property data for a T/C friction isolator-type link property.

The function returns zero if the property data is successfully retrieved; otherwise it returns a nonzero value.

VBA Example

Sub GetLinkPropTCFrictionIsolator()

'dimension variables

Dim SapObject as cOAPI

Dim SapModel As cSapModel

Dim ret As Long

Dim MyDOF() As Boolean

Dim MyFixed() As Boolean

Dim MyNonLinear() As Boolean

Dim MyKe() As Double

Dim MyCe() As Double

Dim MyK() As Double

Dim MySlow() As Double

Dim MyFast() As Double

Dim MyRate() As Double

Dim MyRadius() As Double

Dim MySlowT() As Double

Dim MyFastT() As Double

Dim MyRateT() As Double

Dim DOF() As Boolean

Dim Fixed() As Boolean

Dim Nonlinear() As Boolean

Dim Ke() As Double

Dim Ce() As Double

Dim k() As Double

Dim Slow() As Double

Dim Fast() As Double

Dim Rate() As Double

Dim Radius() As Double

Dim SlowT() As Double

Dim FastT() As Double

Dim RateT() As Double

Dim kt As Double

Dim dis As Double

Dim dist As Double

Dim Damping As Double

Dim dj2 As Double

Dim dj3 As Double

Dim Notes As String

Dim GUID As String

'create Sap2000 object

Set SapObject = CreateObject("CSI.SAP2000.API.SapObject")

'start Sap2000 application

SapObject.ApplicationStart

'create SapModel object

Set SapModel = SapObject.SapModel

'initialize model

ret = SapModel.InitializeNewModel

'create model from template

ret = SapModel.File.New2DFrame(PortalFrame, 2, 144, 2, 288)

'add link property

ReDim MyDOF(5)

ReDim MyFixed(5)

ReDim MyNonLinear(5)

ReDim MyKe(5)

ReDim MyCe(5)

ReDim MyK(5)

ReDim MySlow(5)

ReDim MyFast(5)

ReDim MyRate(5)

ReDim MyRadius(5)

ReDim MySlowT(5)

ReDim MyFastT(5)

ReDim MyRateT(5)

MyDOF(0) = True

MyNonLinear(0) = True

MyKe(0) = 12

MyCe(0) = 0.01

MyK(0) = 1000

MyDOF(1) = True

MyNonLinear(1) = True

MyKe(1) = 12

MyCe(1) = 0.01

MyK(1) = 20

MySlow(1)= 0.6

MyFast(1)= 0.5

MyRate(1)= 10

MyRadius(1)= 80

MySlowT(1)= 0.61

MyFastT(1)= 0.51

MyRateT(1)= 10.1

MyDOF(2) = True

MyNonLinear(2) = True

MyKe(2) = 14

MyCe(2) = 0.008

MyK(2) = 22

MySlow(2)= 0.66

MyFast(2)= 0.55

MyRate(2)= 12

MyRadius(2)= 75

MySlowT(2)= 0.67

MyFastT(2)= 0.56

MyRateT(2)= 12.1

MyDOF(3) = True

MyKe(3) = 15

MyCe(3) = 0

MyDOF(4) = True

MyFixed(4) = True

ret = SapModel.PropLink.SetTCFrictionIsolator("TCFI1", MyDOF, MyFixed, MyNonLinear, MyKe, MyCe, MyK, MySlow, MyFast, MyRate, MyRadius, MySlowT, MyFastT, MyRateT, 18, 2, 3, 0.1, 2, 3)

'get link property data

ret = SapModel.PropLink.GetTCFrictionIsolator("TCFI1", DOF, Fixed, NonLinear, Ke, Ce, k, Slow, Fast, Rate, Radius, SlowT, FastT, RateT, kt, dis, dist, Damping, dj2, dj3, Notes, GUID)

'close Sap2000

SapObject.ApplicationExit False

Set SapModel = Nothing

Set SapObject = Nothing

End Sub

Release Notes

Initial release in version 11.02.

See Also