EMC COMPLIANCE TEST REPORT
================================================================================
Generated by Oscura Framework
Standard: CISPR 32:2015 Class B

CONDUCTED EMISSIONS (CISPR 32 Class B)
--------------------------------------
Frequency Range: 150 kHz - 30 MHz
Measurement Method: CISPR 16-1-1 Quasi-Peak Detector

    0.15 MHz:  -89.3 dBμV (Limit: 66 dBμV) Margin: +155.3 dB [PASS]
    0.50 MHz:   52.0 dBμV (Limit: 56 dBμV) Margin: +4.0 dB [PASS]
    5.00 MHz:  -74.7 dBμV (Limit: 56 dBμV) Margin: +130.7 dB [PASS]
   30.00 MHz:  -82.1 dBμV (Limit: 60 dBμV) Margin: +142.1 dB [PASS]

RADIATED EMISSIONS (CISPR 32 Class B)
-------------------------------------
Frequency Range: 30 MHz - 1 GHz
Measurement Distance: 10 meters
Measurement Method: CISPR 16-1-1 Quasi-Peak Detector

      30 MHz: -100.0 dBμV/m (Limit: 30 dBμV/m) Margin: +130.0 dB [PASS]
     230 MHz:  -92.0 dBμV/m (Limit: 37 dBμV/m) Margin: +129.0 dB [PASS]
    1000 MHz:  -92.6 dBμV/m (Limit: 37 dBμV/m) Margin: +129.6 dB [PASS]

MARGIN ANALYSIS
---------------
Conducted Emissions:
  Worst Case Margin: +4.0 dB
  Best Case Margin:  +155.3 dB

Radiated Emissions:
  Worst Case Margin: +129.0 dB
  Best Case Margin:  +130.0 dB

OVERALL COMPLIANCE STATUS
-------------------------
RESULT: COMPLIANT
All emission measurements are within CISPR 32 Class B limits.

================================================================================
End of Report