PRODUCTION TEST REPORT
================================================================================
Unit ID: DUT-002
Test Date: 2024-01-22 15:30:00
Operator: AUTO
Station: TEST-01

TEST RESULTS
------------
amplitude      :    6.097 V    [   4.5 -    5.5] [FAIL]
frequency      : 1001.992 kHz  [ 999.0 - 1001.0] [FAIL]
rise_time      :   56.942 ns   [   5.0 -  100.0] [PASS]
fall_time      :   62.636 ns   [   5.0 -  100.0] [PASS]
duty_cycle     :   49.322 %    [  48.0 -   52.0] [PASS]
overshoot      :    0.000 %    [   0.0 -   10.0] [PASS]

OVERALL RESULT
--------------
Status: FAIL

Unit FAILED one or more test requirements.
Unit must be reworked or scrapped.

Failed tests:
  - amplitude: 6.097 V
  - frequency: 1001.992 kHz

================================================================================
Signature: __________________    Date: __________