Metadata-Version: 2.4
Name: iaiops-energy
Version: 0.1.12
Summary: Energy edition (变电/电力) for Industrial-AIOps — IEC-104 / DNP3 / IEC-61850 read-only connectors on top of iaiops.core.
Project-URL: Homepage, https://github.com/industrial-aiops/industrial-aiops-energy
Project-URL: Base package, https://github.com/industrial-aiops/industrial-aiops
Author-email: wei <zhouwei008@gmail.com>
License-Expression: MIT
License-File: LICENSE
Keywords: AIOps,DNP3,IEC-104,IEC-61850,OT,SCADA,edge,edge-computing,edge-interoperability,energy,iiot,margo,substation
Requires-Python: >=3.11
Requires-Dist: iaiops<1.0,>=0.22.0
Provides-Extra: dev
Requires-Dist: bandit>=1.7; extra == 'dev'
Requires-Dist: pytest>=8; extra == 'dev'
Requires-Dist: ruff>=0.6; extra == 'dev'
Provides-Extra: dnp3
Requires-Dist: pydnp3<1,>=0.1; extra == 'dnp3'
Provides-Extra: energy
Requires-Dist: c104<3,>=2.0; extra == 'energy'
Requires-Dist: pydnp3<1,>=0.1; extra == 'energy'
Requires-Dist: pyiec61850<2,>=1.5.2a1; (platform_system == 'Linux') and extra == 'energy'
Provides-Extra: iec104
Requires-Dist: c104<3,>=2.0; extra == 'iec104'
Provides-Extra: iec61850
Requires-Dist: pyiec61850<2,>=1.5.2a1; (platform_system == 'Linux') and extra == 'iec61850'
Description-Content-Type: text/markdown

<!-- mcp-name: io.github.industrial-aiops/iaiops-energy -->

# industrial-aiops-energy — Energy Edition (Substation / Utility)

**English** · [中文](README.zh-CN.md)

The **energy edition** of [Industrial-AIOps](https://github.com/industrial-aiops/industrial-aiops),
split out into its own repo: read-only OT connectors for **substation / utility
telecontrol** protocols, built **on top of `iaiops.core`**.

- **IEC 60870-5-104** (`c104`) — RTU / substation telemetry
- **DNP3 / IEEE 1815** (`pydnp3`) — outstation monitoring
- **IEC 61850 MMS** (`pyiec61850`, linux-only wheel) — substation IED reads

It reuses the base package's shared **governance** (audit / budget / risk-tier /
undo), **cross-protocol brain** (data-flow / alarm / OEE / downtime RCA on the
normalized ISA-95/18.2 model), and MCP server infrastructure — this repo only adds
the three energy connectors + their session builders + MCP tools. Read-first: no
control-direction writes are exposed.

Current release: **0.1.11** (requires `iaiops>=0.20.3,<1.0`). New in 0.1.11 — **all three
monitor paths are CI-gated for the first time**, and a skipped live test now fails the build
instead of passing it. DNP3 was the holdout: `pip install pydnp3` fails on any current Linux,
so this repo inherited the ecosystem's "unbuildable on hosted runners" and
`tests/test_dnp3_live.py` skipped on every build. It is not unbuildable — opendnp3 compiles
clean, and the 2019 binding layer needed three mechanical fixes, now scripted in
`scripts/build_pydnp3.sh` and running on real GitHub runners. Also inherits two governance
fixes from `iaiops` 0.20.3 (pin raised): a call that **failed** is no longer audited as a
success (which also mis-informed the pattern circuit breaker on every failure), and the
runaway guard can now see a caller retrying a denial forever. Previously in 0.1.10 — a **security
fix inherited from the base package**: three egress tools this edition mirrors
(`stream_publish`, `stream_publish_event`, `historian_push`) wrote their credential — a NATS
auth token, a TSDB password — into the audit log in the clear, and `audit_forward` shipped
that row to the configured SIEM. They are defined in `iaiops`, so this edition could not fix
it alone; the pin moves to `iaiops>=0.20.2`, and a contract test now fails the build if the
whole registered surface ever again carries an undeclared credential parameter. **If you have
passed a token or historian password to these tools, rotate it** and check existing audit
rows. The energy connectors themselves take no credential parameters. Previously in 0.1.9 — every tool
ships the MCP `ToolAnnotations` hints (`readOnlyHint` / `destructiveHint` / `openWorldHint`),
**derived** from the `@governed_tool` harness rather than hand-written, so a client can tell a
monitor read from a tool that acts without parsing the `[READ]`/`[WRITE]` docstring tag. On the
wire that is 59 tools, 55 read-only and **0 destructive** — this edition exposes no control
direction, and that is now enforced by a test rather than only documented. They are hints, not a
gate: the MCP spec forbids relying on annotations for security decisions, and enforcement stays in
`@governed_tool`. The base pin moved to `iaiops>=0.20.1` so the hint derivation is imported from
`mcp_server.hints` instead of duplicated here.

Previously in 0.1.8 — the base
`IAIOPS_READ_ONLY` gate was **removed** in iaiops 0.19.0 (read/write authorisation is the
caller's decision — agent judgement / account management — not the tap's; every tool is
governed and audited via the base `@governed_tool` harness), so this edition drops it too.
It keeps the **`IAIOPS_NO_EGRESS=1`** gate — a data-exfiltration / airgap axis that withholds
data-shipping tools from `list_tools()` at registration time. This edition runs its own
`FastMCP` instance, so the gate is wired into its own `main()`; without it `IAIOPS_NO_EGRESS=1`
would still expose `historian_push`, `rca_narrate` and the `stream_publish*` pair mirrored in
from the base brain. The energy connectors themselves are monitor-only and survive the gate
intact. See `CHANGELOG.md`.

Previously in 0.1.6 — an
**audit-hardening pass** over the three read-only connectors: DNP3 no longer reports an
offline outstation as online or returns a partial integrity-poll database; IEC-61850 gained
a bounded connect/request timeout and stopped fabricating `0.0`/empty-success on failure; the
substation analyzer no longer calls a lone breaker-open a "selective trip"; tests isolate
`IAIOPS_HOME`; and the base pin was raised to `iaiops>=0.14` so the governance endpoint-scoping
fix applies. See `CHANGELOG.md` §0.1.6. (0.1.5 verified the IEC-104 monitor path — a real `c104`
client↔server round-trip in a Linux container, `tests/test_iec104_live.py`.)
**Physical RTU / IED remains unverified.** Since 0.1.3 the server has
its **own MCP identity** — `iaiops-energy-mcp` runs a dedicated `FastMCP("iaiops-energy")`
instance with energy-specific instructions (IEC-104 / DNP3 / IEC-61850, read-first,
no control/operate), with the base cross-protocol brain tools mirrored onto it — plus
an **edition skill** (`skills/iaiops-energy/SKILL.md`, anti-drift-tested against the
registered tool surface) and **protocol-consistency contract tests** (every tool must
carry the governance marker, a `[READ]`-style risk tag, an `Args:` section, and the
canonical `{error, hint}` error shape; the server refuses to start if any registered
tool lacks the governance marker).

## 🧪 Beta testing & co-creation

**Live substation RTU / IED / IEC-104 field testing is what this package needs most.**
The IEC-104, DNP3 and IEC-61850 monitor paths are library-loopback-verified, and **all three
now run on every CI build** — a skip fails the build rather than passing it. (Since
2026-08-01: DNP3's evidence used to be a single manual run on 2026-07-02, because `pydnp3`
was believed unbuildable on hosted runners. That belief was wrong — see
`scripts/build_pydnp3.sh`.) **Real RTU / IED hardware remains unverified.** If you can run
`iaiops doctor` against real substation gear in an authorised test environment, we would
very much like to hear the result — verified devices are credited by name in the support
matrix. Report results (protocol + device model + `iaiops doctor` output) via the base
repo's pinned issue:
👉 [industrial-aiops#28 — Call for field-testing partners (v0.10.0)](https://github.com/industrial-aiops/industrial-aiops/issues/28)

## Why a separate repo

Energy targets a distinct buyer (utilities / substations), has heavier
platform-specific deps (`pyiec61850` is a linux-only SWIG wheel; `pydnp3` builds a
native ext), and its own compliance surface (China's *Security Protection of Power
Monitoring Systems* regime). Splitting keeps
the base install light. See the base repo's `docs/ENERGY-SPINOUT.md` for the plan.

## Install

```bash
pip install iaiops-energy[energy]      # all three energy protocols
pip install iaiops-energy[iec104]      # just IEC-104
```

`iaiops-energy` pulls in `iaiops` (the shared core) automatically.

## Use (MCP)

```bash
iaiops-energy-mcp                       # brain + energy tools over stdio
```

Point a target at your substation gear in `~/.iaiops/config.yaml`
(`protocol: iec104|dnp3|iec61850`, `host`, `port`, `common_address` / `unit_id`).

## Edge deployment & ecosystem (edge-native / Margo)

Like the base package, the energy edition rides on a hardened, centrally-managed **edge host** as a
portable, governed **edge application** — mapping onto the [Margo](https://margo.org/)
edge-interoperability roles (immutable host · compliant orchestrator · **iaiops-energy = the
OT-domain app**), deployable as an OCI **Managed Container** (outbound-only to substation RTUs/IEDs,
no inbound). A container + `margo.org/v1-alpha1` application-description skeleton is in
[`deploy/margo/`](deploy/margo/); the full alignment + honest gap analysis lives in the base repo's
[`docs/MARGO-ALIGNMENT.md`](https://github.com/industrial-aiops/industrial-aiops/blob/main/docs/MARGO-ALIGNMENT.md).
The descriptor is validated against Margo's published `margo.org/v1-alpha1` LinkML schema on every
PR (CI job `margo-descriptor`) and passes clean — structural validity only, see
[`deploy/margo/schema/PROVENANCE.md`](deploy/margo/schema/PROVENANCE.md).

> **Honest status:** a natural Margo edge application, but **NOT Margo-compliant yet** — image build,
> hosted+signed package, and a published conformance result are roadmap `⏳`. No claim of compliance
> until that result exists, and the schema pass above is **not** a step toward it: the compliance
> test suite cannot be run today because it does not exist yet (no conformance repo in the `margo`
> org; a first PR1 vertical slice was still being scoped as of 2026-01-15).

## Validation status (honest)

The same honesty ladder as the base repo. Driver **codec / API surface** is verified
against the real libraries; the mock/monkeypatched **unit tests run in CI** without
hardware. See the base repo's `docs/PREVIEW-VERIFICATION.md` runbook for how a
protocol is promoted.

| Protocol | Status | CI coverage | Evidence |
| --- | --- | --- | --- |
| **DNP3 / IEEE 1815** | **verified (monitor path)** | ✅ runs every push ¹ | Real master↔outstation round-trip against a live **opendnp3** outstation (`pydnp3`): `is_online()` reflects the real channel `OnStateChange`, and `integrity_poll()` (Class 0/1/2/3) returns the seeded binary/analog/counter database grouped by type. See `tests/test_dnp3_live.py` (`@pytest.mark.integration`). No physical RTU. |
| **IEC 60870-5-104** | **verified (monitor path)** | ✅ runs every push | Real client↔server round-trip against an in-process **`c104`** server (`tests/test_iec104_live.py` + `tests/iec104_server_harness.py`, `@pytest.mark.integration`, passes in a Linux container): `iec104_connection_info` discovers the seeded station, `iec104_interrogate` (general interrogation / C_IC) returns the seeded `M_ME_NC_1` + `M_SP_NA_1` points with quality, `iec104_read_point` reads the measurand, a bad IOA yields `found=False` with **no fabricated value**, and server-side ASDU capture proves **no control ASDU** (C_SC / C_DC / C_SE) is ever issued. `c104` ships no macOS wheel so the test skips on macOS (runs in CI / Linux). No physical RTU. Monitor/read only. |
| **IEC 61850 (MMS)** | **verified (monitor path)** | ✅ runs every push | Real client↔server MMS round-trip against an in-process **libiec61850** MMS server built with `pyiec61850`'s server API: `iec61850_device_directory` lists the logical device (and browses its logical nodes / data objects), and `iec61850_read` returns a seeded measurand (`TotW.mag.f`, FC `MX`) over real ISO-on-TCP; a bad reference surfaces an MMS data-access error instead of a fabricated value. See `tests/test_iec61850_live.py` (`@pytest.mark.integration`, skips when `pyiec61850` / its server API is absent). No physical IED. Read/monitor only — control / GOOSE / SV out of scope. |

**¹ All three monitor paths are now CI-gated**, and a skip fails the build rather than
passing it (`no live protocol test may skip`). This used to read: *"only IEC-104 is
CI-gated; DNP3 and IEC-61850 rest on out-of-CI runs, not on the green badge."* That was
true and is no longer.

DNP3 was the last one, and the reason is worth recording because the old note here — and
the CI job, and this README — all repeated the same wrong conclusion for months:
`pip install pydnp3` fails on any current Linux, so it was taken as **unbuildable** on
hosted runners. It is not. opendnp3 itself compiles clean; what had rotted was the 2019
binding layer. Three mechanical fixes, no patches to opendnp3:

1. Python headers must be present (`python3-dev`) — without them the build dies at
   `Python.h: No such file or directory`, which is what "unbuildable" looked like;
2. 214 vendored headers `#include <python2.7/Python.h>`, rewritten to `<Python.h>`;
3. the vendored pybind11 predates CPython 3.11 (it reads `PyFrameObject` internals that
   3.11 made opaque) and GCC 13 (`std::uint16_t` without `<cstdint>`) — replaced with
   pybind11 v2.13.6.

`scripts/build_pydnp3.sh` applies all three and verifies the import. ~3 min cold on two
cores. The lesson generalises: *"the ecosystem says it cannot be built"* is a claim to
test, not to inherit.

DNP3 notes: read-only / monitor direction only (no control). Its
`DNP3Manager.Shutdown()` can block in a long-lived interpreter, so the connector bounds
teardown (`_Pydnp3MasterAdapter.shutdown`) and the test drives the round-trip in a
short-lived child process.

## License

MIT — © wei. Part of the vendor-neutral, governed Industrial-AIOps line.