Firmware r1.7.0
===============

Upgrading from (firmware < 1.7.0) to (firmware >= 1.7.0) requires an upgrade to
the SPI-flash bootloader. If you have been sent one of "Flat Mark" or
"Flat Stanley", here are the necessary steps:

1. Remove the MicroSD card from the CRS and turn it on.

2. Set up a keyboard, mouse, and monitor for the portable computer and log in.
   There is no password for this computer.

3. There is a script called "UPGRADE_BOOTLOADER" on the Desktop. Double click
   the desktop icon and follow the prompts. If you wish to do these steps
   manually, proceed to step 4, otherwise skip to step 7.

4. The rfmux repository has already been cloned with the necessary firmware
   files unpacked. Open a terminal and navigate to the r1.7.0 firmware release
   directory with:

	$ cd ~/rfmux/firmware/r1.7.0

5. Set up the Vitis execution environment:

	$ source /opt/xilinx/2025.2/Vitis/settings64.sh

6. Connect the CRS to the portable computer with a micro USB cable and run:

	$ program_flash -f boot.bin -fsbl fsbl.elf -flash_type qspi-x8-dual_parallel

7. The program_flash command should finish with "Flash Operation Successful".
   Once you see this message, power cycle the CRS. The screen on the front panel
   should turn on after a few seconds with the t0.technology logo. You may now
   proceed to flashing firmware version 1.7.0 to your MicroSD card. See
   rfmux/docs/guides/firmware.md for details.

Tip: although not strictly necessary, it can be helpful to see what the CRS is
doing while booting. On the portable computer, open a new terminal before
powering on the CRS and run:

	$ screen /dev/ttyUSB1 115200

Once you power on the CRS, you will start to see its output as it is booting.
To exit screen, press "Ctrl-a" then "d".