Metadata-Version: 2.4
Name: pydaikin
Version: 2.23.0
Summary: Python Daikin HVAC appliances interface
Author-email: Fredrik Erlandsson <fredrik.e@gmail.com>, Yari Adan <mustang@yadan.org>
Maintainer-email: Fredrik Erlandsson <fredrik.e@gmail.com>, Matthias Lemainque <matthias.lemainque+pydaikin@gmail.com>
License-Expression: GPL-3.0-or-later
Project-URL: Homepage, https://github.com/fredrike/pydaikin
Project-URL: Repository, https://github.com/fredrike/pydaikin.git
Project-URL: Issues, https://github.com/fredrike/pydaikin/issues
Classifier: Programming Language :: Python :: 3
Classifier: Operating System :: OS Independent
Classifier: Topic :: Software Development :: Libraries :: Application Frameworks
Classifier: Topic :: Home Automation
Requires-Python: >=3.12
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: psutil
Requires-Dist: aiohttp
Requires-Dist: urllib3
Requires-Dist: tenacity
Dynamic: license-file

![PyPI - License](https://img.shields.io/pypi/l/pydaikin?color=green)
![PyPI - Downloads](https://img.shields.io/pypi/dw/pydaikin?label=downloads&logo=pypi&logoColor=white)
![PyPI - Version](https://img.shields.io/pypi/v/pydaikin?label=version&logo=pypi&logoColor=white)

[![Test Python package](https://github.com/fredrike/pydaikin/actions/workflows/pytest.yml/badge.svg)](https://github.com/fredrike/pydaikin/actions/workflows/pytest.yml)
[![Pylint](https://github.com/fredrike/pydaikin/actions/workflows/pylint.yml/badge.svg)](https://github.com/fredrike/pydaikin/actions/workflows/pylint.yml)
[![codecov](https://codecov.io/github/fredrike/pydaikin/graph/badge.svg?token=DFEYF4L0J2)](https://codecov.io/github/fredrike/pydaikin)
![GitHub Pull Requests](https://img.shields.io/github/issues-pr/fredrike/pydaikin?logo=github)
![GitHub Issues](https://img.shields.io/github/issues/fredrike/pydaikin?logo=github)

# PyDaikin

PyDaikin is a Python library for controlling Daikin air conditioners. It provides both a standalone command-line interface and a Python API for integrating Daikin AC control into your applications.

## Supported Devices

The following Daikin WiFi modules are currently supported:

* **BRP069Axx/BRP069Bxx/BRP069B4x/BRP072Axx** - Standard WiFi adapters
* **BRP15B61 (AirBase)** - Uses a similar protocol to BRP069Axx
* **BRP072B/Cxx** - Requires HTTPS access and an authentication key
* **BRP084** - Devices with firmware version 2.8.0 (uses a different API structure)
* **SKYFi** - Uses a different protocol and requires a password

## Quick Start

Here's a simple example for connecting to a Daikin air conditioner:

```python
import asyncio
import logging

import aiohttp
from pydaikin.daikin_base import Appliance
from pydaikin.factory import DaikinFactory

HOST = "10.1.1.21"

logging.basicConfig(level=logging.INFO)
_LOGGER = logging.getLogger(__name__)


async def main():
    async with await DaikinFactory(HOST) as device:
        await device.update_status()
        device.show_sensors()


if __name__ == "__main__":
    asyncio.run(main())
```

The `DaikinFactory` automatically detects your device type and firmware version, creating the appropriate device instance.

### Control writes (BRP069)

`device.set()` on BRP069/BRP072C adapters:

* First reads `get_control_info`. If that answer lacks `pow`, `mode`, `stemp` or `shum` (AirBase: `shum` is optional), a `DaikinException` is raised and nothing is written.
* pydaikin never repeats a request: `set_control_info` is sent once and never retried by the transport, while other endpoints such as `set_led` keep the general transport retry. The only second write is the deliberate whole-degree fallback (see Target temperature step), which sends a different `stemp`. aiohttp itself may resend the identical request once if a reused keep-alive connection drops without an answer.
* A non-OK `ret` (e.g. `PARAM NG`) raises `DaikinCommandRejected` (with `.ret`), and HTTP 404 raises instead of counting as success. After a rejection the cache shows the state read before the write.
* After a timeout or another error the outcome is unknown: the state is read back (read only, transport retries included, at most 5 s). If that fails, the cache keeps the last read state without the requested `stemp` and is refetched on the next update.
* `set()` and `update_status()` are serialised per device, so a poll never runs in the middle of a write.

AirBase (BRP15B61) adapters only get the pre-read validation; their own `set()` keeps the previous write behaviour (lenient reply parsing, transport retries, no rollback, read-back or locking).

### Target temperature step (BRP069)

`device.target_temperature_step` starts optimistic at `0.5` on BRP069/BRP072C adapters and is learned from normal setpoint changes, without probing writes:

* A half-degree `set({'stemp': '23.5'})` that the adapter accepts is read back immediately; `target_temperature_step_status` becomes `"confirmed"`. If the device reports another number, `DaikinVerificationError` (with `requested` and `actual`) is raised; there is no delayed second read. Dry and fan mode have no effective setpoint: nothing is learned there, not even from a matching number, and a `PARAM NG` never falls back. Fan mode accepts and ignores `stemp` (read back `--`), which is not an error. In any other mode, `M`/`--` raises `DaikinVerificationError`. If the mode changed between write and read-back, nothing is learned.
* If the adapter answers `ret=PARAM NG` to a pure `stemp` change between 18 and 30 °C, the current setpoint is numeric (not `M`/`--`), and 0.5 °C has not been confirmed, the same request is retried once with only `stemp` rounded half up (23.5 → 24). The step becomes `1.0` (`"inferred"`) once 24 is read back; this is an inference, not proof for every mode. If the mode changed before that read-back, `set()` returns normally and nothing is learned. A warning is logged when the step first becomes inferred (later fallbacks log at debug level); set `device.whole_degree_fallback = False` to get the rejection as `DaikinCommandRejected` instead. The retry repeats the `pow`/`mode` of the original request, which were read just before; a remote or app change in that short window would be overwritten.
* Timeouts and other errors without a device answer never change the step (see Control writes).
* pydaikin does not persist the learned state. Consumers can store `target_temperature_step_status` and assign it back after creating the device; other values raise `ValueError`. `"inferred"` reports a 1 °C step, and `"confirmed"` disables the fallback. A stale `"inferred"` is corrected by the next accepted half degree, but a stale `"confirmed"` never heals: half degrees are then rejected with `DaikinCommandRejected` instead of falling back. Key a stored status by the adapter's MAC address and firmware version, so that a replaced adapter or a firmware update starts from `"unknown"`.

Other adapters report `1.0`.

## Firmware Version 2.8.0 Support

Firmware version 2.8.0 introduces a different API structure compared to earlier versions. PyDaikin automatically detects and handles this firmware version.

### API structure

Unlike the older CGI-based adapters (BRP069 family), firmware 2.8.0 exposes a single JSON endpoint, `POST /dsiot/multireq`:

* **Status reads** are batch requests containing four `op: 2` entries (indoor unit, outdoor unit, weekly energy and adapter info).
* **Writes** are `op: 3` entries that walk the `dgc_status` tree down to the parameter to change.

Full request/response examples are in [`docs/sample_requests/brp084/`](docs/sample_requests/brp084/README.md).

### Power semantics

The behaviour of `device.set(...)` was validated against the unit's behaviour (see `tests/test_daikin_brp084.py`):

* `device.set({})` turns the unit **on** (the Home Assistant toggle-switch path)
* `device.set({'mode': 'off'})` turns the unit **off**
* `device.set({'mode': 'cool'})` turns the unit **on** and switches mode
* `device.set({'stemp': 25.0})` sets the temperature only; a powered-off unit stays off

### Supported features

* **Comfort airflow, Econo, Outdoor-quiet and Powerful toggles** - Powerful and the trio (Comfort/Econo/Outdoor-quiet) are mutually exclusive, matching the remote's last-button-pressed-wins behaviour
* **Discrete vertical vane control** - `off`, `down` (floor) and `swing`
* **Swing** on the vertical and horizontal axes, per mode
* **Sensors** - indoor/outdoor temperature, humidity, compressor temperature, decoded indoor/outdoor model strings and adapter firmware/API version
* **Energy data** - daily runtime and weekly consumption
* **Sub-zero outdoor temperatures** - sensor values are decoded as little-endian signed hex, so negative readings are handled correctly
* **Auto mode without a setpoint** - some units (e.g. the Urusara X, model `W-SRTA322F`) only expose cool/hot setpoints and report no auto setpoint (`e_3001/p_1D`); the target temperature then degrades to `--` instead of failing `init()` (issue [#72](https://github.com/fredrike/pydaikin/issues/72))

**Confirmed working with:**

* FTKM20YVMA
* FTXM46WVMA
* FTXV80WVMA
* FTXA25C2V1BW
* FTXA50C2V1BW

If you have a device with firmware 2.8.0 that is not working correctly, please open an issue with your device model and debug logs.

## Unsupported Devices

The following device and firmware combinations are not currently supported:

* BRP069C4x with firmware version 2.0.0

## About

PyDaikin was originally created by Yari Adan and is currently maintained by Fredrik Erlandsson.