BCD (Beam Commuting Device) CORRECTION SUMMARY
======================================================================

Generated: 2026-01-26 14:11:15

PROCESSING PARAMETERS
----------------------------------------------------------------------
BCD Mode:              OUT_IN
Spectral Band:         LM
Spectral Resolution:   LOW
Extension Type:        OI_VIS2
Polynomial Order:      1

DATA PROCESSING
----------------------------------------------------------------------
Number of File Pairs:  4
Wavelength Range:      2.80 - 5.16 µm
Number of Channels:    118

FILTERING & VALIDATION
----------------------------------------------------------------------
Outlier Threshold:     1.5 σ
Correlated Flux Only:  False
Min Coherence Time:    5 ms
Wavelength Low:        3.20 µm
Wavelength High:       4.00 µm

BASELINE PAIRS
----------------------------------------------------------------------
Pair 1:  [2] U1-U3 ↔ [4] U2-U3
Pair 2:  [3] U1-U4 ↔ [5] U2-U4

SPECTRAL WINDOWS (for polynomial fits)
----------------------------------------------------------------------
Window 0: 3.20 - 4.00 µm
Window 1: 4.55 - 4.90 µm

OUTPUT FILES
----------------------------------------------------------------------
Corrections CSV:       bcd_OUT_IN_spectral_corrections.csv
Polynomial Coeffs CSV: bcd_OUT_IN_poly_coeffs.csv
Output Directory:      /Users/asoulain/Documents/Projet_MATISSE/MATISSE_MN_analysis/magic_outputs/MN_cal_selection_LM_noChop

BASELINES
----------------------------------------------------------------------
  [0] U3-U4
  [1] U2-U1
  [2] U1-U3
  [3] U1-U4
  [4] U2-U3
  [5] U2-U4

======================================================================
For more details, see the CSV files above.
======================================================================