SPROCLIB Tank Examples
==================================================
=== Simple Tank Examples ===

--- Single Tank ---
Tank created: Basic Storage Tank
Type: Tank

Tank specifications:
Total volume: 1000.0 L
Initial level: 50.0%
Initial volume: 500.0 L

Flow rates:
Inlet flow: 10.0 L/min
Outlet flow: 8.0 L/min
Net flow: 2.0 L/min
Time to fill: 250.0 minutes

--- Interacting Tanks ---
Tank system created: Two Tank System
Type: InteractingTanks

System specifications:
Tank 1 volume: 800.0 L (Level: 70.0%)
Tank 2 volume: 1200.0 L (Level: 30.0%)
Connection flow: 5.0 L/min

Current volumes:
Tank 1: 560.0 L
Tank 2: 360.0 L
Total liquid: 920.0 L

Simple tank examples completed successfully!

=== Comprehensive Tank Examples ===

--- Dynamic Level Control ---
Level Control Simulation:
Setpoint: 60.0%
Initial level: 40.0%
Tank volume: 2000.0 L

Time (min) Level (%)  Error    Controller   Flow In   
------------------------------------------------------------
0          43.0       20.0     20.0         20.0      
5          46.0       17.0     20.0         20.0      
10         49.0       14.0     20.0         20.0      
15         52.0       11.0     20.0         20.0      
20         55.0       8.0      20.0         20.0      
25         58.0       5.0      20.0         20.0      
30         61.0       2.0      20.0         20.0      
35         64.0       -1.0     20.0         20.0      
40         66.4       -4.0     17.7         17.7      
45         66.8       -6.4     9.7          9.7       
50         66.3       -6.8     5.6          5.6       
55         65.2       -6.3     3.8          3.8       
60         64.0       -5.2     3.3          3.3       

--- Multi-Tank Cascade System ---
Cascade System Configuration:
----------------------------------------------------------------------
Tank     Volume (L)   Initial Level (%)  Current Volume (L)
----------------------------------------------------------------------
Tank 1   500          80                 400.0             
Tank 2   750          60                 450.0             
Tank 3   1000         40                 400.0             
Tank 4   1250         20                 250.0             

Cascade Flow Simulation (steady state):
--------------------------------------------------
Tank 1: In = 12.0 L/min, Out = 13.0 L/min
Tank 2: In = 13.0 L/min, Out = 13.5 L/min
Tank 3: In = 13.5 L/min, Out = 13.7 L/min
Tank 4: In = 13.7 L/min, Out = 13.4 L/min

--- Heat Transfer Analysis ---
Heat Transfer Simulation:
Tank volume: 5.0 m�
Heating power: 50 kW
Initial temperature: 20.0�C
Ambient temperature: 15.0�C

Time (h)   Temp (�C)    Heat Loss (kW)  Net Heat (kW)  
------------------------------------------------------------
0.0        20.0         0.5             49.5           
0.5        20.0         0.5             49.5           
1.0        20.0         0.5             49.5           
1.5        20.0         0.5             49.5           
2.0        20.0         0.5             49.5           
2.5        20.0         0.5             49.5           
3.0        20.0         0.5             49.5           
3.5        20.0         0.5             49.5           
4.0        20.0         0.5             49.5           

--- Mixing and Residence Time Analysis ---
Mixing Tank Analysis:
Working volume: 3000.0 L
Flow rate: 150.0 L/min
Residence time: 20.0 minutes
Error running examples: 'charmap' codec can't encode character '\u207b' in position 24: character maps to <undefined>


STDERR:
----------------------------------------
Traceback (most recent call last):
  File "C:\htdocs\github\paramus-experiments\paramus-experiments\paramus\chemistry\process_control\examples\tank_examples.py", line 301, in main
    comprehensive_tank_examples()
    ~~~~~~~~~~~~~~~~~~~~~~~~~~~^^
  File "C:\htdocs\github\paramus-experiments\paramus-experiments\paramus\chemistry\process_control\examples\tank_examples.py", line 267, in comprehensive_tank_examples
    print(f"Turnover rate: {turnover_rate:.3f} min\u207b�")
    ~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
  File "C:\Python313\Lib\encodings\cp1252.py", line 19, in encode
    return codecs.charmap_encode(input,self.errors,encoding_table)[0]
           ~~~~~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^
UnicodeEncodeError: 'charmap' codec can't encode character '\u207b' in position 24: character maps to <undefined>