Metadata-Version: 2.5
Name: aiomarstek
Version: 0.2.5
Summary: Async client library for local Marstek devices
Project-URL: Homepage, https://github.com/MarstekEnergy/aiomarstek
Project-URL: Issues, https://github.com/MarstekEnergy/aiomarstek/issues
Author: Marstek
License-Expression: MIT
License-File: LICENSE
Keywords: asyncio,home-assistant,marstek,udp
Classifier: Development Status :: 3 - Alpha
Classifier: Framework :: AsyncIO
Classifier: Intended Audience :: Developers
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python :: 3
Classifier: Programming Language :: Python :: 3.11
Classifier: Programming Language :: Python :: 3.12
Classifier: Programming Language :: Python :: 3.13
Classifier: Typing :: Typed
Requires-Python: >=3.11
Provides-Extra: test
Requires-Dist: pytest-asyncio>=0.24; extra == 'test'
Requires-Dist: pytest>=8.0; extra == 'test'
Requires-Dist: ruff>=0.8; extra == 'test'
Description-Content-Type: text/markdown

# aiomarstek

[![PyPI](https://img.shields.io/pypi/v/aiomarstek.svg)](https://pypi.org/project/aiomarstek/)
[![Python](https://img.shields.io/pypi/pyversions/aiomarstek.svg)](https://pypi.org/project/aiomarstek/)
[![CI](https://github.com/MarstekEnergy/aiomarstek/actions/workflows/ci.yml/badge.svg)](https://github.com/MarstekEnergy/aiomarstek/actions/workflows/ci.yml)
[![License: MIT](https://img.shields.io/badge/License-MIT-blue.svg)](https://github.com/MarstekEnergy/aiomarstek/blob/main/LICENSE)

Async client library for local Marstek device communication.

`aiomarstek` contains the UDP protocol, command builder, discovery cache,
polling pause handling, and high-level status helpers used by the Home Assistant
Marstek integration. `hold_glitches` runs inside `get_device_status`, so every
consumer gets the same protection: a 0 % SOC reading right after a high level,
and a single dip of a lifetime energy counter, are held at their previous value
until they persist over a few polls (then accepted as real). Counters that do
persist are passed on, and the sensors expose them as `TOTAL_INCREASING`, for
which Home Assistant treats a lower reading as a meter reset.

## Installation

```bash
python -m pip install aiomarstek
```

## Example

```python
import asyncio

from aiomarstek import MarstekUDPClient


async def main() -> None:
    client = MarstekUDPClient()
    await client.async_setup()
    try:
        devices = await client.discover_devices()
        print(devices)
    finally:
        await client.async_cleanup()


asyncio.run(main())
```

## Units

Numeric status fields are normalized, so a consumer does not have to know which
interface reported a value. Every energy counter is in **Wh**, although the
reply scales differ per interface and per field:

| Reply | Counters | Scale |
| --- | --- | --- |
| `ES.GetStatus` | `total_pv_energy` | 0.01 kWh |
| `ES.GetStatus` | grid and load totals | Wh |
| `Bat.GetStatus` | `bat_total_*_energy` | 0.1 kWh |
| `Bat.GetStatus` | `backup_*_energy` | 0.001 kWh (i.e. Wh) |
| `EM.GetStatus` | CT `input_energy` / `output_energy` | 0.1 Wh |
| `Energy.GetData` | day, month and total charge/discharge | 0.01 kWh |

`FIELD_UNITS` in `aiomarstek/models.py` is the single source of truth: it records
the reply property name, the documented scale and the normalized unit of each
scaled field, and the parsers take their factor from it. The scales follow the
*Marstek Device Local API* Rev 4.0 field tables, cross-checked against a
VenusE 3.0. Two points where the document alone is misleading:

- `EM.GetStatus.input_energy` / `output_energy` still print `[Wh] (*0.1)` in
  Rev 4.0. They are read as 0.1 Wh, which reproduces the measured 230.68 kWh
  for a raw 2306800. `ES.GetMode` repeats the CT fields with the corrected
  `[0.1 Wh]` scale, but only documents them as valid in Auto and AI mode, so
  the library ignores that copy: `EM.GetStatus` is the single source of the CT
  fields (`ct_state`, phase/total power and the two energy counters).
- The `Energy.GetData` counters are grid-side energy, not battery throughput:
  `total_charge` equals `ES.GetStatus.total_grid_input_energy / 10` at the same
  instant. The battery-side totals are `battery_total_input_energy` /
  `battery_total_output_energy` from `Bat.GetStatus`.

Unscaled fields keep the unit the device reports: power in W, voltage in V,
current in A, `battery_soc` / `dod` / `battery_soh` in %, `battery_temperature`
in °C and the battery capacities in Wh.

## Security considerations

The protocol is unauthenticated: `build_command` emits only `id`, `method` and
`params`, and responses carry no token or signature either. The trust boundary
is therefore the network — any host that can reach a device's UDP port can send
it any command, and any host can answer a broadcast discovery request.

What the library does mitigate: with `verify_source_ip=True` (the default) a
unicast response whose source address does not match the device the request was
sent to is dropped, so another host cannot forge a status reply or fake a write
success. That says nothing about whether the device itself validates the
commands it receives — assume it does not until Marstek documents otherwise.

- Never expose the device UDP port (default `30000`) to untrusted networks or
  the internet; keep devices on a segment that only trusted hosts can reach.
- The client binds `0.0.0.0:<local_port>` (default `30000`) for replies;
  restrict inbound UDP on that port to the device addresses.
- Discovery accepts responses from any host, so treat discovery results as
  untrusted input.
- Debug logging records full request/response JSON and peer addresses; disable
  it after troubleshooting and scrub network identifiers before sharing logs.

## Development

```bash
python -m pip install -e ".[test]"
python -m pytest
python -m ruff check .
python -m build
```