Summary: Check bare-metal and GPU servers against NetBox before they go into service.
Author: Reza Iskandar Achmad
License-Expression: MIT
Project-URL: Repository, https://github.com/riskand/racklint
Keywords: redfish,bmc,netbox,commissioning,gpu,data-centre
Classifier: Development Status :: 3 - Alpha
Classifier: Environment :: Console
Classifier: Intended Audience :: System Administrators
Classifier: Operating System :: OS Independent
Classifier: Programming Language :: Python :: 3.12
Classifier: Programming Language :: Python :: 3.13
Classifier: Topic :: System :: Hardware
Classifier: Topic :: System :: Systems Administration
Classifier: Typing :: Typed
Requires-Python: >=3.12
Description-Content-Type: text/markdown
License-File: LICENSE
Requires-Dist: httpx>=0.28
Requires-Dist: pydantic>=2.9
Requires-Dist: pydantic-settings>=2.6
Requires-Dist: pyyaml>=6.0
Requires-Dist: rich>=13.9
Requires-Dist: typer>=0.15
Provides-Extra: dev
Requires-Dist: mypy>=1.13; extra == "dev"
Requires-Dist: pytest>=8.3; extra == "dev"
Requires-Dist: pytest-asyncio>=0.25; extra == "dev"
Requires-Dist: pytest-cov>=6.0; extra == "dev"
Requires-Dist: respx>=0.22; extra == "dev"
Requires-Dist: ruff>=0.8; extra == "dev"
Requires-Dist: types-pyyaml>=6.0; extra == "dev"
Provides-Extra: network
Requires-Dist: pygnmi>=0.8.15; extra == "network"
Dynamic: license-file

# racklint

**Check servers and switches against the inventory before they go into service.**

racklint is a commissioning validator for bare-metal and GPU clusters. It reads what each server reports through
its BMC over [Redfish](https://www.dmtf.org/standards/redfish), and what each switch reports over
[gNMI](https://gnmi.openconfig.net) with OpenConfig models, and compares that with what
[NetBox](https://netbox.dev) says should be there. Every mismatch is flagged: a wrong GPU count, a wrong serial
number, firmware not on the approved list, a missing NIC, a cable that lands on the wrong switch port.

You can use it in two ways: as the `racklint` command, or as a Python library.

## Why

When a rack is brought up, the question is not "what hardware is in it?" but "is the hardware in it what we
ordered and planned for?" Existing tools such as [netbox-sync](https://github.com/bb-Ricardo/netbox-sync) and
[netbox-agent](https://github.com/Solvik/netbox-agent) answer the first question: they read the hardware and
write it into NetBox, so NetBox ends up describing whatever was found.

racklint works the other way. NetBox holds the planned state and stays the source of truth. racklint checks the
hardware against it, changes nothing, and fails loudly on any difference. That makes it useful as a gate: a
device only moves to the next stage of bring-up once racklint passes it.

It is read-only. It sends only GET requests to NetBox and to the BMCs, and only gNMI Get requests to the
switches. The host OS does not need to be running.

## Install

```bash
pip install racklint
```

To check switches as well, install the `network` extra, which adds the gNMI client
([pygnmi](https://github.com/akarneliuk/pygnmi)):

```bash
pip install "racklint[network]"
```

racklint needs Python 3.12 or later. Without the extra, a plan that contains switches stops with a
configuration error that names the extra to install.

## Command line

### Settings

The command reads its settings from `RACKLINT_*` environment variables, or from a `.env` file in the working
directory.

| Setting | Default | Meaning |
|---|---|---|
| `RACKLINT_NETBOX_URL` | required | Base URL of NetBox, for example `https://netbox.example.net` |
| `RACKLINT_NETBOX_TOKEN` | required | NetBox API token |
| `RACKLINT_BMC_USERNAME` | required if the plan has servers | User name for every BMC |
| `RACKLINT_BMC_PASSWORD` | required if the plan has servers | Password for every BMC |
| `RACKLINT_BMC_PASSWORD_FILE` | unset | A file that holds the BMC password, instead of `RACKLINT_BMC_PASSWORD` |
| `RACKLINT_BMC_SCHEME` | `https` | `https` or `http` |
| `RACKLINT_BMC_VERIFY_TLS` | `true` | Verify BMC TLS certificates |
| `RACKLINT_BMC_CA_BUNDLE` | unset | CA bundle file used to verify BMC certificates |
| `RACKLINT_SWITCH_USERNAME` | required if the plan has switches | User name for every switch |
| `RACKLINT_SWITCH_PASSWORD` | required if the plan has switches | Password for every switch |
| `RACKLINT_SWITCH_PASSWORD_FILE` | unset | A file that holds the switch password, instead of `RACKLINT_SWITCH_PASSWORD` |
| `RACKLINT_GNMI_PORT` | `57400` | The gNMI port of every switch |
| `RACKLINT_SWITCH_VERIFY_TLS` | `true` | Verify switch TLS certificates. Needs `RACKLINT_SWITCH_CA_BUNDLE` |
| `RACKLINT_SWITCH_CA_BUNDLE` | unset | CA bundle file used to verify switch certificates |
| `RACKLINT_CONCURRENCY` | `16` | Devices read at once |
| `RACKLINT_BMC_CONCURRENCY` | `4` | Requests in flight to one BMC |

racklint builds a reader only for the kinds of device in the plan. A run that checks only switches needs no BMC
settings, and a run that checks only servers needs no switch settings.

A token that starts with `nbt_` (NetBox 4.5 and later) is sent as a bearer token. Any other token is sent as a
legacy `Token`.

#### Passwords from files

A password in an environment variable can leak into process listings and CI logs. Instead of
`RACKLINT_BMC_PASSWORD` or `RACKLINT_SWITCH_PASSWORD`, you can set `RACKLINT_BMC_PASSWORD_FILE` or
`RACKLINT_SWITCH_PASSWORD_FILE` to the path of a file that holds the password. A final newline is ignored.
Setting both the password and its file is an error, and so is a file that cannot be read or is empty. The error
names the file, never its content.

racklint reads the file at the start of every run. This suits a secret manager that mounts secrets as files, such
as Docker or Kubernetes secrets or Vault Agent: when the manager rotates a password by rewriting the file,
racklint uses the new password on its next run, and no secret sits in the environment. One set of credentials
still applies to every BMC and one to every switch.

### Run a check

```bash
racklint check --rack R01
racklint check --device gpu-01 --device gpu-02
```

Pass exactly one of `--rack` and `--device`. A run checks the servers and switches among the devices and prints
one report for all of them.

| Option | Meaning |
|---|---|
| `--rack NAME` | Check every device in this NetBox rack |
| `--site SLUG` | Site slug. Needed only if the rack name exists in several sites |
| `--device NAME` | Check this device. Repeat for more |
| `--baseline PATH` | Firmware baseline file. Optional. Overrides the firmware rules planned in NetBox |
| `--format table\|json` | Output format. Default `table` |
| `--concurrency N` | Devices to read at once. Overrides `RACKLINT_CONCURRENCY` |
| `--ca-bundle PATH` | CA bundle for BMC certificates. Overrides `RACKLINT_BMC_CA_BUNDLE` |
| `--insecure` | Do not verify BMC certificates. Overrides `RACKLINT_BMC_VERIFY_TLS` |

`--ca-bundle` and `--insecure` apply to BMCs only. Switches have their own settings, because they usually sit in
a different PKI.

The servers are read first and then the switches, each kind with up to `--concurrency` devices at once.

### Firmware rules

The approved firmware versions live in NetBox, in the `firmware` list of the `racklint` config context, next to
the rest of the plan. Assign the context to the device type, so every device of that type gets the rules:

```yaml
racklint:
  firmware:
    - match: "BMC"
      approved: ["1.4.0"]
    - match: "GPU_*"
      approved: ["96.00.89.00.01"]
```

Each `match` is a case-sensitive glob on the `Id` of a firmware item the device reports. Versions must be
quoted strings. A rule must match at least one item, and every item it matches must run an approved version. A
switch reports its OS as the firmware item `OS`, so the rule `match: "OS"` covers a switch's OS version.

A device whose type has no rules fails with `no firmware baseline for device type <slug>`.

`--baseline` is an override. It names a YAML file with the approved versions for each device type, and when you
give it, racklint uses the file's rules for every device and ignores the rules in the config contexts. It
replaces the rules and never merges with them. Use it to check against a list kept in a repository, or to keep
using a v0.1 baseline file unchanged.

```yaml
device_types:
  gpu-node-h100:             # NetBox device-type slug
    - match: "BMC"
      approved: ["1.4.0"]
    - match: "GPU_*"
      approved: ["96.00.89.00.01"]
```

### Exit codes

| Code | Meaning |
|---|---|
| `0` | Every device passed |
| `1` | At least one device failed, or could not be read |
| `2` | Usage or configuration error: bad arguments, invalid settings or baseline, missing credentials for a kind of device in the plan, NetBox unreachable or returning an error, rack or device not found |

Use the exit code to gate a pipeline.

### Output

The table has one row per device and one line per reason, then a summary:

```console
┏━━━━━━┳━━━━━━━━┳━━━━━━━━━━━━┳━━━━━━━━┳━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┓
┃ Node ┃ Kind   ┃ Address    ┃ Status ┃ Reasons                                ┃
┡━━━━━━╇━━━━━━━━╇━━━━━━━━━━━━╇━━━━━━━━╇━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━━┩
│ n01  │ server │ 192.0.2.11 │ PASS   │                                        │
│ n02  │ server │ 192.0.2.12 │ PASS   │                                        │
│ n03  │ server │ 192.0.2.13 │ FAIL   │ gpu: 7 found, 8 planned                │
│ n04  │ server │ 192.0.2.14 │ PASS   │                                        │
│ n05  │ server │ 192.0.2.15 │ FAIL   │ memory: 31 DIMMs (1984 GiB), 32        │
│      │        │            │        │ planned (2048 GiB)                     │
│      │        │            │        │ firmware: BMC 1.3.2 not in approved    │
│      │        │            │        │ [1.4.0]                                │
│ n06  │ server │ 192.0.2.16 │ PASS   │                                        │
└──────┴────────┴────────────┴────────┴────────────────────────────────────────┘
4 passed, 2 failed, 0 errored
```

The kind is `server` or `switch`. The address is where racklint read the device: a server's BMC address, or a
switch's management address. A device has status `PASS`, `FAIL` or `ERROR`. `ERROR` means racklint could not
read the device (a connection failure after retries, a timeout, a rejected login or an invalid reply). No
checks run for that device, and the reason is the error.

With `--format json` the output is the report as JSON. This is one failing server:

```json
{
  "schema_version": 2,
  "results": [
    {
      "node": "n03",
      "kind": "server",
      "address": "192.0.2.13",
      "status": "fail",
      "findings": [
        {
          "check": "gpu",
          "message": "7 found, 8 planned"
        }
      ],
      "error": null
    }
  ]
}
```

`status` is `pass`, `fail` or `error`. `error` is set only when the status is `error`.

## Python library

The names exported from `racklint` (its `__all__`) are the public API. Anything else may change before 1.0. The
package ships type hints (`py.typed`). The names fall into these groups:

| Group | Names |
|---|---|
| State | `Kind`, `PlanContext`, `ExpectedNode`, `PlannedInterface`, `HardwareSpec`, `GpuSpec`, `MemorySpec`, `ActualNode`, `Gpu`, `Dimm`, `NetworkPort`, `ExpectedSwitch`, `PlannedLink`, `ActualSwitch`, `LldpNeighbour`, `FirmwareItem` |
| Verdict | `Report`, `NodeResult`, `Finding`, `Status` |
| Running checks | `check_nodes`, `iter_results`, `ActualReader`, `Check`, `server_checks`, `switch_checks`, `SerialCheck`, `GpuCheck`, `MemoryCheck`, `NicCheck`, `FirmwareCheck`, `LinkCheck` |
| Sources | `NetBoxSource`, `netbox_client`, `RedfishReader`, `BmcAccess`, `GnmiReader`, `GnmiAccess`, `GnmiClient`, `FirmwareBaseline`, `FirmwareRule` |
| Errors | `RacklintError`, `BaselineError`, `NetBoxError`, `InventoryError`, `RedfishError`, `GnmiError` |

The library is async and does not read `RACKLINT_*` settings: you pass it explicit objects. `NetBoxSource`
returns both kinds of device, `ExpectedNode` for a server and `ExpectedSwitch` for a switch. You split them,
read each kind with its own reader and run its own checks: `server_checks()` for servers, `switch_checks()` for
switches. This example reads the plan for rack R01 from NetBox, checks the servers and the switches, and prints
a verdict per device. It takes its connection details from the environment.

```python
import asyncio
import os
from pathlib import Path

from racklint import (
    BmcAccess,
    ExpectedNode,
    ExpectedSwitch,
    GnmiAccess,
    GnmiReader,
    NetBoxSource,
    RedfishReader,
    check_nodes,
    netbox_client,
    server_checks,
    switch_checks,
)


async def main() -> None:
    async with netbox_client(os.environ["NETBOX_URL"], os.environ["NETBOX_TOKEN"]) as client:
        nodes = await NetBoxSource(client).rack("R01")
    servers = [node for node in nodes if isinstance(node, ExpectedNode)]
    switches = [node for node in nodes if isinstance(node, ExpectedSwitch)]

    bmc = BmcAccess(username=os.environ["BMC_USERNAME"], password=os.environ["BMC_PASSWORD"])
    switch = GnmiAccess(
        username=os.environ["SWITCH_USERNAME"],
        password=os.environ["SWITCH_PASSWORD"],
        ca_bundle=Path("switch-ca.pem"),
    )
    server_report = await check_nodes(servers, RedfishReader(bmc), server_checks(), concurrency=16)
    switch_report = await check_nodes(switches, GnmiReader(switch), switch_checks(), concurrency=16)

    results = (*server_report.results, *switch_report.results)
    for result in results:
        print(result.node, result.kind, result.status, [finding.message for finding in result.findings])
    print("all passed" if server_report.passed and switch_report.passed else "not all passed")


asyncio.run(main())
```

`check_nodes` returns a `Report` with the results in the order of the devices you pass. To act on each result as
soon as it is ready, for live progress, loop over `iter_results` instead. It takes the same arguments and yields
`NodeResult`s in the order they finish:

```python
import asyncio
import os

from racklint import (
    BmcAccess,
    ExpectedNode,
    NetBoxSource,
    RedfishReader,
    iter_results,
    netbox_client,
    server_checks,
)


async def main() -> None:
    async with netbox_client(os.environ["NETBOX_URL"], os.environ["NETBOX_TOKEN"]) as client:
        nodes = await NetBoxSource(client).devices(["gpu-01", "gpu-02"])
    servers = [node for node in nodes if isinstance(node, ExpectedNode)]

    access = BmcAccess(username=os.environ["BMC_USERNAME"], password=os.environ["BMC_PASSWORD"])
    async for result in iter_results(servers, RedfishReader(access), server_checks(), concurrency=16):
        print(result.node, result.status)


asyncio.run(main())
```

`NetBoxSource` raises `NetBoxError` and `FirmwareBaseline.load` raises `BaselineError`; both are subclasses of
`RacklintError`. A device that cannot be read does not raise: its result gets status `error`. Reading a switch
needs the `network` extra, and without it `GnmiReader` raises `RacklintError`; the gNMI names are importable
either way.

`FirmwareBaseline.applied_to(node)` returns the node with the baseline's rules for its device type in place of
its planned rules, as `--baseline` does for every device. A `FirmwareBaseline` can also be built from a dict
with `FirmwareBaseline.model_validate`, so an application can keep the baseline in its own database.

The NetBox source is optional. A NetBox plugin runs inside NetBox, so it can build `ExpectedNode`s and
`ExpectedSwitch`es from the Django ORM instead of the REST API, then call `asyncio.run(check_nodes(...))` from a
background job, which is synchronous code.

## What it checks

| Check | Applies to | Fails when | Example reason |
|---|---|---|---|
| Serial | servers, switches | The device's serial matches none of the serials the device reports | `serial: expected SN-R01-03, device reports SN-R01-30` |
| GPU | servers | The GPU count differs, or a GPU's model differs from the planned model | `gpu: 7 found, 8 planned` |
| Memory | servers | The enabled DIMM count or the total capacity differs | `memory: 31 DIMMs (1984 GiB), 32 planned (2048 GiB)` |
| NIC | servers | A planned MAC address is not reported, or fewer ports are reported than interfaces are planned | `nic: eth2 (a0:88:c2:00:03:03) not found` |
| Firmware | servers, switches | The device type has no rules, a rule matches no firmware item, or a matched item's version is not approved | `firmware: BMC 1.3.2 not in approved [1.4.0]` |
| Link | switches | A planned switch-to-switch link is not seen, or is seen on the wrong far end; a port with no planned cable sees a neighbour; or a planned link cannot be checked | `link: ethernet-1/1 expected spine1 ethernet-1/3, sees spine1 ethernet-1/4` |

A device passes only if every check passes. Firmware items that match no rule are ignored, and so are reported
ports beyond the plan.

If NetBox lacks a value a check needs, the device fails with `not planned in NetBox: <item>`. A device with no
address to read it at fails with that reason alone: `BMC address` for a server, `management address` for a
switch.

### What NetBox must hold

For a server:

| Item | Where racklint reads it |
|---|---|
| Serial | The device's `serial` field |
| BMC address | The device's out-of-band IP (`oob_ip`). The prefix length is dropped |
| Device type | The device type's slug |
| NICs | The device's physical interfaces that are not management-only. A MAC address is compared if the interface has a primary MAC; without one, racklint only counts the port |
| GPU and memory | The `racklint` key of the device's config context |
| Firmware rules | The `firmware` list in the `racklint` key of the config context, unless `--baseline` is given |

Assign the config context to the device type, so every device of that type gets it:

```yaml
racklint:
  gpu:    {count: 8, model: "NVIDIA H100 80GB HBM3"}
  memory: {dimm_count: 32, total_gib: 2048}
  firmware:
    - {match: "BMC", approved: ["1.4.0"]}
```

An invalid `racklint` config context is a configuration error and stops the run with exit code `2`.

On the BMC side, racklint starts at `/redfish/v1` and follows the links the service returns. It hardcodes no
vendor paths. It reads systems, processors, memory, network adapters and the firmware inventory. It uses HTTP
Basic authentication on every request and opens no Redfish sessions. It makes up to three attempts at a
request that fails with a connection error, a timeout, HTTP 5xx or 429, and uses a connect timeout of 5
seconds and a read timeout of 15 seconds. A refused login is never retried, because another try with a wrong
or just-rotated password could lock the account.

## Switches

A switch is a device whose type has `kind: switch` in its config context. The default kind is `server`.
Assign the context to the switch's device type:

```yaml
racklint:
  kind: switch
  firmware:
    - {match: "OS", approved: ["v26.7.2-519-g94fbd638fa8"]}
```

For a switch, racklint reads these from NetBox:

| Item | Where racklint reads it |
|---|---|
| Serial | The device's `serial` field |
| Management address | The device's out-of-band IP (`oob_ip`), or its primary IP (`primary_ip`) if there is no out-of-band IP |
| Firmware rules | The `firmware` list in the config context, unless `--baseline` is given. The OS is the rule `match: "OS"` |
| Planned links | The device's physical interfaces that are not management-only and whose cable has status `planned` or `connected` |

It reads these from the switch, over gNMI with OpenConfig models:

| Item | OpenConfig source |
|---|---|
| Serial | `state/serial-no` of the `/components/component` of type `CHASSIS` |
| OS version | `state/software-version` of the first component, in the order `OPERATING_SYSTEM`, `CONTROLLER_CARD`, `CHASSIS`, that reports one. It is the firmware item `OS` |
| LLDP neighbours | `system-name`, `port-id`, `port-id-type` and `port-description` of each neighbour on `/lldp/interfaces` |

The OS version is compared exactly, as firmware is: the approved string is what the switch reports, build suffix
included.

racklint connects to each switch on `RACKLINT_GNMI_PORT` with `RACKLINT_SWITCH_USERNAME` and
`RACKLINT_SWITCH_PASSWORD`. To verify the switch's TLS certificate it needs a CA bundle in
`RACKLINT_SWITCH_CA_BUNDLE`, because pygnmi cannot use the system trust store. Set
`RACKLINT_SWITCH_VERIFY_TLS=false` to accept any certificate instead. Requests are retried like Redfish
requests, up to three attempts, so a switch that is still starting does not show as an error, but a refused
login is not retried.

### The cabling rule

`LinkCheck` compares the planned cables of a switch with what the switch sees over LLDP. It checks a planned link
when the far end is a switch. Servers send no LLDP while no OS is running, so a link to a device planned as a
server is left out. The far end is the interface NetBox traces the cable to, through patch panels; where NetBox
has traced no path, it is the cable's own far end when that is an interface. A switch's links into another rack
are checked from this switch's side, and the far switch need not be part of the run.

A link matches when the LLDP neighbour on the local port is the planned far end:

- the neighbour's `system-name` equals the far device's NetBox name, or its short form before the first dot
  (switches often report an FQDN), and
- its `port-id` or `port-description` equals the far interface's NetBox name (some vendors put a MAC address
  in `port-id`).

The findings:

```text
link: ethernet-1/1 expected spine1 ethernet-1/1, sees spine1 ethernet-1/2
link: ethernet-1/3 expected spine1 ethernet-1/3, no LLDP neighbour
link: ethernet-1/5 not planned in NetBox, sees spine1 ethernet-1/4
link: ethernet-1/6 cannot be checked: spine2 has no racklint config context
link: ethernet-1/7 cannot be checked: its cable does not reach an interface in NetBox
```

A planned link is never dropped silently. If the far device has no `racklint` config context, so racklint does
not know its kind, or the cable does not reach an interface in NetBox, the link is reported as one that cannot be
checked. A port with no planned cable that sees any neighbour is a finding: the cable is there, but not in the
plan. Management ports are never considered, because switches see each other on them.

NetBox interface names must match the switch's own interface names, for example `ethernet-1/1`.

## Try it without hardware

[`examples/no-hardware/`](examples/no-hardware) is a Docker Compose stack with a real NetBox and six mock BMCs,
two of them built wrong on purpose. One command checks the rack, and the summary line is
`4 passed, 2 failed, 0 errored`. With `--profile fabric` it also starts three SR Linux leaves and a spine with
containerlab, and the same command checks nine devices: `5 passed, 4 failed, 0 errored`. See its README for the
steps and what is planted.

## Limitations

- GPUs are found only as Redfish `Processors` with `ProcessorType == "GPU"`. A BMC that exposes GPUs another way
  shows zero GPUs.
- One set of credentials applies to every BMC in a run, and one to every switch.
- Switches are checked for serial, OS version and switch-to-switch cabling. Optics, the hardware model, the
  cabling of BMC management ports and the cabling of servers' data ports are not checked.
- OpenConfig coverage differs by vendor and version. racklint reads the models above and is tested only against
  Nokia SR Linux. The reader in `racklint.gnmi` is the one place to extend.
- Read-only by design. racklint reports differences and never fixes them in NetBox or on a device.

## Changes in 0.2

New: switches, the `LinkCheck`, firmware rules in NetBox's config context, and password files. `--baseline` is
now optional, and the BMC credentials are needed only when the plan contains servers.

These changes break v0.1 users; racklint allows breaking changes before 1.0:

- **JSON report:** `schema_version` is `2`. Each result's `bmc_address` is now `address`, and each result gains
  `kind`. The table gains the Kind and Address columns.
- **Firmware rules:** they come from NetBox first. To keep a v0.1 baseline file working, pass it with
  `--baseline`; it overrides the rules in NetBox.
- **Library:** `default_checks(baseline)` is replaced by `server_checks()` and `switch_checks()`.
  `FirmwareCheck` takes no argument and reads the rules from the node. `NetBoxSource.rack()` and `devices()`
  return servers and switches. `NodeResult` changes like the JSON.
- **Messages:** the serial check says `device reports` instead of `BMC reports`, because it serves switches too.

## Related work

| Project | What it does |
|---|---|
| [bb-Ricardo/netbox-sync](https://github.com/bb-Ricardo/netbox-sync) | Syncs VMware and Redfish sources into NetBox |
| [Solvik/netbox-agent](https://github.com/Solvik/netbox-agent) | Agent on each server that pushes hardware into NetBox |
| [bb-Ricardo/check_redfish](https://github.com/bb-Ricardo/check_redfish) | Monitoring plugin for component health over Redfish |
| OpenStack Ironic, Metal3, MAAS, Warewulf | Full provisioning platforms with BMC inspection |

racklint is smaller than any of these and does one thing: it compares the hardware with NetBox's plan and
reports the differences.

## License

[MIT](LICENSE)