# The certificate should run for every bridge change
# The setup will include 1 tested device + 1 tester connected with UART or remote GW
# Run command example with COM PORT connection:
# python certificate_cli.py --tester SIM --dut <XXXXXXXXXXXX> --tl certificate_sanity_test_list.txt --port <COM_PORT> -vs <path_to_validation_schema_file>
# Run command example with remote GW connection:
# python certificate_cli.py --tester <GWYYYYYYYYYYYY> --dut <XXXXXXXXXXXX> --tl certificate_sanity_test_list.txt -vs <path_to_validation_schema_file>

# ------------- edge_mgmt -------------
edge_mgmt/periodic_msgs_test
edge_mgmt/action_gw_hb_test
edge_mgmt/action_blink_test
edge_mgmt/action_send_hb_test
edge_mgmt/action_get_battery_sensor_test
edge_mgmt/action_get_pof_data_test
edge_mgmt/action_get_module_test
edge_mgmt/action_reboot_test
edge_mgmt/action_restore_defaults_test

# ------------- energy2400 -------------
energy2400/pattern_test ENERGY_PATTERN_2_4_CHANNEL_37 ENERGY_PATTERN_2_4_CHANNEL_39 ENERGY_PATTERN_2_4_FREQ_2454
energy2400/output_power_test OUTPUT_POWER_2_4_MAX_MINUS_14 OUTPUT_POWER_2_4_MAX_MINUS_10 OUTPUT_POWER_2_4_MAX_MINUS_7 OUTPUT_POWER_2_4_MAX_MINUS_6 OUTPUT_POWER_2_4_MAX_MINUS_3 OUTPUT_POWER_2_4_MAX_MINUS_3 OUTPUT_POWER_2_4_MAX_MINUS_2
energy2400/duty_cycle_test 1 50 75
energy2400/signal_indicator_test rx_tx
energy2400/signal_indicator_ble5_test rx_tx

# ------------- energy_sub1g -------------
energy_sub1g/pattern_test SUB1G_ENERGY_PATTERN_NO_ENERGIZING SUB1G_ENERGY_PATTERN_FCC_HOPPING SUB1G_ENERGY_PATTERN_SINGLE_TONE_917500 SUB1G_ENERGY_PATTERN_NZ_HOPPING
energy_sub1g/duty_cycle_test 15 20 40 0

# ------------- datapath -------------
datapath/aging_test low_pacer
datapath/rssi_threshold_test -80
datapath/pattern_test DATAPATH_PATTERN_38_38_39 DATAPATH_PATTERN_EU_PATTERN DATAPATH_PATTERN_EXTENDED_ADV DATAPATH_PATTERN_EXTENDED_ADV_38_39
datapath/tx_repetition_test 4
datapath/output_power_test OUTPUT_POWER_2_4_MAX_MINUS_14 OUTPUT_POWER_2_4_MAX_MINUS_10 OUTPUT_POWER_2_4_MAX_MINUS_7 OUTPUT_POWER_2_4_MAX_MINUS_6 OUTPUT_POWER_2_4_MAX_MINUS_3 OUTPUT_POWER_2_4_MAX_MINUS_2
datapath/event_test new_tag_event_seconds temp_event
datapath/event_ble5_test new_tag_event_seconds
datapath/pkt_filter_ble5_test PKT_FILTER_TEMP_PKT
datapath/pkt_filter_gen3_test PKT_FILTER_TEMP_PKT
datapath/pkt_filter_ble5_chl21_test PKT_FILTER_TEMP_AND_ADVANCED_PKTS
datapath/pkt_filter_brg2gw_ext_adv_test RX_CHANNEL_38
datapath/rx_channel_test RX_CHANNEL_38 RX_CHANNEL_10_500K RX_CHANNEL_HOPPING_37_10
datapath/rx_rate_gen2_test min_value
datapath/num_of_tags_test 500

# ------------- pwr_mgmt -------------
pwr_mgmt/pwr_mgmt_test

# ------------- calibration -------------
calibration/output_power_test OUTPUT_POWER_2_4_MAX_MINUS_14 OUTPUT_POWER_2_4_MAX_MINUS_10 OUTPUT_POWER_2_4_MAX_MINUS_7 OUTPUT_POWER_2_4_MAX_MINUS_6 OUTPUT_POWER_2_4_MAX_MINUS_3 OUTPUT_POWER_2_4_MAX_MINUS_2
calibration/interval_test 25 50
calibration/pattern_test CALIBRATION_PATTERN_38_38_39

# ------------- sensors -------------
sensors/ext_sensor_test snsr0_no_scrmbl_snsr1_scrmbl_snsr2_scrmbl

# ------------- cloud_connectivity -------------
cloud_connectivity/uplink_test mgmt_pkt pixels_pkt
cloud_connectivity/downlink_test
cloud_connectivity/uplink_ext_adv_test
cloud_connectivity/reboot_test
cloud_connectivity/stress_test 100 222
cloud_connectivity/ext_adv_stress_test 20 100
cloud_connectivity/acl_test deny
cloud_connectivity/acl_ext_adv_test allow